考虑不间断电源储能的数据中心电-冷联供系统优化运行 被引量:14
1
作者 陈璟 杨洪明 邓友均 《电力科学与技术学报》 CAS 北大核心 2019年第3期129-135,共7页
考虑数据中心不间断电源(UPS)仅作为供电故障情况下的应急电源,导致正常运行时储能电池大量闲置浪费。为满足数据中心高效、均衡、绿色、安全可靠的供能需求,实现UPS储能最大化利用,该文利用UPS储能功能,联合光伏发电作为数据中心的供... 考虑数据中心不间断电源(UPS)仅作为供电故障情况下的应急电源,导致正常运行时储能电池大量闲置浪费。为满足数据中心高效、均衡、绿色、安全可靠的供能需求,实现UPS储能最大化利用,该文利用UPS储能功能,联合光伏发电作为数据中心的供能主体,兼顾发电侧与需求侧安全、经济性约束,以数据中心供能系统日综合用电成本最小为目标,建立考虑不间断电源储能备用和日常供能的数据中心电—冷联供系统优化运行模型。通过实际算例对模型进行仿真计算,验证所建模型的可行性和有效性。 展开更多
关键词 数据中心 储能系统 服务器集群 电-冷联供
下载PDF
Parametric optimization of power system for a micro-CCHP system 被引量:2
2
作者 李应林 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期297-301,共5页
The universal mathematical model of an engine is established,and an economical zone,in which an engine mainly provides medium output load at medium speed,is presented.Based on the experimental data and the universal m... The universal mathematical model of an engine is established,and an economical zone,in which an engine mainly provides medium output load at medium speed,is presented.Based on the experimental data and the universal model of such an engine above,a mathematical model of a refitted engine is provided.The boundary of the corresponding economical zone is further demarcated,and the optimal operating curve and the operating point of the engine are analyzed.Then,the energy transforming models of the power system are established in the mode of cooling,heating and power(MCHP),the mode of heating and power(MHP)and the mode of electricity powering(MEP).The parameter matching of the power system is optimized according to the transmission ratios of the gear box in the power distribution system.The results show that,in the MCHP,the speed transmission ratio of the engine to the gear box(ies)and the speed transmission ratio of the motor to the gear box(ims)are defined as 2.9 and 1,respectively;in the MHP,when the demand load of the power system is less than the low critical load of the economical zone,the speed transmission ratio of the motor to the engine(ime)is equal to 1,and when the demand load of the power system exceeds the low critical load of the economical zone,ime equals 0.85;in the MEP,the optimal value of ims is defined as 2.5. 展开更多
关键词 combined cooling heating and power distributed energy supply battery bank ENGINE
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
3
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
Data Center as a Key Player of a District Electric Power and Heat Network System: A Comparison in Urban and Suburb Regions
4
作者 Shunsuke Mori Yuuki Hori +1 位作者 Masashi Ohkura Kazuhisa Kamegai 《Computer Technology and Application》 2013年第10期548-555,共8页
A DC (data center) demands air-conditioning power as large as the 1/3-1/2 of total electricity consumption. Thus, energy saving of cooling power of DC yields considerable effect on both economic and environmental vi... A DC (data center) demands air-conditioning power as large as the 1/3-1/2 of total electricity consumption. Thus, energy saving of cooling power of DC yields considerable effect on both economic and environmental views. PV (Photovoltaic) and absorption refrigerator with CGS (cogeneration systems) or gas boiler are possible power saving options. The waste warm air from DC would be utilized for greenhouse heating when DC and greenhouse locate near in the suburbs. In this study, the authors develop an energy network model to assess the potential contribution of DC as a major electric power and chilled air consumer as well as the warm air supplier in a district to the energy efficiency improvement. The evaporation heat of LNG (liquefied natural gas) utilization is also considered as well as PV, CGS. This model is applied to the cases of the urban area in Tokyo which involves athletic center, shops and hospital and the suburbs including greenhouse and then compared. 展开更多
关键词 Data center distributed energy systems urban and suburbs.
下载PDF