在用聚丙烯酸制备超强吸水材料的过程中加入一定量的煅烧煤系高岭土和丙烯酰胺能有效降低材料成本和提高其耐盐性。通过正交实验,找出了制备成本低和耐盐性好的超强吸水复合材料的条件,当煅烧煤系高岭土量为丙烯酸单体质量50%,丙烯酰胺...在用聚丙烯酸制备超强吸水材料的过程中加入一定量的煅烧煤系高岭土和丙烯酰胺能有效降低材料成本和提高其耐盐性。通过正交实验,找出了制备成本低和耐盐性好的超强吸水复合材料的条件,当煅烧煤系高岭土量为丙烯酸单体质量50%,丙烯酰胺加入量为70%,中和度为90%,引发剂和交联剂量分别为0.3%和0.025%时,制得产品吸生理盐水(0.9%N aC l溶液)和吸自来水率分别达到60 g/g和325 g/g,吸水后凝胶强度明显提高。展开更多
Effects of temperatures and salinities on oxygen consumption and ammonia-N excretion rate of clam Meretrix meretrix were studied in laboratory from Oct. 2003 to Jan. 2004. Two schemes were designed in incremented temp...Effects of temperatures and salinities on oxygen consumption and ammonia-N excretion rate of clam Meretrix meretrix were studied in laboratory from Oct. 2003 to Jan. 2004. Two schemes were designed in incremented temperature at 10, 15, 20, 25℃ at 31.5 salinity and in incremented salinity at16.0, 21.0, 26.0, 31.5, 36.0, and 41.0 at 20℃, all for 8-10 days. From 10 to 25℃, both respiration and excretion rate were increased. One-way ANOVA analysis demonstrated significant difference (P〈0.01) in physiological parameters in this temperature range except between 15 and 20℃. The highest Q10 thermal coefficient value (12.27) was acquired between 10 and 15℃, and about 1 between 15 and 20℃, indicating M. meretrix could well acclimate to temperature changes in this range. Salinity also had significant effects on respiration and excretion rate (P〈0.05). The highest values of respiration and excretion rate of M. meretrix were recorded at 16.0 salinity (20℃). These two physiological parameters decreased as salinity increased until reached the minimum Q10 value at 31.5 (20℃), then again, these parameters increased with increasing salinity from 31.5 to 41.0. M. meretrix can catabolize body protein to cope with osmotic pressure stress when environmental salinity is away from its optimal range. No significant difference was observed between 26.0 and 36.0 in salinity (P〉0.05), suggesting that a best metabolic salinity range for this species is between 26.0 and 36.0.展开更多
We studied the effect of pH (pH 5, 6, 7 and 8) on the hatching percentage, survival and reproduction of Artemia strains in Bohai Bay salt ponds. Strains included parthenogenetic Artemia from Bohai Bay (BHB), Artem...We studied the effect of pH (pH 5, 6, 7 and 8) on the hatching percentage, survival and reproduction of Artemia strains in Bohai Bay salt ponds. Strains included parthenogenetic Artemia from Bohai Bay (BHB), Artemiafranciscana from San Francisco Bay, and A. franciscana artificially produced in salt ponds in Vietnam. The latter was included as a potential inoculum for biological management of salt ponds. The hatching percentage of cysts after 24 h and the survival rate of the tested Artemia strains were significantly reduced when exposed to a culture medium at pH 5 for 18 d (P〈0.05). The tolerance of Artemia to 48 h acid exposure varied with developmental stage, increasing in the following order: juvenile, nauplii, pre-adult, with maximum tolerance in adults. All strains of Artemia tested could not reproduce at pH 5. At pH levels from pH 6-8, a higher pH generally resulted in a shorter brood interval and enhanced ovoviviparity. Hence, we suggest that brine acidification has a negative impact on Artemia populations in the Bohai Bay saltworks. Inoculation of Artemia with either local parthenogenetic Artemia or exotic A. franeiscana should be feasible at pH 7-8.展开更多
Ground-coupled heat pumps(GCHP)are commonly used in residential heating system.To mitigate the boreholes temperature dropping with operating time,a new exhaust-air recharging system is developed.The new recharging sys...Ground-coupled heat pumps(GCHP)are commonly used in residential heating system.To mitigate the boreholes temperature dropping with operating time,a new exhaust-air recharging system is developed.The new recharging system can be used in three operational modes.In this paper,a ground-coupled heat recovery ventilation(HRV)model is discussed.A thermal model is set up to find the optimal brine flow rate and heat transfer allocation ratio between exhaust and supply coils for maximum heat recovery efficiency.Contrary to the conventional liquid-loop HRV systems,the brine temperature entering the exhaust coil never goes blow zero(0℃),and hence defrosting is needless in the ground-coupled HRV system.This can make the ground-coupled HRV system over 20% more efficient than a conventional HRV system at low outdoor temperatures.展开更多
