Using a gravity anomaly covariance function based on the second-order Ganssian Markov gravity anomaly potential model, the state equation of a gravity anomaly signal is obtained in marine gravimetry. Combined with the...Using a gravity anomaly covariance function based on the second-order Ganssian Markov gravity anomaly potential model, the state equation of a gravity anomaly signal is obtained in marine gravimetry. Combined with the system state equation and the measurement equation, a new method of the cascade Kalman filter is proposed and applied to the correction of gravity anomaly distortion. In the signal processing procedure, an inverse Kalman filter is used to restore the gravity anomaly signal and high frequency noises first. Then an adaptive Kalman filter, which uses the gravity anomaly state equation as the system equation, is set to estimate the actual gravity anomaly data. Emulations and experiments indicate that both the cascade Kalman filter method and the single inverse Kalman filter method are effective in alleviating the distortion of the gravity anomaly signal, but the performance of the cascade Kalman filter method is better than that of the single inverse Kalman filter method.展开更多
VOF (volume of fluid) method has been used to make the numerical simulation of freak wave come true. The comparisons between the numerical results and linear theoretical results corresponding to Eq.(5) have been c...VOF (volume of fluid) method has been used to make the numerical simulation of freak wave come true. The comparisons between the numerical results and linear theoretical results corresponding to Eq.(5) have been carried out to show that the numerical results have a better exhibition of nonlinear characteristics. Wavelet analysis method has been adopted to investigate the time-frequency energy spectrum of simulation freak waves and the results reveal strong nonlinear interaction enables energy to be transferred to high harmonics during the progress of its formation. Varying water depth can enhance the nonlinear interaction, making much more energy be transferred to high harmonics and freak waves with higher asymmetry be generated.展开更多
Objective: To study the value of detecting fetal congenital heart disease (CHD) using the five transverse planes technique of fetal echocardiography. Methods: Nine hundred and eighty-two high-risk pregnancies for feta...Objective: To study the value of detecting fetal congenital heart disease (CHD) using the five transverse planes technique of fetal echocardiography. Methods: Nine hundred and eighty-two high-risk pregnancies for fetal CHD were included in this study, the fetal heart was scanned with the five transverse planes technique of fetal echocardiography described by Yagel, autopsy was conducted when pregnancy was terminated. Blood from fetal heart was collected for fetal chromosome analysis. A close follow-up was given for normal fetal heart pregnancies and neonatal echocardiography was performed to check the accuracy of prenatal diagnosis. Results: (1) Forty-six cases (4.68%) were found to have fetal heart abnormalities in this study, 69.56% of them were diagnosed by single four-chamber view, another 30.43% fetal CHD were found by combining other views; (2) Forty-one parents of prenatal fetuses with CHD chose to terminate pregnancy, thirty-two of them gave consent to conduct autopsy, 93.75% of which yielded unanimous conclusion between prenatal fetal echocardiography and autopsy; (3) Thirty-two of 46 cases underwent fetal chromosome analysis, 8 cases (25%) were found to have abnormal chromosome; (4) Five cases were found to have right ventricle and atrium a little bigger than those on the left side, with the unequal condition being the same after birth, but there were no clinical manifestations and they are healthy for the time being; (5) Nine hundred and thirty-six cases were not found with abnormality in this study, but one case was diagnosed with ventricular septal defect after birth, one case was diagnosed with patent ductus arteriosus, one case had atrial septal defect after birth. Conclusions: (1) The detected CHD rate was 4.68% by screening fetal heart with five transverse planes according to Yagel’s description of high risk population basis for CHD. The coinciding rate of prenatal diagnosis and autopsy was 93.75%; (2) The sensitivity of detecting fetal heart abnormality is 92%, the specificity is 99.6% using the five transverse planes technique of fetal echocardiography; (3) Fetuses with mild or moderate disproportion of right and left side in the heart are potentially healthy babies.展开更多
Applying time-independent non-perturbative formalism to the photo-ionization of hydrogen atom immersed in a strong circularly polarized standing electromagnetic wave, we calculate the shift of energy levels and the di...Applying time-independent non-perturbative formalism to the photo-ionization of hydrogen atom immersed in a strong circularly polarized standing electromagnetic wave, we calculate the shift of energy levels and the distortion of wave functions for the hydrogen atom, the ionization cross section induced by the standing wave, and the angular distribution of photoelectrons and obtain some interesting results.展开更多
This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical...This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector P1 (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage,展开更多
基金Pre-Research Program of General Armament Departmentduring the 11th Five-Year Plan Period(No.51309010201)the National Natural Science Foundation of China(No.60575010)
文摘Using a gravity anomaly covariance function based on the second-order Ganssian Markov gravity anomaly potential model, the state equation of a gravity anomaly signal is obtained in marine gravimetry. Combined with the system state equation and the measurement equation, a new method of the cascade Kalman filter is proposed and applied to the correction of gravity anomaly distortion. In the signal processing procedure, an inverse Kalman filter is used to restore the gravity anomaly signal and high frequency noises first. Then an adaptive Kalman filter, which uses the gravity anomaly state equation as the system equation, is set to estimate the actual gravity anomaly data. Emulations and experiments indicate that both the cascade Kalman filter method and the single inverse Kalman filter method are effective in alleviating the distortion of the gravity anomaly signal, but the performance of the cascade Kalman filter method is better than that of the single inverse Kalman filter method.
