The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, t...The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, the graph fitting technique is applied with some mathematical and computational tools based on the actual values of the years 2009 up to 2012 considering the lower values, the higher values and the average values of the annual maximum loads for Kingdom of Bahrain. For the three scenarios, the models are obtained by curve fitting technique. As well, the model of actual loads is obtained finally which has mostly the closest values obtained.展开更多
This paper presents practical distribution system equipment models such as various distributed generators, voltage regulators, and loads for fast three phase unbalanced load flow calculation in distribution systems. T...This paper presents practical distribution system equipment models such as various distributed generators, voltage regulators, and loads for fast three phase unbalanced load flow calculation in distribution systems. The method can calculate voltage and current of distribution systems, in which distributed generators are introduced. The calculation time of the proposed method is about 40 times faster than that of the Newton-Raphson method. Moreover, an introduction effect evaluation tool for distributed generators using the proposed three phase unbalanced load flow calculation is presented. It provides various functions such as a power system network diagram creation function and a voltage profile chart display function. Therefore, the introduction effect evaluation of distributed generators in distribution systems can be evaluated quite easily.展开更多
文摘The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, the graph fitting technique is applied with some mathematical and computational tools based on the actual values of the years 2009 up to 2012 considering the lower values, the higher values and the average values of the annual maximum loads for Kingdom of Bahrain. For the three scenarios, the models are obtained by curve fitting technique. As well, the model of actual loads is obtained finally which has mostly the closest values obtained.
文摘This paper presents practical distribution system equipment models such as various distributed generators, voltage regulators, and loads for fast three phase unbalanced load flow calculation in distribution systems. The method can calculate voltage and current of distribution systems, in which distributed generators are introduced. The calculation time of the proposed method is about 40 times faster than that of the Newton-Raphson method. Moreover, an introduction effect evaluation tool for distributed generators using the proposed three phase unbalanced load flow calculation is presented. It provides various functions such as a power system network diagram creation function and a voltage profile chart display function. Therefore, the introduction effect evaluation of distributed generators in distribution systems can be evaluated quite easily.