Existing nondestructive detection methods were adopted to test the compressive strength of grouted concrete block masonry,i.e.the rebound method,pulling-out method and core drilling method were employed to test the st...Existing nondestructive detection methods were adopted to test the compressive strength of grouted concrete block masonry,i.e.the rebound method,pulling-out method and core drilling method were employed to test the strength of block,mortar and grouted concrete,respectively.The suitability of these methods for the testing of strength of grouted concrete block masonry was discussed,and the comprehensive strength of block masonry was appraised by combining existing nondestructive or micro-destructive detection methods.The nondestructive detection test on 25 grouted concrete block masonry specimens was carried out.Experimental results show that these methods mentioned above are applicable for the strength detection of grouted concrete block masonry.Moreover,the formulas of compressive strength,detection methods and proposals are given as well.展开更多
To study the influence of slenderness on the axial compressive performance of autoclaved fly ash solid brick masonry columns, compression experiments were conducted on 12 samples of autoclaved fly ash solid brick maso...To study the influence of slenderness on the axial compressive performance of autoclaved fly ash solid brick masonry columns, compression experiments were conducted on 12 samples of autoclaved fly ash solid brick masonry column and 4 samples of fired clay brick masonry column. The damage patterns and compressive performance were compared and analyzed. The experimental results indicate that the compressive bearing capacity decreases as slenderness increases from 3 to 18, and the compressive bearing capacity of the autoclaved fly ash solid brick masonry columns is lower than that of the fired clay brick masonry columns. The formulae for the axial compressive bearing capacity of autoclaved fly ash solid brick masonry columns were derived based on the experiments. The nonlinear FEA program ANSYS was adopted to simulate the behaviors of masonry columns. By comparing the simulation results and experimental results, it is shown that the simulation results agree well with the experimental ones. The rationality and applicability of the simulation results were verified.展开更多
文摘Existing nondestructive detection methods were adopted to test the compressive strength of grouted concrete block masonry,i.e.the rebound method,pulling-out method and core drilling method were employed to test the strength of block,mortar and grouted concrete,respectively.The suitability of these methods for the testing of strength of grouted concrete block masonry was discussed,and the comprehensive strength of block masonry was appraised by combining existing nondestructive or micro-destructive detection methods.The nondestructive detection test on 25 grouted concrete block masonry specimens was carried out.Experimental results show that these methods mentioned above are applicable for the strength detection of grouted concrete block masonry.Moreover,the formulas of compressive strength,detection methods and proposals are given as well.
基金Supported by National Key Technology Research and Development Program (No.2008BAJ08B11-03)
文摘To study the influence of slenderness on the axial compressive performance of autoclaved fly ash solid brick masonry columns, compression experiments were conducted on 12 samples of autoclaved fly ash solid brick masonry column and 4 samples of fired clay brick masonry column. The damage patterns and compressive performance were compared and analyzed. The experimental results indicate that the compressive bearing capacity decreases as slenderness increases from 3 to 18, and the compressive bearing capacity of the autoclaved fly ash solid brick masonry columns is lower than that of the fired clay brick masonry columns. The formulae for the axial compressive bearing capacity of autoclaved fly ash solid brick masonry columns were derived based on the experiments. The nonlinear FEA program ANSYS was adopted to simulate the behaviors of masonry columns. By comparing the simulation results and experimental results, it is shown that the simulation results agree well with the experimental ones. The rationality and applicability of the simulation results were verified.