Introduces a new monitoring method in FMS explicated in some detail by means of the MSF(Monitoring System of FMS)under development by the au- thors.In order to push FMS technology forword,enhance machining flexibility...Introduces a new monitoring method in FMS explicated in some detail by means of the MSF(Monitoring System of FMS)under development by the au- thors.In order to push FMS technology forword,enhance machining flexibility and the flexibility of human operaters and equipment in a FMS,the authors have made some breakthroughs in traditional ways of single item,unit monitoring and self-han- dling,and suggested the idea of integrated inspection and put the MSF into more practicability.The working status of FMS can be monitored on the CRT of a micro- computer of the MSF,system troubles will be shown with icons,by the flash of the system characteristic symbol or by alarming,and so on.This explores a new way for FMS inspection in a wholly integrated manner.展开更多
Pipeline in te grity defect is a considerable portion in all the defects.Therefore, the study o n detection technique is of great concern to the owners of pipelines. A real ti me monitoring system of pipeline defect i...Pipeline in te grity defect is a considerable portion in all the defects.Therefore, the study o n detection technique is of great concern to the owners of pipelines. A real ti me monitoring system of pipeline defect is established. For unexpected accidents of pipeline leakage, several methods of signal processing, including wavelet an alysis are utilized. The leakage can be located accurately in time. This system is applied to many long distance pipelines in China, which has made great contri butions to the economy.展开更多
AIM: To complete a quality audit using recently pub- lished criteria from the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. METHODS: Consecutive colonoscopy reports of patients at averag...AIM: To complete a quality audit using recently pub- lished criteria from the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. METHODS: Consecutive colonoscopy reports of patients at average/high risk screening, or with a prior col6rectal neoplasia (CRN) by endoscopists who perform 11 000 procedures yearly, using a commercial computerized endoscopic report generator. A separate institutional da- tabase providing pathological results. Required documen- tation included patient demographics, history, procedure indications, technical descriptions, colonoscopy findings, interventions, unplanned events, follow-up plans, and pathology results. Reports abstraction employed a stan- dardized glossary with 10% independent data validation. Sample size calculations determined the number of re- ports needed.RESULTS: Two hundreds and fifty patients (63.2± 10.5 years, female: 42.8%, average risk: 38.5%, per- sonal/family history of CRN: 43.3%/20.2%) were scoped in June 2009 by 8 gastroenterologists and 3 surgeons (mean practice: 17.1 ± 8.5 years). Procedural indica- tion and informed consent were always documented. 14% provided a previous colonoscopy date (past polyp removal information in 25%, but insufficient in most to determine surveillance intervals appropriateness). Most procedural indicators were recorded (exam date: 98.4%, medications: 99.2%, difficulty level: 98.8%, prep quality: 99.6%). All reports noted extent of visualization (cecum: 94.4%, with landmarks noted in 78.8% - photodocu- mentation: 67.2%). No procedural times were recorded. One hundred and eleven had polyps (44.4%) with ana- tomic location noted in 99.1%, size in 65.8%, morphol- ogy in 62.2%; removal was by cold biopsy in 25.2% (cold snare: 18%, snare cautery: 31.5%, unrecorded: 20.7%), 84.7% were retrieved. Adenomas were noted in 24.8% (advanced adenomas: 7.6%, cancer: 0.4%) in this population with varying previous colonic investigations. CONCLUSION: This audit reveals lacking reported ite- ms, justifying additional research to optimize quality of reporting.展开更多
This paper proposes a method for transformer fault detection system based on GSM network, through the current transformer, voltage sensor information, the known fault information attribute conditions, and the feedback...This paper proposes a method for transformer fault detection system based on GSM network, through the current transformer, voltage sensor information, the known fault information attribute conditions, and the feedback weighted coefficient through the adaptive feed forward, that can obtain high fault information attributes, thus filtering interference factors and timely get fault information properties. It solves the traditional transformer can only judge general fault and fault real-time alarm by GSM network, the system also can measure the transformer oil temperature and oil temperature alarm in super high temperature, to detect the power transformer operation parameters, and the fault running state (over-current, over-voltage, under-voltage, warning). The actual test system show that, diagnosis ability of fault signal separation ability and small signal identification increases 17%. also meet the requirements of real-time.展开更多
In South Africa, electricity is supplied through thousands-of-kilometers of overhead power cables, which is owned by Eskom the national energy supplier. Currently monitoring of these overhead power cables are done by ...In South Africa, electricity is supplied through thousands-of-kilometers of overhead power cables, which is owned by Eskom the national energy supplier. Currently monitoring of these overhead power cables are done by means of helicopter inspection flights and foot patrols, which are infrequent and expensive. In this paper, the authors present the design of a prototype power line crawler (inspection robot) for the monitoring of these overhead power lines in South Africa. The designed prototype power line crawler is capable of driving on the wire, balancing on the wire and is capable of maneuvering past certain obstacles found on the overhead power cables. The prototype power line crawler is designed to host a monitoring system that monitors the power line as the inspection robot drives on it. Various experimental tests were performed and are presented in this paper, showing the capability of performing these tasks. This prototype inspection robot ensures a platform for future development in this area.展开更多
