玄武岩纤维(BFRP)锚杆具有抗拉强度高、耐腐蚀性能好等优点,是岩土锚固结构中钢筋的良好替代品,近年颇受业界关注。通过在黄土地层中开展4组Ф25 mm BFRP锚杆和钢锚杆的现场拉拔试验,初步研究两种材质锚杆的破坏模式和锚固性能差异。研...玄武岩纤维(BFRP)锚杆具有抗拉强度高、耐腐蚀性能好等优点,是岩土锚固结构中钢筋的良好替代品,近年颇受业界关注。通过在黄土地层中开展4组Ф25 mm BFRP锚杆和钢锚杆的现场拉拔试验,初步研究两种材质锚杆的破坏模式和锚固性能差异。研究结果表明:对于诸如Ф25 mm类较大直径土层锚杆,拉拔过程中锚固体系的灌浆体内外界面破坏迹象共存,但最终破坏模式受控于灌浆体与土层界面(第二界面),且BFRP锚杆与砂浆内界面(第一界面)破坏程度明显高于钢锚杆;两种材质锚杆的极限承载力相近,界面黏结强度均随锚固长度的增大而减小;受两种材质锚杆本身的加工工艺和材料力学性能影响,试验中钢锚杆与灌浆体的黏结性能优于BFRP锚杆;相同荷载水平,相同位置处,BFRP锚杆杆体轴力大于钢锚杆,轴力衰减速率略小于钢锚杆;峰值剪应力BFRP锚杆小于钢锚杆。展开更多
In order to obtain the strength design equations for internally ring-stiffened circular hollowsection tubular DT( double tee)-joints subjected to brace axial compression or tension, theoretical and numerical studies...In order to obtain the strength design equations for internally ring-stiffened circular hollowsection tubular DT( double tee)-joints subjected to brace axial compression or tension, theoretical and numerical studies on 800 stiffened joints were conducted. Based on the failure mechanism of the stiffened joints, four theoretical models and corresponding equations for predicting the strength of the stiffeners are proposed. Combined with existing unstiffened DT-joint design equations, a design equation for the stiffened joints is proposed. The finite element analysis shows that the failure of the stiffened joints under brace axial loads can be characterized by plastic hinges forming in the stiffener and chord wall yielding in the vicinity of the brace-chord intersection. The reliability of the proposed stiffener strength equations is demonstrated by a reliability analysis. Good agreement is achieved between the stiffened joint strength calculated from the proposed joint strength equation and that obtained from finite element analysis.展开更多
Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials toget...Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials together to anchor the main steel bar. To investigate the feasibility of the proposed post-installed connections, a series of pull-out tests with different anchors were conducted for comparison,including fully adhesive anchors, partially adhesive anchors,grouting material anchoring connection and the new mixed post-installed connection. The experimental results of the single steel bar pull-out test show that the mixed post-installed connection can effectively enhance the bearing capacity of post-installed steel bars in low-strength concrete. The bearing capacity is increased by nearly two times with no cone-type concrete failure compared with the fully adhesive anchor. The results show that adopting the new mixed post-installed connection can ensure that joint performance meets the requirements if the space dimension is available.展开更多
To investigate the bearing capacity of a caisson foundation under combined vertical,horizontal and moment loadings,the three-dimensional finite element analyses of a circular caisson foundation in homogenous sandy soi...To investigate the bearing capacity of a caisson foundation under combined vertical,horizontal and moment loadings,the three-dimensional finite element analyses of a circular caisson foundation in homogenous sandy soil subjected to combined loadings are conducted.The caisson model has a depth to breadth ratio equaling one,and a soil-caisson interface friction coefficientμ=0.3.First,the responses of caisson foundations under uniaxial vertical loading V,horizontal loading H and moment loading M are examined.Moreover,the responses of caisson foundations under combined vertical-horizontal V-H,vertical-moment V-M and horizontal-moment H-M load space are studied and presented using normalized failure envelopes generated by the load-controlled method.Subsequently,the bearing behavior of caisson foundations under combined vertical-horizontal-moment V-H-M load space,as well as the kinematic mechanisms accompanying the failure under uniaxial and combined loading,are addressed and presented for different vertical load ratios V/Vu.Finally,three equations that approximate the three-dimensional shape of the failure locus are proposed,which provides a convenient means of calculating the bearing capacity of a caisson foundation subjected to uniaxial and combined vertical,horizontal and moment loadings.展开更多
This study presents the results of field and numerical investigations of lateral stiffness, capacity, and failure mechanisms for plain piles and reinforced concrete piles in soft clay. A plastic-damage model is used t...This study presents the results of field and numerical investigations of lateral stiffness, capacity, and failure mechanisms for plain piles and reinforced concrete piles in soft clay. A plastic-damage model is used to simulate concrete piles and jet-grouting in the numerical analyses. The field study and numerical investigations show that by applying jet-grouting sur- rounding the upper 7.5D (D = pile diameter) of a pile, lateral stiffness and beating capacity of the pile are increased by about 110% and 100%, respectively. This is partially because the jet-grouting increases the apparent diameter of the pile, so as to en- large the extent of failure wedge and hence passive resistance in front of the reinforced pile. Moreover, the jet-grouting pro- vides a circumferential confinement to the concrete pile, which suppresses development of tensile stress in the pile. Corre- spondingly, tension-induced plastic damage in the concrete pile is reduced, causing less degradation of stiffness and strength of the pile than that of a plain pile. Effectiveness of the circumferential confinement provided by the jet-grouting, however, diminishes once the grouting cracks because of the significant vertical and circumferential tensile stress near its mid-depth. The lateral capacity of the jet-grouting reinforced pile is, therefore, governed by mobilized passive resistance of soil and plastic damage of jet-grouting.展开更多
