In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The el...In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The electrode prepared using a large applied current density showed an increased internal electroactive area and a significantly improved electrochemical performance.The analytical utility of the prepared dendritic Bi film electrodes for the determination of Pb(Ⅱ)and Cd(Ⅱ)in the range of 5–50 μg·L^(-1)were presented in combination with square wave stripping voltammetry in model solution.Compared with non-porous Bi film electrode,the dendritic Bi film electrode exhibited higher sensitivity and lower detection limit.The prepared Bi film electrode with dendritic structure was also successfully applied to real water sample analysis.展开更多
In this paper, a new thin-layer ion-exchange resin phase analytical method is introduced. It is based on that, the bismuthous cation can associate with iodic anions, so as to formed an anion complex [BiI4-] in a stron...In this paper, a new thin-layer ion-exchange resin phase analytical method is introduced. It is based on that, the bismuthous cation can associate with iodic anions, so as to formed an anion complex [BiI4-] in a strong acidic environments. This anion complex can also exchanges with a weaker anions on the surface active site of anion exchange resin, so that a [R+] [BiI4-] solid phase binary associational system is produced. Owing to the solid system is a great many dispersive particulates, it can be pressed to a thin-layer by press tools of the so called 搕hin-layer resin phase?or 搑esin phase? and using this solid association system spectrophotometry for the determination of trace metals. So it can increase the analytical sensitivity. This association system exhibits maximum absorbance at 460nm, and obeys Beer抯 law over the concentration range 0.01ug/ml^1.20ug/ml of bismuthous(III). It has a molar absorptivity of 7.1×105 [L/mol穋m]. It indicated the resin phase spectrophotometry is a sensitive analytical method for trace bismuthous. It is 18 times higher than routine aqueous spectrophotometry. The relative standard deviations is 1.82% (n=6) for the measurements of 0.5ug/ml Bi(III). The detection limit of Bismuthous(III) is 1.4×10-8mol/L. The method has applied to the analysis Bi(III) in environmental water samples.展开更多
基金Supported by the National Natural Science Foundation of China(51472073,51201058)
文摘In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The electrode prepared using a large applied current density showed an increased internal electroactive area and a significantly improved electrochemical performance.The analytical utility of the prepared dendritic Bi film electrodes for the determination of Pb(Ⅱ)and Cd(Ⅱ)in the range of 5–50 μg·L^(-1)were presented in combination with square wave stripping voltammetry in model solution.Compared with non-porous Bi film electrode,the dendritic Bi film electrode exhibited higher sensitivity and lower detection limit.The prepared Bi film electrode with dendritic structure was also successfully applied to real water sample analysis.
文摘In this paper, a new thin-layer ion-exchange resin phase analytical method is introduced. It is based on that, the bismuthous cation can associate with iodic anions, so as to formed an anion complex [BiI4-] in a strong acidic environments. This anion complex can also exchanges with a weaker anions on the surface active site of anion exchange resin, so that a [R+] [BiI4-] solid phase binary associational system is produced. Owing to the solid system is a great many dispersive particulates, it can be pressed to a thin-layer by press tools of the so called 搕hin-layer resin phase?or 搑esin phase? and using this solid association system spectrophotometry for the determination of trace metals. So it can increase the analytical sensitivity. This association system exhibits maximum absorbance at 460nm, and obeys Beer抯 law over the concentration range 0.01ug/ml^1.20ug/ml of bismuthous(III). It has a molar absorptivity of 7.1×105 [L/mol穋m]. It indicated the resin phase spectrophotometry is a sensitive analytical method for trace bismuthous. It is 18 times higher than routine aqueous spectrophotometry. The relative standard deviations is 1.82% (n=6) for the measurements of 0.5ug/ml Bi(III). The detection limit of Bismuthous(III) is 1.4×10-8mol/L. The method has applied to the analysis Bi(III) in environmental water samples.