This paper deals with an integration of directly measured electrical parameters with data acquired by data communication from protections and terminals into an advanced monitoring system. Based on the periodic test, t...This paper deals with an integration of directly measured electrical parameters with data acquired by data communication from protections and terminals into an advanced monitoring system. Based on the periodic test, the authors of this paper present the possibility of an extended evaluation and more accurate analysis of transient and failure events. For periodical testing, as implemented during the commissioning of power plants in the Czech Republic, a monitoring system of electrical equipment has been used, to record the courses of important electrical parameters and thus, proving the proper functioning of complex technological systems in various operation modes. Data from monitoring system were used to prove the successful results of the test or as a base data for further analysis of failures. The monitoring system has proved itself as a very useful device also when recording unexpected failure events, the cause of which was very quickly and accurately detected by the follow-up analysis. Initially, only the voltage and current data from measuring transformers, analogue transducers and contact relays were used as input data for the monitoring system. After the implementation of new digital protection technology and controlling terminals with inner data recorder, the data from digital devices could be also utilized for the monitoring system.展开更多
Under virtualization idea based on large-scale dismantling and sharing, the implementing of network interconnection of calculation components and storage components by loose coupling, which are tightly coupling in tra...Under virtualization idea based on large-scale dismantling and sharing, the implementing of network interconnection of calculation components and storage components by loose coupling, which are tightly coupling in traditional server, achieves computing capacity, storage capacity and service capacity distri- bution according to need in application-level. Under the new server model, the segregation and protection of user space and system space as well as the security monitoring of virtual resources are the important factors of ultimate security guarantee. This article presents a large-scale and expansible distributed invasion detection system of virtual computing environment based on virtual machine. The system supports security monitoring management of global resources and provides uniform view of security attacks under virtual computing environment, thereby protecting the user applications and system security under capacity services domain.展开更多
In optical performance monitoring system,the analog to digital converter is needed to detect the peak of nanosecond pulse and get the signal envelope.A scheme based on a designed anti-aliasing filter and analog to dig...In optical performance monitoring system,the analog to digital converter is needed to detect the peak of nanosecond pulse and get the signal envelope.A scheme based on a designed anti-aliasing filter and analog to digital converter is proposed to broaden the nanosecond pulse and make it easier for the analog to digital converter to catch the peak of the nanosecond pulse.The experimental results demonstrate that,with the proposed scheme,the optical performance system needs less time to get the recovered eye-diagram of high speed optical data signal,and is robust to phase mismatch in the analog to digital converter circuit.展开更多
the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fl...the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fluctuate, that will cause the system to detect the fault isolation ability of confusion and small fault signal is not strong; The article propose a method of power network fault detection for based on GSM, Through the underlying sensing equipment acquisition abnormal information of current, voltage power in the network and GSM networking scheme can filter the interference factors in extraction of fault information from and attribute value. The embedded gateway take STM32 chip as the core to monitoring data processing, to achieve a unified data management and user remote access, realizing method of system software are given, to construct the monitor management information platform. The actual test system show that, identification diagnosis ability of fault signal separation ability and small signal increases 17%, also meet the requirements.展开更多
Optical fiber sensors have attracted considerable attention in health monitoring of aerospace composite structures. This paper briefly reviews our recent advancement mainly in Brillouin-based distributed sensing. Dama...Optical fiber sensors have attracted considerable attention in health monitoring of aerospace composite structures. This paper briefly reviews our recent advancement mainly in Brillouin-based distributed sensing. Damage detection, life cycle monitoring and shape reconstruction systems applicable to large-scale composite structures are presented, and new technical concepts, "smart crack arrester" and "hierarchical sensing system", are described as well, highlighting the great potential of optical fiber sensors for the structural health monitoring (SHM) field.展开更多
文摘Introduces a new monitoring method in FMS explicated in some detail by means of the MSF(Monitoring System of FMS)under development by the au- thors.In order to push FMS technology forword,enhance machining flexibility and the flexibility of human operaters and equipment in a FMS,the authors have made some breakthroughs in traditional ways of single item,unit monitoring and self-han- dling,and suggested the idea of integrated inspection and put the MSF into more practicability.The working status of FMS can be monitored on the CRT of a micro- computer of the MSF,system troubles will be shown with icons,by the flash of the system characteristic symbol or by alarming,and so on.This explores a new way for FMS inspection in a wholly integrated manner.