文摘玄武岩纤维(BFRP)锚杆具有抗拉强度高、耐腐蚀性能好等优点,是岩土锚固结构中钢筋的良好替代品,近年颇受业界关注。通过在黄土地层中开展4组Ф25 mm BFRP锚杆和钢锚杆的现场拉拔试验,初步研究两种材质锚杆的破坏模式和锚固性能差异。研究结果表明:对于诸如Ф25 mm类较大直径土层锚杆,拉拔过程中锚固体系的灌浆体内外界面破坏迹象共存,但最终破坏模式受控于灌浆体与土层界面(第二界面),且BFRP锚杆与砂浆内界面(第一界面)破坏程度明显高于钢锚杆;两种材质锚杆的极限承载力相近,界面黏结强度均随锚固长度的增大而减小;受两种材质锚杆本身的加工工艺和材料力学性能影响,试验中钢锚杆与灌浆体的黏结性能优于BFRP锚杆;相同荷载水平,相同位置处,BFRP锚杆杆体轴力大于钢锚杆,轴力衰减速率略小于钢锚杆;峰值剪应力BFRP锚杆小于钢锚杆。
基金The Open Project of State Key Laboratory of Subtropical Building Science,South China University of Technology(No.2014KB29,2015ZB30)
文摘In order to obtain the strength design equations for internally ring-stiffened circular hollowsection tubular DT( double tee)-joints subjected to brace axial compression or tension, theoretical and numerical studies on 800 stiffened joints were conducted. Based on the failure mechanism of the stiffened joints, four theoretical models and corresponding equations for predicting the strength of the stiffeners are proposed. Combined with existing unstiffened DT-joint design equations, a design equation for the stiffened joints is proposed. The finite element analysis shows that the failure of the stiffened joints under brace axial loads can be characterized by plastic hinges forming in the stiffener and chord wall yielding in the vicinity of the brace-chord intersection. The reliability of the proposed stiffener strength equations is demonstrated by a reliability analysis. Good agreement is achieved between the stiffened joint strength calculated from the proposed joint strength equation and that obtained from finite element analysis.
基金The National Natural Science Foundation of China(No.51409084)the Natural Science Foundation of Jiangsu Province(No.BK20130836)
文摘Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials together to anchor the main steel bar. To investigate the feasibility of the proposed post-installed connections, a series of pull-out tests with different anchors were conducted for comparison,including fully adhesive anchors, partially adhesive anchors,grouting material anchoring connection and the new mixed post-installed connection. The experimental results of the single steel bar pull-out test show that the mixed post-installed connection can effectively enhance the bearing capacity of post-installed steel bars in low-strength concrete. The bearing capacity is increased by nearly two times with no cone-type concrete failure compared with the fully adhesive anchor. The results show that adopting the new mixed post-installed connection can ensure that joint performance meets the requirements if the space dimension is available.
基金The National Natural Science Foundation of China(No.51808112,51878160,51678145)the Natural Science Foundation of Jiangsu Province(No.BK20180155)。
文摘To investigate the bearing capacity of a caisson foundation under combined vertical,horizontal and moment loadings,the three-dimensional finite element analyses of a circular caisson foundation in homogenous sandy soil subjected to combined loadings are conducted.The caisson model has a depth to breadth ratio equaling one,and a soil-caisson interface friction coefficientμ=0.3.First,the responses of caisson foundations under uniaxial vertical loading V,horizontal loading H and moment loading M are examined.Moreover,the responses of caisson foundations under combined vertical-horizontal V-H,vertical-moment V-M and horizontal-moment H-M load space are studied and presented using normalized failure envelopes generated by the load-controlled method.Subsequently,the bearing behavior of caisson foundations under combined vertical-horizontal-moment V-H-M load space,as well as the kinematic mechanisms accompanying the failure under uniaxial and combined loading,are addressed and presented for different vertical load ratios V/Vu.Finally,three equations that approximate the three-dimensional shape of the failure locus are proposed,which provides a convenient means of calculating the bearing capacity of a caisson foundation subjected to uniaxial and combined vertical,horizontal and moment loadings.
基金supported by the National Science Foundation for Distinguished Young Scholars of China(Grant No.51325901)the International Science and Technology Cooperation Program of China(Grant No.2015DFE72830)State Key Program of National Natural Science of China(Grant No.51338009)
文摘This study presents the results of field and numerical investigations of lateral stiffness, capacity, and failure mechanisms for plain piles and reinforced concrete piles in soft clay. A plastic-damage model is used to simulate concrete piles and jet-grouting in the numerical analyses. The field study and numerical investigations show that by applying jet-grouting sur- rounding the upper 7.5D (D = pile diameter) of a pile, lateral stiffness and beating capacity of the pile are increased by about 110% and 100%, respectively. This is partially because the jet-grouting increases the apparent diameter of the pile, so as to en- large the extent of failure wedge and hence passive resistance in front of the reinforced pile. Moreover, the jet-grouting pro- vides a circumferential confinement to the concrete pile, which suppresses development of tensile stress in the pile. Corre- spondingly, tension-induced plastic damage in the concrete pile is reduced, causing less degradation of stiffness and strength of the pile than that of a plain pile. Effectiveness of the circumferential confinement provided by the jet-grouting, however, diminishes once the grouting cracks because of the significant vertical and circumferential tensile stress near its mid-depth. The lateral capacity of the jet-grouting reinforced pile is, therefore, governed by mobilized passive resistance of soil and plastic damage of jet-grouting.