直流分流器电阻测量结果的不确定度评定
1
作者 庞建龙 刘琼芳 杨雨梅 《电子产品可靠性与环境试验》 2024年第4期89-96,共8页
测量不确定度是直流分流器校准的一项重要内容。但实际校准过程中经常会因为测量模型不准确、不确定度传播率计算错误、不确定度分量考虑不全面和不确定度分量重复计算等原因而导致无法得到较为准确、客观的不确定度。分别介绍了使用直... 测量不确定度是直流分流器校准的一项重要内容。但实际校准过程中经常会因为测量模型不准确、不确定度传播率计算错误、不确定度分量考虑不全面和不确定度分量重复计算等原因而导致无法得到较为准确、客观的不确定度。分别介绍了使用直流标准源法、标准分流器法、直流电流比较器法和直流电阻电桥法校准直流分流器电阻参数时的不确定度评定过程,并给出了各校准方法下的测量模型、不确定度传播率、不确定度来源,以及各不确定度分量、合成标准不确定度和扩展不确定度的计算方法,以期对相关人员有所帮助。 展开更多
关键词 直流分流器 校准 不确定度 直流标准源法 标准分流器法 直流电流比较器 直流电阻电桥法
下载PDF
Automated dual source systems for measurement of DC resistance standards
2
作者 Rasha S M Ali M Helmy A Raouf 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第2期109-115,共7页
A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratori... A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratories without cryogenic current comparators(CCC)or direct current comparators(DCC)bridges.Behavior of this bridge is evaluated by comparing its measured values with the unknown resistor values obtained by another method.The accuracy of the introduced bridge is in the level of 10-5 for the 1 mΩresistor,and in the level of 10-4 for the 10 mΩ,100 mΩand 1Ωresistors.Moreover,a dual voltage sources system for the measurement of DC standard resistors from 1 kΩto 100 MΩis also presented.In this system,a modification is made on the modified Wheatstone bridge to evaluate its performance by adding another digital multimeter to measure the ratio between the unknown and the standard resistors simultaneously.This bridge is verified by comparing the measured values of 10 kΩresistor obtained by the two methods with its actual value.The bridge accuracy is in the level of 10-6 except for the 1 kΩresistor,and the bridge asymmetry is also evaluated.It is found the asymmetry is in the level of 10-6 for the resistors from 10 kΩto 100 MΩand in the level of 10-5 for 1 kΩresistors.The introduced bridges operations are controlled by LabVIEW programs designed specially for this purpose,and the expanded uncertainty is also evaluated for all measurement results. 展开更多
关键词 direct current comparators voltage null detector modified Wheatstone bridge ratio technique resistance measurements UNCERTAINTY
下载PDF