文摘Pipeline in te grity defect is a considerable portion in all the defects.Therefore, the study o n detection technique is of great concern to the owners of pipelines. A real ti me monitoring system of pipeline defect is established. For unexpected accidents of pipeline leakage, several methods of signal processing, including wavelet an alysis are utilized. The leakage can be located accurately in time. This system is applied to many long distance pipelines in China, which has made great contri butions to the economy.
基金Supported by The Research Scholar (Chercheur National) of the Fonds de la Recherche en Santé du Québec
文摘AIM: To complete a quality audit using recently pub- lished criteria from the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. METHODS: Consecutive colonoscopy reports of patients at average/high risk screening, or with a prior col6rectal neoplasia (CRN) by endoscopists who perform 11 000 procedures yearly, using a commercial computerized endoscopic report generator. A separate institutional da- tabase providing pathological results. Required documen- tation included patient demographics, history, procedure indications, technical descriptions, colonoscopy findings, interventions, unplanned events, follow-up plans, and pathology results. Reports abstraction employed a stan- dardized glossary with 10% independent data validation. Sample size calculations determined the number of re- ports needed.RESULTS: Two hundreds and fifty patients (63.2± 10.5 years, female: 42.8%, average risk: 38.5%, per- sonal/family history of CRN: 43.3%/20.2%) were scoped in June 2009 by 8 gastroenterologists and 3 surgeons (mean practice: 17.1 ± 8.5 years). Procedural indica- tion and informed consent were always documented. 14% provided a previous colonoscopy date (past polyp removal information in 25%, but insufficient in most to determine surveillance intervals appropriateness). Most procedural indicators were recorded (exam date: 98.4%, medications: 99.2%, difficulty level: 98.8%, prep quality: 99.6%). All reports noted extent of visualization (cecum: 94.4%, with landmarks noted in 78.8% - photodocu- mentation: 67.2%). No procedural times were recorded. One hundred and eleven had polyps (44.4%) with ana- tomic location noted in 99.1%, size in 65.8%, morphol- ogy in 62.2%; removal was by cold biopsy in 25.2% (cold snare: 18%, snare cautery: 31.5%, unrecorded: 20.7%), 84.7% were retrieved. Adenomas were noted in 24.8% (advanced adenomas: 7.6%, cancer: 0.4%) in this population with varying previous colonic investigations. CONCLUSION: This audit reveals lacking reported ite- ms, justifying additional research to optimize quality of reporting.
文摘This paper proposes a method for transformer fault detection system based on GSM network, through the current transformer, voltage sensor information, the known fault information attribute conditions, and the feedback weighted coefficient through the adaptive feed forward, that can obtain high fault information attributes, thus filtering interference factors and timely get fault information properties. It solves the traditional transformer can only judge general fault and fault real-time alarm by GSM network, the system also can measure the transformer oil temperature and oil temperature alarm in super high temperature, to detect the power transformer operation parameters, and the fault running state (over-current, over-voltage, under-voltage, warning). The actual test system show that, diagnosis ability of fault signal separation ability and small signal identification increases 17%. also meet the requirements of real-time.
