In the light of the problem of weak reflection signals shielded by strong reflections from the concrete surface,the detection and the recognition of hidden micro-cracks in the shield tunnel lining were studied using t...In the light of the problem of weak reflection signals shielded by strong reflections from the concrete surface,the detection and the recognition of hidden micro-cracks in the shield tunnel lining were studied using the orthogonal matching pursuit and the Hilbert transform(OMHT method).First,according to the matching pursuit algorithm and the strong reflection-forming mechanism,and based on the sparse representation theory,a sparse dictionary,adapted to the characteristics of the strong reflection signal,was selected,and a matching decomposition of each signal was performed so that the weak target signal submerged in the strong reflection was displayed more strongly.Second,the Hilbert transform was used to extract multiple parameters,such as the instantaneous amplitude,the instantaneous frequency,and the instantaneous phase,from the processed signal,and the ground penetrating radar(GPR)image was comprehensively analyzed and determined from multiple angles.The results show that the OMHT method can accurately weaken the effect of the strong impedance interface and effectively enhance the weak reflected signal energy of hidden micro-crack in the shield tunnel segment.The resolution of the processed GPR image is greatly improved,and the reflected signal of the hidden micro-crack is easily visible,which proves the validity and accuracy of the analysis method.展开更多
The results of investigations of compressed reinforced masonry walls subjected to axial compression are presented. Tests were carried out using specimens made of clay bricks and cement-lime mortar. As reinforcement, s...The results of investigations of compressed reinforced masonry walls subjected to axial compression are presented. Tests were carried out using specimens made of clay bricks and cement-lime mortar. As reinforcement, smooth and spiral twisted longitudinal rods, two types of structural wire mesh and truss type reinforcement were used. Two percentages of bed joint reinforcement, about 0.1% and 0.05% were applied. For each type of reinforcement, three masonry walls were tested. Additionally, nine unreinforced models were also tested. The main aim of the investigations presented is to determine the effect of different types of reinforcement on the load capacity and failure. Measurement of the strains of reinforcing bars permitted the recording of the strain level at the moment of crack appearance and also at the moment of failure.展开更多
The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2...The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2) and on polyurethane glue and also walls without mortar (dry masonry). The wall compression strength (on mortar M5 class) (per EN 1052-1:2000) amounted tofc,mv= 2.97 N/mm2 (fk = 2.48 N/mm2), elastic modulus was Ecru = 2,040 N/mm2. Various structure of bed joints and head joints were applied and the following were used as reinforcement: steel trusses of EFZ 140/Z 140 type (Z1 type) and meshes made of plastics (Z2 type). Based on the tests carried out with regard to unreinforced elements, it was shown that the filling in of head joints with mortar had an advantageous effect on the values of cracking and destruction stresses. While, with the use of reinforcement, advantageous increase of stress was obtained only when the mortar was laid twice on both bed surfaces of masonry units. The application of reinforcement in the bed joints when the mortar was laid only on one bed joints surface of the masonry units reduced the values of cracking and destruction stresses in relation to the values obtained in the unreinforced walls.展开更多
基金Projects(51678071,51608183)supported by the National Natural Science Foundation of ChinaProjects(CX2018B530,CX2018B531)supported by the Postgraduate Research and Innovation-funded Project of Hunan Province,ChinaProjects(16BCX13,16BCX09)supported by Changsha University of Science and Technology,China
文摘In the light of the problem of weak reflection signals shielded by strong reflections from the concrete surface,the detection and the recognition of hidden micro-cracks in the shield tunnel lining were studied using the orthogonal matching pursuit and the Hilbert transform(OMHT method).First,according to the matching pursuit algorithm and the strong reflection-forming mechanism,and based on the sparse representation theory,a sparse dictionary,adapted to the characteristics of the strong reflection signal,was selected,and a matching decomposition of each signal was performed so that the weak target signal submerged in the strong reflection was displayed more strongly.Second,the Hilbert transform was used to extract multiple parameters,such as the instantaneous amplitude,the instantaneous frequency,and the instantaneous phase,from the processed signal,and the ground penetrating radar(GPR)image was comprehensively analyzed and determined from multiple angles.The results show that the OMHT method can accurately weaken the effect of the strong impedance interface and effectively enhance the weak reflected signal energy of hidden micro-crack in the shield tunnel segment.The resolution of the processed GPR image is greatly improved,and the reflected signal of the hidden micro-crack is easily visible,which proves the validity and accuracy of the analysis method.
文摘The results of investigations of compressed reinforced masonry walls subjected to axial compression are presented. Tests were carried out using specimens made of clay bricks and cement-lime mortar. As reinforcement, smooth and spiral twisted longitudinal rods, two types of structural wire mesh and truss type reinforcement were used. Two percentages of bed joint reinforcement, about 0.1% and 0.05% were applied. For each type of reinforcement, three masonry walls were tested. Additionally, nine unreinforced models were also tested. The main aim of the investigations presented is to determine the effect of different types of reinforcement on the load capacity and failure. Measurement of the strains of reinforcing bars permitted the recording of the strain level at the moment of crack appearance and also at the moment of failure.
文摘The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2) and on polyurethane glue and also walls without mortar (dry masonry). The wall compression strength (on mortar M5 class) (per EN 1052-1:2000) amounted tofc,mv= 2.97 N/mm2 (fk = 2.48 N/mm2), elastic modulus was Ecru = 2,040 N/mm2. Various structure of bed joints and head joints were applied and the following were used as reinforcement: steel trusses of EFZ 140/Z 140 type (Z1 type) and meshes made of plastics (Z2 type). Based on the tests carried out with regard to unreinforced elements, it was shown that the filling in of head joints with mortar had an advantageous effect on the values of cracking and destruction stresses. While, with the use of reinforcement, advantageous increase of stress was obtained only when the mortar was laid twice on both bed surfaces of masonry units. The application of reinforcement in the bed joints when the mortar was laid only on one bed joints surface of the masonry units reduced the values of cracking and destruction stresses in relation to the values obtained in the unreinforced walls.