When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is...When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.展开更多
This paper discusses the characteristics of DC transmission common system ground electrode type and shared ground electrode, established the mathematical model of two circuit DC systems share ground electrode, analyze...This paper discusses the characteristics of DC transmission common system ground electrode type and shared ground electrode, established the mathematical model of two circuit DC systems share ground electrode, analyze effects of the shared loop ground DC transmission system electrode on the operation of HVDC system size under different operation modes, and compare with the independent ground electrode, ground electrode impact on environment under different operation mode, and the paper finally puts forward some solving measures for the influence of the shared ground electrode on the environment and public ground electrode effects on DC system operation problems.展开更多
文摘When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.
文摘This paper discusses the characteristics of DC transmission common system ground electrode type and shared ground electrode, established the mathematical model of two circuit DC systems share ground electrode, analyze effects of the shared loop ground DC transmission system electrode on the operation of HVDC system size under different operation modes, and compare with the independent ground electrode, ground electrode impact on environment under different operation mode, and the paper finally puts forward some solving measures for the influence of the shared ground electrode on the environment and public ground electrode effects on DC system operation problems.