Purpose: To document the magnitude of any learning effect for short-wave length automated perimetry (SWAP) in patients with either ocular hypertension (OHT) or open-angle glaucoma (OAG) who are experienced in standard...Purpose: To document the magnitude of any learning effect for short-wave length automated perimetry (SWAP) in patients with either ocular hypertension (OHT) or open-angle glaucoma (OAG) who are experienced in standard automated perimetry (SAP). Design: Experimental study. Participants: Thirty-five patients (22 with OHT and 13 with OAG) who had previously undergone at least 3 threshold SAP visual field examinations with the Humphrey Field Analyzer (HFA; Carl Zeiss Meditech Inc.,Dublin,CA),and 9 patients with OHT who had not previously undertaken any form of perimetry. Methods: Each patient attended for SWAP on 5 occasions,each separated by 1 week. At each visit,both eyes were examined using Program 24-2 of the HFA; the right eye was always examined before the left eye. Main Outcome Measures: (1) Change over the 5 examinations,in each eye,of the visual field indices Mean Deviation (MD),Short-term Fluctuation (SF),Pattern Standard Deviation (PSD),and Corrected Pattern Standard Deviation. (2) Change in each eye between Visits 1 and 5 in proportionate Mean Sensitivity (pMS) for the central annulus of stimulus locations compared with that for the peripheral annulus thereby determining the influence of stimulus eccentricity on any alteration in sensitivity. (3) Change between Visits 1 and 5 in the number and magnitude of the Pattern Deviation (PD) probability levels associated with any alteration in sensitivity. Results: The MD,SF,and PSD each improved over the 5 examinations (each at P< 0.001). The improvement in pMS between Visits 1 and 5 was greater for the peripheral annulus than for the central annulus by approximately two fold for the patients with OAG. Considerable variation was present between patients,within and between groups,in the number of locations exhibiting an improving sensitivity between Visits 1 and 5 by 1 or more PD probability levels. Conclusions: Care should be taken to ensure that,during the initial examinations,apparent field loss with SWAP in patients exhibiting a normal field by SAP is not the result of inexperience in SWAP. Apparently deeper or wider field loss in the initial examinations with SWAP compared with that exhibited by SAP in OAG also may arise from inexperience in SWAP.展开更多
目的探讨短波自动视野检查(SWAP)在早期原发性开角型青光眼(POAG)中的应用价值。方法应用Humphrey II 750i电脑自动视野分析仪对正常组、早期POAG患者分别进行白白视野(WWP)、SWAP检查,并对各组测得的平均偏差(MD)、图形标准偏差(PSD)...目的探讨短波自动视野检查(SWAP)在早期原发性开角型青光眼(POAG)中的应用价值。方法应用Humphrey II 750i电脑自动视野分析仪对正常组、早期POAG患者分别进行白白视野(WWP)、SWAP检查,并对各组测得的平均偏差(MD)、图形标准偏差(PSD)、缺损点数(选择模式偏差概率图中P<0.05的异常点)进行比较和分析。结果早期POAG患者的SWAP检测的MD、PSD较WWP检测的数值大,缺损点数多,二者比较差异有统计学意义(P<0.05)。早期POAG患者42只眼中SWAP检测阳性者38只眼,阳性率为90.48%;WWP检测阳性者28只眼,阳性率为66.67%。结论在POAG的早期诊断中SWAP较WWP更敏感,检出的阳性率更高,SWAP较WWP检出的视野缺损更深范围更大,甚至能够发现一些WWP所不能检测出的已受损的检测位点。展开更多
Purpose:To assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation.Methods:Twenty-five eyes(25 patients)with primary openangle glaucoma were evaluated,prospective...Purpose:To assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation.Methods:Twenty-five eyes(25 patients)with primary openangle glaucoma were evaluated,prospectively.Data were collected on vision acuity,intraocular pressure,standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry(GDx)and confocal scanning laser ophthalmoscopy(HRT II)before and 3-6 months after surgery.Results:Mean(± SD)pre-and postoperative visual acuities(logMAR)were 0.28(± 0.18)and 0.30(± 0.17),respectively(P=0.346).In a mean time of 4.5(± 1.1)months after surgery,the mean preoperative intraocular pressure of 20.7(± 5.4)mmHg decreased to 11.04(± 2.52)mmHg(P < 0.001).The results of the standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy diagnostic methods revealed no significant difference(P > 0.162)between pre and postoperative values and no significant correlation(P > 0.296)between intraocular pressure reduction and value changes.Conclusion:No significant change on any test variable was detected after glaucoma filtration surgery.Trabeculectomy does not appear to influence standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy(HRT II)results after a 4.5-month period of surgery in early to moderate glaucoma.展开更多
Purpose: To correlate structural parameters of the optic nerve head and global indices of short-wavelength automated perimetry (SWAP) in ocular hypertensives. Methods: The study included 195 eyes with ocular hypertens...Purpose: To correlate structural parameters of the optic nerve head and global indices of short-wavelength automated perimetry (SWAP) in ocular hypertensives. Methods: The study included 195 eyes with ocular hypertension (IOP>21 mmHg, normal conventional automated perimetry). Short-wavelength automated perimetry was performed (full-threshold, 24-2). The optic展开更多