文摘In South Africa, electricity is supplied through thousands-of-kilometers of overhead power cables, which is owned by Eskom the national energy supplier. Currently monitoring of these overhead power cables are done by means of helicopter inspection flights and foot patrols, which are infrequent and expensive. In this paper, the authors present the design of a prototype power line crawler (inspection robot) for the monitoring of these overhead power lines in South Africa. The designed prototype power line crawler is capable of driving on the wire, balancing on the wire and is capable of maneuvering past certain obstacles found on the overhead power cables. The prototype power line crawler is designed to host a monitoring system that monitors the power line as the inspection robot drives on it. Various experimental tests were performed and are presented in this paper, showing the capability of performing these tasks. This prototype inspection robot ensures a platform for future development in this area.
文摘This paper deals with an integration of directly measured electrical parameters with data acquired by data communication from protections and terminals into an advanced monitoring system. Based on the periodic test, the authors of this paper present the possibility of an extended evaluation and more accurate analysis of transient and failure events. For periodical testing, as implemented during the commissioning of power plants in the Czech Republic, a monitoring system of electrical equipment has been used, to record the courses of important electrical parameters and thus, proving the proper functioning of complex technological systems in various operation modes. Data from monitoring system were used to prove the successful results of the test or as a base data for further analysis of failures. The monitoring system has proved itself as a very useful device also when recording unexpected failure events, the cause of which was very quickly and accurately detected by the follow-up analysis. Initially, only the voltage and current data from measuring transformers, analogue transducers and contact relays were used as input data for the monitoring system. After the implementation of new digital protection technology and controlling terminals with inner data recorder, the data from digital devices could be also utilized for the monitoring system.
基金Supported by the High Technology Research and Development Programme of China (No. 2003AA1Z2070 ) and the National Natural Science Foundation of China (No. 90412013).
文摘Under virtualization idea based on large-scale dismantling and sharing, the implementing of network interconnection of calculation components and storage components by loose coupling, which are tightly coupling in traditional server, achieves computing capacity, storage capacity and service capacity distri- bution according to need in application-level. Under the new server model, the segregation and protection of user space and system space as well as the security monitoring of virtual resources are the important factors of ultimate security guarantee. This article presents a large-scale and expansible distributed invasion detection system of virtual computing environment based on virtual machine. The system supports security monitoring management of global resources and provides uniform view of security attacks under virtual computing environment, thereby protecting the user applications and system security under capacity services domain.
基金supported by National 863 Program of China(2013AA013401),P.R.ChinaNational Natural Science Foundation of China under Grant No.61177067,No.61027007,and No.61331010
文摘In optical performance monitoring system,the analog to digital converter is needed to detect the peak of nanosecond pulse and get the signal envelope.A scheme based on a designed anti-aliasing filter and analog to digital converter is proposed to broaden the nanosecond pulse and make it easier for the analog to digital converter to catch the peak of the nanosecond pulse.The experimental results demonstrate that,with the proposed scheme,the optical performance system needs less time to get the recovered eye-diagram of high speed optical data signal,and is robust to phase mismatch in the analog to digital converter circuit.
文摘the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fluctuate, that will cause the system to detect the fault isolation ability of confusion and small fault signal is not strong; The article propose a method of power network fault detection for based on GSM, Through the underlying sensing equipment acquisition abnormal information of current, voltage power in the network and GSM networking scheme can filter the interference factors in extraction of fault information from and attribute value. The embedded gateway take STM32 chip as the core to monitoring data processing, to achieve a unified data management and user remote access, realizing method of system software are given, to construct the monitor management information platform. The actual test system show that, identification diagnosis ability of fault signal separation ability and small signal increases 17%, also meet the requirements.
文摘Optical fiber sensors have attracted considerable attention in health monitoring of aerospace composite structures. This paper briefly reviews our recent advancement mainly in Brillouin-based distributed sensing. Damage detection, life cycle monitoring and shape reconstruction systems applicable to large-scale composite structures are presented, and new technical concepts, "smart crack arrester" and "hierarchical sensing system", are described as well, highlighting the great potential of optical fiber sensors for the structural health monitoring (SHM) field.