The subject structure was consisted of a proto-type house with plan dimensions of 8 m ×4 m. A variety of materials was used to the construction, with special emphasis on using environmentally friendly non-toxic m...The subject structure was consisted of a proto-type house with plan dimensions of 8 m ×4 m. A variety of materials was used to the construction, with special emphasis on using environmentally friendly non-toxic materials. The structure's core consisted of reinforced concrete frames with masonry infill walls. Inside faces of the walls and the roof's outside face were covered with proprietary composite panels, which are manufactured with a mixture of cement, volcanic ash, and local sawmill waste. These panels were analyzed for their physical and chemical properties, as well as for their resistance to decay and insects when subjected to extreme conditions for 15 years. The panels have also shown to provide thermal insulation and nonflammable when in direct contact with fire. The roof surface was further covered with a blend of local drought-resistant succulents and cacti. This study provides a detailed review of the construction process and materials employed.展开更多
In design and construction of low/high rise buildings, different forms of construction can be applied such as concrete shear wall structural system and framed structural system without or with masonry infill walls. At...In design and construction of low/high rise buildings, different forms of construction can be applied such as concrete shear wall structural system and framed structural system without or with masonry infill walls. At present, most buildings in East Africa are constructed as reinforced concrete framed structures with strong masonry infill, but during design, engineers assume that the masonry infill panels have zero contribution in offering load resistance. Due to the problem above, a study with an objective of finding out the influence of masonry panels on the properties of reinforced concrete infilled frame under vertical load has been done. Three types of models: reinforced concrete frame model, masonry model and reinforced concrete frame with masonry infill, were investigated using finite element technique. In additional to the finite element analysis, laboratory models were prepared and tested so as to check the validity of the analytical results. The obtained results have led to an establishment of a mathematical model which may be useful to the design engineers since masonry wall panels can now be considered as load bearing elements. Such consideration of frame together with masonry leads to an accurate and optimal design of the frame, resulting into lesser amount of reinforcement and geometrical properties of the frame.展开更多
文摘The subject structure was consisted of a proto-type house with plan dimensions of 8 m ×4 m. A variety of materials was used to the construction, with special emphasis on using environmentally friendly non-toxic materials. The structure's core consisted of reinforced concrete frames with masonry infill walls. Inside faces of the walls and the roof's outside face were covered with proprietary composite panels, which are manufactured with a mixture of cement, volcanic ash, and local sawmill waste. These panels were analyzed for their physical and chemical properties, as well as for their resistance to decay and insects when subjected to extreme conditions for 15 years. The panels have also shown to provide thermal insulation and nonflammable when in direct contact with fire. The roof surface was further covered with a blend of local drought-resistant succulents and cacti. This study provides a detailed review of the construction process and materials employed.
文摘In design and construction of low/high rise buildings, different forms of construction can be applied such as concrete shear wall structural system and framed structural system without or with masonry infill walls. At present, most buildings in East Africa are constructed as reinforced concrete framed structures with strong masonry infill, but during design, engineers assume that the masonry infill panels have zero contribution in offering load resistance. Due to the problem above, a study with an objective of finding out the influence of masonry panels on the properties of reinforced concrete infilled frame under vertical load has been done. Three types of models: reinforced concrete frame model, masonry model and reinforced concrete frame with masonry infill, were investigated using finite element technique. In additional to the finite element analysis, laboratory models were prepared and tested so as to check the validity of the analytical results. The obtained results have led to an establishment of a mathematical model which may be useful to the design engineers since masonry wall panels can now be considered as load bearing elements. Such consideration of frame together with masonry leads to an accurate and optimal design of the frame, resulting into lesser amount of reinforcement and geometrical properties of the frame.