期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于电阻率的混凝土裂缝测量方法 被引量:15
1
作者 艾亿谋 杜成斌 居发亮 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2008年第2期289-292,共4页
基于四探针电阻率测量技术,依据试验测得的混凝土表观电阻率变化确定裂缝位置.在考虑到干燥环境、潮湿环境和输入电流方向对裂缝导电能力影响的前提下,采用数值模拟技术探讨了表观电阻率随裂缝深度的变化规律,并将实际裂缝简化为等效裂... 基于四探针电阻率测量技术,依据试验测得的混凝土表观电阻率变化确定裂缝位置.在考虑到干燥环境、潮湿环境和输入电流方向对裂缝导电能力影响的前提下,采用数值模拟技术探讨了表观电阻率随裂缝深度的变化规律,并将实际裂缝简化为等效裂缝,进而提出裂缝等效电路和等效电阻的方法,研究了表观电阻率与裂缝密实度的关系.结果表明,依据电阻率测量方法可以准确地找出裂缝位置,裂缝深度和密实度与表观电阻率变化有较好的相关性;在干燥环境下,输入电流方向垂直于裂缝时表观电阻率随着裂缝深度或裂缝等效电阻率的增加而增大,输入电流方向平行于裂缝时表观电阻率随裂缝深度或裂缝等效电阻率的增加而减小;在潮湿环境下,输入电流方向垂直于裂缝时表观电阻率不随裂缝深度或裂缝等效电阻率的变化而改变,输入电流方向平行于裂缝时表观电阻率随裂缝深度或裂缝等效电阻率的增加而减小. 展开更多
关键词 电阻率测量技术 表观电阻率 裂缝深度 裂缝密实度 混凝土结构 数值模拟
下载PDF
Automated dual source systems for measurement of DC resistance standards
2
作者 Rasha S M Ali M Helmy A Raouf 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第2期109-115,共7页
A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratori... A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratories without cryogenic current comparators(CCC)or direct current comparators(DCC)bridges.Behavior of this bridge is evaluated by comparing its measured values with the unknown resistor values obtained by another method.The accuracy of the introduced bridge is in the level of 10-5 for the 1 mΩresistor,and in the level of 10-4 for the 10 mΩ,100 mΩand 1Ωresistors.Moreover,a dual voltage sources system for the measurement of DC standard resistors from 1 kΩto 100 MΩis also presented.In this system,a modification is made on the modified Wheatstone bridge to evaluate its performance by adding another digital multimeter to measure the ratio between the unknown and the standard resistors simultaneously.This bridge is verified by comparing the measured values of 10 kΩresistor obtained by the two methods with its actual value.The bridge accuracy is in the level of 10-6 except for the 1 kΩresistor,and the bridge asymmetry is also evaluated.It is found the asymmetry is in the level of 10-6 for the resistors from 10 kΩto 100 MΩand in the level of 10-5 for 1 kΩresistors.The introduced bridges operations are controlled by LabVIEW programs designed specially for this purpose,and the expanded uncertainty is also evaluated for all measurement results. 展开更多
关键词 direct current comparators voltage null detector modified Wheatstone bridge ratio technique resistance measurements UNCERTAINTY
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部