Purpose: To evaluate the topographic concordance between sensibility values of short wave automated perimetry (SWAP) and frequency doubling technology (FDT) in ocular hypertension. Methods: 22 eyes of 22 patients diag...Purpose: To evaluate the topographic concordance between sensibility values of short wave automated perimetry (SWAP) and frequency doubling technology (FDT) in ocular hypertension. Methods: 22 eyes of 22 patients diagnosed of ocular hypertension underwent SWAP (24-2 test, Humphrey analyser) and FDT (C-20 threshold test). According the 17 points examined展开更多
0203251 老年人群中发现眼病试验的敏感性和特异性/Ivers R Q∥J Am Aead Oph-thalmol.-2001,108(5).-968~975北大图0203252 短波长自动视野检查的最适宜标准/Polo V∥J Am Acad Ophthalmol.-2000,108(2).-285~289
文摘Purpose: To document the magnitude of any learning effect for short-wave length automated perimetry (SWAP) in patients with either ocular hypertension (OHT) or open-angle glaucoma (OAG) who are experienced in standard automated perimetry (SAP). Design: Experimental study. Participants: Thirty-five patients (22 with OHT and 13 with OAG) who had previously undergone at least 3 threshold SAP visual field examinations with the Humphrey Field Analyzer (HFA; Carl Zeiss Meditech Inc.,Dublin,CA),and 9 patients with OHT who had not previously undertaken any form of perimetry. Methods: Each patient attended for SWAP on 5 occasions,each separated by 1 week. At each visit,both eyes were examined using Program 24-2 of the HFA; the right eye was always examined before the left eye. Main Outcome Measures: (1) Change over the 5 examinations,in each eye,of the visual field indices Mean Deviation (MD),Short-term Fluctuation (SF),Pattern Standard Deviation (PSD),and Corrected Pattern Standard Deviation. (2) Change in each eye between Visits 1 and 5 in proportionate Mean Sensitivity (pMS) for the central annulus of stimulus locations compared with that for the peripheral annulus thereby determining the influence of stimulus eccentricity on any alteration in sensitivity. (3) Change between Visits 1 and 5 in the number and magnitude of the Pattern Deviation (PD) probability levels associated with any alteration in sensitivity. Results: The MD,SF,and PSD each improved over the 5 examinations (each at P< 0.001). The improvement in pMS between Visits 1 and 5 was greater for the peripheral annulus than for the central annulus by approximately two fold for the patients with OAG. Considerable variation was present between patients,within and between groups,in the number of locations exhibiting an improving sensitivity between Visits 1 and 5 by 1 or more PD probability levels. Conclusions: Care should be taken to ensure that,during the initial examinations,apparent field loss with SWAP in patients exhibiting a normal field by SAP is not the result of inexperience in SWAP. Apparently deeper or wider field loss in the initial examinations with SWAP compared with that exhibited by SAP in OAG also may arise from inexperience in SWAP.
文摘目的探讨短波自动视野检查(SWAP)在早期原发性开角型青光眼(POAG)中的应用价值。方法应用Humphrey II 750i电脑自动视野分析仪对正常组、早期POAG患者分别进行白白视野(WWP)、SWAP检查,并对各组测得的平均偏差(MD)、图形标准偏差(PSD)、缺损点数(选择模式偏差概率图中P<0.05的异常点)进行比较和分析。结果早期POAG患者的SWAP检测的MD、PSD较WWP检测的数值大,缺损点数多,二者比较差异有统计学意义(P<0.05)。早期POAG患者42只眼中SWAP检测阳性者38只眼,阳性率为90.48%;WWP检测阳性者28只眼,阳性率为66.67%。结论在POAG的早期诊断中SWAP较WWP更敏感,检出的阳性率更高,SWAP较WWP检出的视野缺损更深范围更大,甚至能够发现一些WWP所不能检测出的已受损的检测位点。
文摘Purpose:To assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation.Methods:Twenty-five eyes(25 patients)with primary openangle glaucoma were evaluated,prospectively.Data were collected on vision acuity,intraocular pressure,standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry(GDx)and confocal scanning laser ophthalmoscopy(HRT II)before and 3-6 months after surgery.Results:Mean(± SD)pre-and postoperative visual acuities(logMAR)were 0.28(± 0.18)and 0.30(± 0.17),respectively(P=0.346).In a mean time of 4.5(± 1.1)months after surgery,the mean preoperative intraocular pressure of 20.7(± 5.4)mmHg decreased to 11.04(± 2.52)mmHg(P < 0.001).The results of the standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy diagnostic methods revealed no significant difference(P > 0.162)between pre and postoperative values and no significant correlation(P > 0.296)between intraocular pressure reduction and value changes.Conclusion:No significant change on any test variable was detected after glaucoma filtration surgery.Trabeculectomy does not appear to influence standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy(HRT II)results after a 4.5-month period of surgery in early to moderate glaucoma.
文摘Purpose: To correlate structural parameters of the optic nerve head and global indices of short-wavelength automated perimetry (SWAP) in ocular hypertensives. Methods: The study included 195 eyes with ocular hypertension (IOP>21 mmHg, normal conventional automated perimetry). Short-wavelength automated perimetry was performed (full-threshold, 24-2). The optic
文摘Purpose: To evaluate the topographic concordance between sensibility values of short wave automated perimetry (SWAP) and frequency doubling technology (FDT) in ocular hypertension. Methods: 22 eyes of 22 patients diagnosed of ocular hypertension underwent SWAP (24-2 test, Humphrey analyser) and FDT (C-20 threshold test). According the 17 points examined
文摘0203251 老年人群中发现眼病试验的敏感性和特异性/Ivers R Q∥J Am Aead Oph-thalmol.-2001,108(5).-968~975北大图0203252 短波长自动视野检查的最适宜标准/Polo V∥J Am Acad Ophthalmol.-2000,108(2).-285~289