便携式γ谱仪主要用于主冷却剂水样中典型核素的现场辅助识别及其活度浓度的测量分析。为确定典型核素特征峰净面积和水样中该核素活度浓度的关系,必须进行源峰效率刻度。本文通过测量133Ba、137 Cs、60 Co 3种核素的混合溶液得到效率...便携式γ谱仪主要用于主冷却剂水样中典型核素的现场辅助识别及其活度浓度的测量分析。为确定典型核素特征峰净面积和水样中该核素活度浓度的关系,必须进行源峰效率刻度。本文通过测量133Ba、137 Cs、60 Co 3种核素的混合溶液得到效率刻度曲线,然后对不同活度浓度的137 Cs标准溶液、131I标准模拟溶液进行测量。结果表明,谱仪均能正确识别137 Cs、131I核素,活度浓度测量的相对误差均<10%,初步满足元件破损监测精度和灵敏度的需求。展开更多
Based on the physical meaning of sensitivity,a new finite element(FE) model updating method was proposed. In this method,a three-dimensional FE model of the Nanjing Yangtze River Bridge(NYRB) with ANSYS program was es...Based on the physical meaning of sensitivity,a new finite element(FE) model updating method was proposed. In this method,a three-dimensional FE model of the Nanjing Yangtze River Bridge(NYRB) with ANSYS program was established and updated by modifying some design parameters. To further validate the updated FE model,the analytical stress-time histories responses of main members induced by a moving train were compared with the measured ones. The results show that the relative error of maximum stress is 2.49% and the minimum relative coefficient of analytical stress-time histories responses is 0.793. The updated model has a good agreement between the calculated data and the tested data,and provides a current baseline FE model for long-term health monitoring and condition assessment of the NYRB. At the same time,the model is validated by stress-time histories responses to be feasible and practical for railway steel bridge model updating.展开更多
The piezoelectric effect is used in sensing applications such as in force and displacement sensors.However,the brittleness and low performance of piezoceramic lead zirconate titanate(PZT) often impede its applicabilit...The piezoelectric effect is used in sensing applications such as in force and displacement sensors.However,the brittleness and low performance of piezoceramic lead zirconate titanate(PZT) often impede its applicability in civil structures which are subjected to large loads.The concept of a piezocomposite electricity generating element(PCGE) has been proposed for improving the electricity generation performance and overcoming the brittleness of piezoceramic wafers.The post-curing residual stress in the PZT layer constitutes a main reason for the PCGE's enhanced performance,and the outer epoxy-based composites protect the brittle PZT layer.A d33-mode PCGE designed for bridge monitoring application was inserted in a bridge bearing to provide a permanent and simple weigh-in-motion system.The designed PCGEs were tested through a series of tests including fatigue and dynamic tests to verify their applicability for monitoring purposes in a bridge structure.A simple beam example was presented to show the applicability of the proposed bridge bearing equipped with the PCGE for adequately measuring the traffic loads.展开更多
基金Project(2001G025) supported by the Foundation of the Science and Technology Section of Ministry of Railway of ChinaProject(2006FJ4233) supported by Hunan Postdoctoral Scientific Program of ChinaProject(2006) supported by the Postdoctoral Foundation of Central South University,China
文摘Based on the physical meaning of sensitivity,a new finite element(FE) model updating method was proposed. In this method,a three-dimensional FE model of the Nanjing Yangtze River Bridge(NYRB) with ANSYS program was established and updated by modifying some design parameters. To further validate the updated FE model,the analytical stress-time histories responses of main members induced by a moving train were compared with the measured ones. The results show that the relative error of maximum stress is 2.49% and the minimum relative coefficient of analytical stress-time histories responses is 0.793. The updated model has a good agreement between the calculated data and the tested data,and provides a current baseline FE model for long-term health monitoring and condition assessment of the NYRB. At the same time,the model is validated by stress-time histories responses to be feasible and practical for railway steel bridge model updating.
基金Project supported by Konkuk University,Korea,in 2014
文摘The piezoelectric effect is used in sensing applications such as in force and displacement sensors.However,the brittleness and low performance of piezoceramic lead zirconate titanate(PZT) often impede its applicability in civil structures which are subjected to large loads.The concept of a piezocomposite electricity generating element(PCGE) has been proposed for improving the electricity generation performance and overcoming the brittleness of piezoceramic wafers.The post-curing residual stress in the PZT layer constitutes a main reason for the PCGE's enhanced performance,and the outer epoxy-based composites protect the brittle PZT layer.A d33-mode PCGE designed for bridge monitoring application was inserted in a bridge bearing to provide a permanent and simple weigh-in-motion system.The designed PCGEs were tested through a series of tests including fatigue and dynamic tests to verify their applicability for monitoring purposes in a bridge structure.A simple beam example was presented to show the applicability of the proposed bridge bearing equipped with the PCGE for adequately measuring the traffic loads.