This study examines the state of liveability in emerging urban centers of Ago-lwoye and Ijebu-Igbo in Ogun State. The study used primary and secondary data. Both descriptive and inferential statistical techniques were...This study examines the state of liveability in emerging urban centers of Ago-lwoye and Ijebu-Igbo in Ogun State. The study used primary and secondary data. Both descriptive and inferential statistical techniques were used to analyze research questions that bother on urban liveability. Results of the analyses show that in the two urban centres the following are not in very good condition: neighborhood road quality, garbage collection, state of cleanliness, street light, state of security, pollution, water supply, drainage system, and power supply. Most of the residents are not satisfied with the state of liveability in Ago-Iwoye and Ijebu-Igbo towns. Statistical test result shows among others that there is no significant variation in the level of urban dwellers' satisfaction with their neighbourhood condition. In order to improve urban liveability in the two urban centres, government should provide all necessary infrastructural facilities and services. While roads are to be improved and maintained, electricity and water supply should be provided. Community associations should also be encouraged. They should be more involved in activities that will improve liveability in the urban centre. They should constitute themselves as pressure groups, working on the government to improve the liveability of the urban centre.展开更多
Special interest in current interruptions is dedicated to the processes close to the current zero instant, the so-called interaction region, which determines the circuit breakers' performance. The quantities of inter...Special interest in current interruptions is dedicated to the processes close to the current zero instant, the so-called interaction region, which determines the circuit breakers' performance. The quantities of interest in this region are the distribution of temperature, density and pressure, velocity and gas mass flow along the electric arc axis, as well as the distribution of electric stress between contacts Calculation of steady SF_6 gas flow through the nozzle of a 420 kV circuit breaker at the current zero instant, for different arcing durations, was carried out using a commercial CFD (computational fluid dynamics) simulation tool. The calculation results were used to get insight into improvement possibilities of the SF_6 gas flow model used in the software for computer simulation of HV (high-voltage) circuit breakers. Electric field calculation results were performed for the same 420 kV circuit breaker, in order to estimate the breakdown voltage at the current zero instant.展开更多
文摘This study examines the state of liveability in emerging urban centers of Ago-lwoye and Ijebu-Igbo in Ogun State. The study used primary and secondary data. Both descriptive and inferential statistical techniques were used to analyze research questions that bother on urban liveability. Results of the analyses show that in the two urban centres the following are not in very good condition: neighborhood road quality, garbage collection, state of cleanliness, street light, state of security, pollution, water supply, drainage system, and power supply. Most of the residents are not satisfied with the state of liveability in Ago-Iwoye and Ijebu-Igbo towns. Statistical test result shows among others that there is no significant variation in the level of urban dwellers' satisfaction with their neighbourhood condition. In order to improve urban liveability in the two urban centres, government should provide all necessary infrastructural facilities and services. While roads are to be improved and maintained, electricity and water supply should be provided. Community associations should also be encouraged. They should be more involved in activities that will improve liveability in the urban centre. They should constitute themselves as pressure groups, working on the government to improve the liveability of the urban centre.
文摘Special interest in current interruptions is dedicated to the processes close to the current zero instant, the so-called interaction region, which determines the circuit breakers' performance. The quantities of interest in this region are the distribution of temperature, density and pressure, velocity and gas mass flow along the electric arc axis, as well as the distribution of electric stress between contacts Calculation of steady SF_6 gas flow through the nozzle of a 420 kV circuit breaker at the current zero instant, for different arcing durations, was carried out using a commercial CFD (computational fluid dynamics) simulation tool. The calculation results were used to get insight into improvement possibilities of the SF_6 gas flow model used in the software for computer simulation of HV (high-voltage) circuit breakers. Electric field calculation results were performed for the same 420 kV circuit breaker, in order to estimate the breakdown voltage at the current zero instant.