文摘在用聚丙烯酸制备超强吸水材料的过程中加入一定量的煅烧煤系高岭土和丙烯酰胺能有效降低材料成本和提高其耐盐性。通过正交实验,找出了制备成本低和耐盐性好的超强吸水复合材料的条件,当煅烧煤系高岭土量为丙烯酸单体质量50%,丙烯酰胺加入量为70%,中和度为90%,引发剂和交联剂量分别为0.3%和0.025%时,制得产品吸生理盐水(0.9%N aC l溶液)和吸自来水率分别达到60 g/g和325 g/g,吸水后凝胶强度明显提高。
基金This work is supported by National High-Tech R & D Program of China,(863 Program) (2002AA603014)
文摘Effects of temperatures and salinities on oxygen consumption and ammonia-N excretion rate of clam Meretrix meretrix were studied in laboratory from Oct. 2003 to Jan. 2004. Two schemes were designed in incremented temperature at 10, 15, 20, 25℃ at 31.5 salinity and in incremented salinity at16.0, 21.0, 26.0, 31.5, 36.0, and 41.0 at 20℃, all for 8-10 days. From 10 to 25℃, both respiration and excretion rate were increased. One-way ANOVA analysis demonstrated significant difference (P〈0.01) in physiological parameters in this temperature range except between 15 and 20℃. The highest Q10 thermal coefficient value (12.27) was acquired between 10 and 15℃, and about 1 between 15 and 20℃, indicating M. meretrix could well acclimate to temperature changes in this range. Salinity also had significant effects on respiration and excretion rate (P〈0.05). The highest values of respiration and excretion rate of M. meretrix were recorded at 16.0 salinity (20℃). These two physiological parameters decreased as salinity increased until reached the minimum Q10 value at 31.5 (20℃), then again, these parameters increased with increasing salinity from 31.5 to 41.0. M. meretrix can catabolize body protein to cope with osmotic pressure stress when environmental salinity is away from its optimal range. No significant difference was observed between 26.0 and 36.0 in salinity (P〉0.05), suggesting that a best metabolic salinity range for this species is between 26.0 and 36.0.
基金Supported by the International Cooperation Research Program of the Ministry of Science&Technology of China(No.2010DFA32300)the Pilot Project for International Cooperation"Aquaculture in Hebei and Shandong Provinces"funded by the Province of East-Flanders,Belgiumthe Nature Science Foundation of Tianjin(No.13JCZDJC28700)
文摘We studied the effect of pH (pH 5, 6, 7 and 8) on the hatching percentage, survival and reproduction of Artemia strains in Bohai Bay salt ponds. Strains included parthenogenetic Artemia from Bohai Bay (BHB), Artemiafranciscana from San Francisco Bay, and A. franciscana artificially produced in salt ponds in Vietnam. The latter was included as a potential inoculum for biological management of salt ponds. The hatching percentage of cysts after 24 h and the survival rate of the tested Artemia strains were significantly reduced when exposed to a culture medium at pH 5 for 18 d (P〈0.05). The tolerance of Artemia to 48 h acid exposure varied with developmental stage, increasing in the following order: juvenile, nauplii, pre-adult, with maximum tolerance in adults. All strains of Artemia tested could not reproduce at pH 5. At pH levels from pH 6-8, a higher pH generally resulted in a shorter brood interval and enhanced ovoviviparity. Hence, we suggest that brine acidification has a negative impact on Artemia populations in the Bohai Bay saltworks. Inoculation of Artemia with either local parthenogenetic Artemia or exotic A. franeiscana should be feasible at pH 7-8.
文摘Ground-coupled heat pumps(GCHP)are commonly used in residential heating system.To mitigate the boreholes temperature dropping with operating time,a new exhaust-air recharging system is developed.The new recharging system can be used in three operational modes.In this paper,a ground-coupled heat recovery ventilation(HRV)model is discussed.A thermal model is set up to find the optimal brine flow rate and heat transfer allocation ratio between exhaust and supply coils for maximum heat recovery efficiency.Contrary to the conventional liquid-loop HRV systems,the brine temperature entering the exhaust coil never goes blow zero(0℃),and hence defrosting is needless in the ground-coupled HRV system.This can make the ground-coupled HRV system over 20% more efficient than a conventional HRV system at low outdoor temperatures.