Extraction of a coal seam which lies not far below a heating goafcan be a major safety challenge. A force auxiliary ventilation system was adopted as a control method in successful extraction and recovery of the panel...Extraction of a coal seam which lies not far below a heating goafcan be a major safety challenge. A force auxiliary ventilation system was adopted as a control method in successful extraction and recovery of the panel 30110 of the #3-1 coal seam, which is about 30-40 rn below the heating goaf of the #2-2 seam at Longhua underground coal mine, Shanxi Province, China. Booster fans and ventilation control devices such as doors and regulators were used in the system. The results show that, provided that a force auxiliary ventilation system is properly designed to achieve a pressure balance between a panel and its overlying goat', the system can be used to extract a coal seam overlain by a heating goal. This paper describes the design, installation and performance of the ventilation system during the extraction and recovery phases of the oanel 30110.展开更多
Mine drainage could be filtered and purified through goaf. This innovative technique shows merits, such as high treatment efficiency, remarkable economic benefit and extensive wastewater recycle use. However, it was d...Mine drainage could be filtered and purified through goaf. This innovative technique shows merits, such as high treatment efficiency, remarkable economic benefit and extensive wastewater recycle use. However, it was detected that capacities of purifying mine drainage for goaf were decreased after a period of application. As a result, the effluent could not meet the standard of recycle water. To solve the problem, coagulant was considered to add into mine drainage reducing its high turbid degrees to certain level. After the preliminary flocculation treatment, mine drainage was piped into goaf to purify. In this way, the load of goaf was eased up. Its usage time was also prolonged. Therefore, this paper carried out the coagulation-flocculation jar test for mine drainage to discuss the flocculation parameters. By the experiment, 10 % iron trichloride is selected from four inorganic coagulants as the optimum coagulant. The optimum dose, PH value and sedirs6-7 and 25 min. Velocity mentation time are respectively 2 mL per 800 mL Wastewater gradient G during the process of mixing and reaction is 696 .And the value of GT is 6.264 × 10^5. The values of G and GT will supply the basis for the design of flocculation pool in the project. The flocculation parameters will be significant for the reference of practice.展开更多
基金supported by the Scientific Research Foundation of Shandong University of Science and Technology for Recruited Talents and Science Research Innovative Group of Resources and Environment Engineering College of Shandong University of Science and Technology (No. 2012ZHTD06)the Scientific Research Foundation of Shandong University of Science and Technology for Recruited Talents (No. 2013RCJJ049)+1 种基金the China Postdoctoral Science Foundation (No. 2013M541942)the Specialized Research Fund for the Doctoral Program of Higher Education (No. 20133718120013)
文摘Extraction of a coal seam which lies not far below a heating goafcan be a major safety challenge. A force auxiliary ventilation system was adopted as a control method in successful extraction and recovery of the panel 30110 of the #3-1 coal seam, which is about 30-40 rn below the heating goaf of the #2-2 seam at Longhua underground coal mine, Shanxi Province, China. Booster fans and ventilation control devices such as doors and regulators were used in the system. The results show that, provided that a force auxiliary ventilation system is properly designed to achieve a pressure balance between a panel and its overlying goat', the system can be used to extract a coal seam overlain by a heating goal. This paper describes the design, installation and performance of the ventilation system during the extraction and recovery phases of the oanel 30110.
文摘Mine drainage could be filtered and purified through goaf. This innovative technique shows merits, such as high treatment efficiency, remarkable economic benefit and extensive wastewater recycle use. However, it was detected that capacities of purifying mine drainage for goaf were decreased after a period of application. As a result, the effluent could not meet the standard of recycle water. To solve the problem, coagulant was considered to add into mine drainage reducing its high turbid degrees to certain level. After the preliminary flocculation treatment, mine drainage was piped into goaf to purify. In this way, the load of goaf was eased up. Its usage time was also prolonged. Therefore, this paper carried out the coagulation-flocculation jar test for mine drainage to discuss the flocculation parameters. By the experiment, 10 % iron trichloride is selected from four inorganic coagulants as the optimum coagulant. The optimum dose, PH value and sedirs6-7 and 25 min. Velocity mentation time are respectively 2 mL per 800 mL Wastewater gradient G during the process of mixing and reaction is 696 .And the value of GT is 6.264 × 10^5. The values of G and GT will supply the basis for the design of flocculation pool in the project. The flocculation parameters will be significant for the reference of practice.