Vapor-liquid equilibrium (VLE) for a ternary system of methyldichlorosilane + methylvinyldichlorosi-lane + toluene and constituent binary systems were measured at 101.3kPa using a new type of magnetical pump-ebulliome...Vapor-liquid equilibrium (VLE) for a ternary system of methyldichlorosilane + methylvinyldichlorosi-lane + toluene and constituent binary systems were measured at 101.3kPa using a new type of magnetical pump-ebulliometer. The equilibrium compositions of the vapor phase of binary systems were calculated indirectly from the total pressure-temperature-liquid composition (pTx). The experimental data were correlated with the Wilson and NRTL(non-random two liquid) equations. The parameters of the Wilson model were employed to predict the ternary VLE data. The calculated boiling points were in good agreement with the experimental ones.展开更多
基金Supported by the Natural Science Foundation of Jiangxi Province(No.0020019).
文摘Vapor-liquid equilibrium (VLE) for a ternary system of methyldichlorosilane + methylvinyldichlorosi-lane + toluene and constituent binary systems were measured at 101.3kPa using a new type of magnetical pump-ebulliometer. The equilibrium compositions of the vapor phase of binary systems were calculated indirectly from the total pressure-temperature-liquid composition (pTx). The experimental data were correlated with the Wilson and NRTL(non-random two liquid) equations. The parameters of the Wilson model were employed to predict the ternary VLE data. The calculated boiling points were in good agreement with the experimental ones.