文摘VOF (volume of fluid) method has been used to make the numerical simulation of freak wave come true. The comparisons between the numerical results and linear theoretical results corresponding to Eq.(5) have been carried out to show that the numerical results have a better exhibition of nonlinear characteristics. Wavelet analysis method has been adopted to investigate the time-frequency energy spectrum of simulation freak waves and the results reveal strong nonlinear interaction enables energy to be transferred to high harmonics during the progress of its formation. Varying water depth can enhance the nonlinear interaction, making much more energy be transferred to high harmonics and freak waves with higher asymmetry be generated.
基金Project supported by the Start-up Fund for Study-abroad Returnee, Ministry of Education, China
文摘Objective: To study the value of detecting fetal congenital heart disease (CHD) using the five transverse planes technique of fetal echocardiography. Methods: Nine hundred and eighty-two high-risk pregnancies for fetal CHD were included in this study, the fetal heart was scanned with the five transverse planes technique of fetal echocardiography described by Yagel, autopsy was conducted when pregnancy was terminated. Blood from fetal heart was collected for fetal chromosome analysis. A close follow-up was given for normal fetal heart pregnancies and neonatal echocardiography was performed to check the accuracy of prenatal diagnosis. Results: (1) Forty-six cases (4.68%) were found to have fetal heart abnormalities in this study, 69.56% of them were diagnosed by single four-chamber view, another 30.43% fetal CHD were found by combining other views; (2) Forty-one parents of prenatal fetuses with CHD chose to terminate pregnancy, thirty-two of them gave consent to conduct autopsy, 93.75% of which yielded unanimous conclusion between prenatal fetal echocardiography and autopsy; (3) Thirty-two of 46 cases underwent fetal chromosome analysis, 8 cases (25%) were found to have abnormal chromosome; (4) Five cases were found to have right ventricle and atrium a little bigger than those on the left side, with the unequal condition being the same after birth, but there were no clinical manifestations and they are healthy for the time being; (5) Nine hundred and thirty-six cases were not found with abnormality in this study, but one case was diagnosed with ventricular septal defect after birth, one case was diagnosed with patent ductus arteriosus, one case had atrial septal defect after birth. Conclusions: (1) The detected CHD rate was 4.68% by screening fetal heart with five transverse planes according to Yagel’s description of high risk population basis for CHD. The coinciding rate of prenatal diagnosis and autopsy was 93.75%; (2) The sensitivity of detecting fetal heart abnormality is 92%, the specificity is 99.6% using the five transverse planes technique of fetal echocardiography; (3) Fetuses with mild or moderate disproportion of right and left side in the heart are potentially healthy babies.
基金The project supported by National Natural Science Foundation of China under Grant No.10075004 with the calculations supported by the High Performance Computing Center of China (Beijing)
文摘Applying time-independent non-perturbative formalism to the photo-ionization of hydrogen atom immersed in a strong circularly polarized standing electromagnetic wave, we calculate the shift of energy levels and the distortion of wave functions for the hydrogen atom, the ionization cross section induced by the standing wave, and the angular distribution of photoelectrons and obtain some interesting results.
基金Project supported by the National High-Tech R&D Program(863)of China(No.2011AA050204)the National Natural Science Foundation of China(No.51277159)
文摘This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector P1 (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage,