This paper mainly deals with the present situation, characteristics, and countermeasures of cooling in deep mines.Given existing problems in coal mines, a HEMS cooling technology is proposed and has been successfully ...This paper mainly deals with the present situation, characteristics, and countermeasures of cooling in deep mines.Given existing problems in coal mines, a HEMS cooling technology is proposed and has been successfully applied in some mines.Because of long-term exploitation, shallow buried coal seams have become exhausted and most coal mines have had to exploit deep buried coal seams.With the increase in mining depth, the temperature of the surrounding rock also increases, resulting in ever increasing risks of heat hazard during mining operations.At present, coal mines in China can be divided into three groups, i.e., normal temperature mines, middle-to-high temperature mines and high temperature mines, based on our investigation into high temperature coal mines in four provinces and on in-situ studies of several typical mines.The principle of HEMS is to extract cold energy from mine water inrush.Based on the characteristics of strata temperature field and on differences in the amounts of mine water inrush in the Xuzhou mining area, we proposed three models for controlling heat hazard in deep mines:1) the Jiahe model with a moderate source of cold energy;2) the Sanhejian model with a shortage of source of cold energy and a geothermal anomaly and 3) the Zhangshuanglou model with plenty of source of cold energy.The cooling process of HEMS applied in deep coal mine are as follows:1) extract cold energy from mine water inrush to cool working faces;2) use the heat extracted by HEMS to supply heat to buildings and bath water to replace the use of a boiler, a useful energy saving and environmental protection measure.HEMS has been applied in the Jiahe and Sanhejian coal mines in Xuzhou, which enabled the temperature and humidity at the working faces to be well controlled.展开更多
Mine drainage could be filtered and purified through goaf. This innovative technique shows merits, such as high treatment efficiency, remarkable economic benefit and extensive wastewater recycle use. However, it was d...Mine drainage could be filtered and purified through goaf. This innovative technique shows merits, such as high treatment efficiency, remarkable economic benefit and extensive wastewater recycle use. However, it was detected that capacities of purifying mine drainage for goaf were decreased after a period of application. As a result, the effluent could not meet the standard of recycle water. To solve the problem, coagulant was considered to add into mine drainage reducing its high turbid degrees to certain level. After the preliminary flocculation treatment, mine drainage was piped into goaf to purify. In this way, the load of goaf was eased up. Its usage time was also prolonged. Therefore, this paper carried out the coagulation-flocculation jar test for mine drainage to discuss the flocculation parameters. By the experiment, 10 % iron trichloride is selected from four inorganic coagulants as the optimum coagulant. The optimum dose, PH value and sedirs6-7 and 25 min. Velocity mentation time are respectively 2 mL per 800 mL Wastewater gradient G during the process of mixing and reaction is 696 .And the value of GT is 6.264 × 10^5. The values of G and GT will supply the basis for the design of flocculation pool in the project. The flocculation parameters will be significant for the reference of practice.展开更多
基金Project 2006CB202200 supported by the National Basic Research Program of Chinathe National Major Project of Ministry of Education (304005)the Program for Changjiang Scholars and Innovative Research Team in University of China (NoIRT0656)
文摘This paper mainly deals with the present situation, characteristics, and countermeasures of cooling in deep mines.Given existing problems in coal mines, a HEMS cooling technology is proposed and has been successfully applied in some mines.Because of long-term exploitation, shallow buried coal seams have become exhausted and most coal mines have had to exploit deep buried coal seams.With the increase in mining depth, the temperature of the surrounding rock also increases, resulting in ever increasing risks of heat hazard during mining operations.At present, coal mines in China can be divided into three groups, i.e., normal temperature mines, middle-to-high temperature mines and high temperature mines, based on our investigation into high temperature coal mines in four provinces and on in-situ studies of several typical mines.The principle of HEMS is to extract cold energy from mine water inrush.Based on the characteristics of strata temperature field and on differences in the amounts of mine water inrush in the Xuzhou mining area, we proposed three models for controlling heat hazard in deep mines:1) the Jiahe model with a moderate source of cold energy;2) the Sanhejian model with a shortage of source of cold energy and a geothermal anomaly and 3) the Zhangshuanglou model with plenty of source of cold energy.The cooling process of HEMS applied in deep coal mine are as follows:1) extract cold energy from mine water inrush to cool working faces;2) use the heat extracted by HEMS to supply heat to buildings and bath water to replace the use of a boiler, a useful energy saving and environmental protection measure.HEMS has been applied in the Jiahe and Sanhejian coal mines in Xuzhou, which enabled the temperature and humidity at the working faces to be well controlled.
文摘Mine drainage could be filtered and purified through goaf. This innovative technique shows merits, such as high treatment efficiency, remarkable economic benefit and extensive wastewater recycle use. However, it was detected that capacities of purifying mine drainage for goaf were decreased after a period of application. As a result, the effluent could not meet the standard of recycle water. To solve the problem, coagulant was considered to add into mine drainage reducing its high turbid degrees to certain level. After the preliminary flocculation treatment, mine drainage was piped into goaf to purify. In this way, the load of goaf was eased up. Its usage time was also prolonged. Therefore, this paper carried out the coagulation-flocculation jar test for mine drainage to discuss the flocculation parameters. By the experiment, 10 % iron trichloride is selected from four inorganic coagulants as the optimum coagulant. The optimum dose, PH value and sedirs6-7 and 25 min. Velocity mentation time are respectively 2 mL per 800 mL Wastewater gradient G during the process of mixing and reaction is 696 .And the value of GT is 6.264 × 10^5. The values of G and GT will supply the basis for the design of flocculation pool in the project. The flocculation parameters will be significant for the reference of practice.