For the rapid calibration of multi-line structured light system,a method based on Plücker line was proposed.Most of the conventional line-structured light calibration methods extract the feature points and transf...For the rapid calibration of multi-line structured light system,a method based on Plücker line was proposed.Most of the conventional line-structured light calibration methods extract the feature points and transform the coordinates of points to obtain the plane equation.However,a large number of points lead to complicated operation which is not suitable for the application scenarios of multi-line structured light.To solve this issue,a new calibration method was proposed that applied the form of Plücker matrix throughout the whole calibration process,instead of using the point characteristics directly.The advantage of this method is that the light plane equation can be obtained quickly and accurately in the camera coordinate frame.Correspondingly a planar target particularly for calibrating multi-line structured light was also designed.The regular lines were transformed into Plücker lines by extending the two-dimensional image plane and defining a new image space.To transform the coordinate frame of Plücker lines,the perspective projection mathematical model was re-expressed based on the Plücker matrix.According to the properties of the line and plane in the Plücker space,a linear matrix equation was efficiently constructed by combining the Plücker matrices of several coplanar lines so that the line-structured light plane equation could be furtherly solved.The experiments performed validate the proposed method and demonstrate the significant improvement in the calibration accuracy,when the test distance is 1.8 m,the root mean square(RMS)error of the three-dimensional point is within 0.08 mm.展开更多
基金National Natural Science Foundation of China(No.51575388)。
文摘For the rapid calibration of multi-line structured light system,a method based on Plücker line was proposed.Most of the conventional line-structured light calibration methods extract the feature points and transform the coordinates of points to obtain the plane equation.However,a large number of points lead to complicated operation which is not suitable for the application scenarios of multi-line structured light.To solve this issue,a new calibration method was proposed that applied the form of Plücker matrix throughout the whole calibration process,instead of using the point characteristics directly.The advantage of this method is that the light plane equation can be obtained quickly and accurately in the camera coordinate frame.Correspondingly a planar target particularly for calibrating multi-line structured light was also designed.The regular lines were transformed into Plücker lines by extending the two-dimensional image plane and defining a new image space.To transform the coordinate frame of Plücker lines,the perspective projection mathematical model was re-expressed based on the Plücker matrix.According to the properties of the line and plane in the Plücker space,a linear matrix equation was efficiently constructed by combining the Plücker matrices of several coplanar lines so that the line-structured light plane equation could be furtherly solved.The experiments performed validate the proposed method and demonstrate the significant improvement in the calibration accuracy,when the test distance is 1.8 m,the root mean square(RMS)error of the three-dimensional point is within 0.08 mm.