According to the fact that the surface of liquid with low viscosity coefficient is a good reflection plane for a broadband light beam, liquid-level measurement in micrometer resolution is designed based on a fiber-opt...According to the fact that the surface of liquid with low viscosity coefficient is a good reflection plane for a broadband light beam, liquid-level measurement in micrometer resolution is designed based on a fiber-optic low coherence interferometer in Michelson configuration. The wave front of the reflected light beam is well enough to form an interferogram with a beam reflected from an optic mirror mounted on a stepping scanning-motor. The central peak of the interferogram is read as a measure of the liquid level. Experimental results show that this noncontact method can reach a resolution of ±1.25 μm in the measurement range of 86 mm.展开更多
We give an analytical result for the quantum Fisher information of entangled coherent states in a lossy Mach-Zehnder interferometer recently proposed by Joo et al., [Phys. Rev. Lett. 107 (2011) 083601]. For small lo...We give an analytical result for the quantum Fisher information of entangled coherent states in a lossy Mach-Zehnder interferometer recently proposed by Joo et al., [Phys. Rev. Lett. 107 (2011) 083601]. For small loss of photons, we find that the entangled coherent state can surpass the Heisenberg limit. Phrthermore, the formalism developed here is applicable to the study of phase sensitivity of multipartite entangled coherent states.展开更多
基金Dalian Science and Technology Foundation and National Science Foundation(30470416)
文摘According to the fact that the surface of liquid with low viscosity coefficient is a good reflection plane for a broadband light beam, liquid-level measurement in micrometer resolution is designed based on a fiber-optic low coherence interferometer in Michelson configuration. The wave front of the reflected light beam is well enough to form an interferogram with a beam reflected from an optic mirror mounted on a stepping scanning-motor. The central peak of the interferogram is read as a measure of the liquid level. Experimental results show that this noncontact method can reach a resolution of ±1.25 μm in the measurement range of 86 mm.
基金Supported by National Fundamental Research Program of China under Grant No.2012CB921602National Natural Science Foun-dation of China under Grant Nos.11025527 and 10935010
文摘We give an analytical result for the quantum Fisher information of entangled coherent states in a lossy Mach-Zehnder interferometer recently proposed by Joo et al., [Phys. Rev. Lett. 107 (2011) 083601]. For small loss of photons, we find that the entangled coherent state can surpass the Heisenberg limit. Phrthermore, the formalism developed here is applicable to the study of phase sensitivity of multipartite entangled coherent states.