框架剪力墙工程加固的设计与施工 被引量:2
1
作者 李其廉 李金峰 +1 位作者 杨雪苗 张岩 《建筑技术》 北大核心 2015年第S2期340-344,共5页
河北某工程因主体验收时,部分柱混凝土强度等级达不到设计要求,进行了加固设计,论述施工方法步骤。
关键词 增大截面加固 碳纤维复合材加固 外包型钢加固
下载PDF
Mechanism of improving ductility of high strength concrete T-section beam confined by CFRP sheet subjected to flexural loading 被引量:4
2
作者 王苏岩 王泽源 《Journal of Central South University》 SCIE EI CAS 2013年第1期246-255,共10页
For the purpose of inventing a new seismic retrofitting method for the reinforced high strength concrete (HSC) T-section beam using carbon fiber reinforced polymer (CFRP) sheet, three series, a total of twelve T-s... For the purpose of inventing a new seismic retrofitting method for the reinforced high strength concrete (HSC) T-section beam using carbon fiber reinforced polymer (CFRP) sheet, three series, a total of twelve T-section beams with nine specimens confined by CFRP sheet in the plastic zone and three control beams were conducted up to failure under four-point bending test. The effectiveness of confining CFRP sheet on improving the flexural ductility of tmstrengthened T-section beams was studied. The parameters such as the width and the thickness of CFRP sheet and the type of T-section were analyzed. The experimental results show that ductility and rotation capacity of plastic hinge can be improved by the confinement of CFRP sheet, and the ductility indices increase with the increment of width and thickness of CFRP sheet. A plastic rotation model considering the width of CFRP sheet and the effect of flange of T-section beam is proposed on the basis of the model of BAKER, and the test results show a good agreement with the perdicted results. The relevant construction suggestions for seismic retrofitting design of beam-slabs system in cast-in-place framework structure are presented. 展开更多
关键词 high strength concrete fiber reinforced polymer T-section BEAM DUCTILITY plastic hinge
下载PDF
Experimental Investigatin of Cementitious Slabs Rinforced with Wired-Meshes and Continuous CFRP Slices
3
作者 Hassan Mohamed Ibrahim 《Journal of Civil Engineering and Architecture》 2010年第8期53-62,共10页
Bending tests were conducted on 23 ferrocement slab specimens with steel meshes and continuous CFRP fibers. Two, or three, or four CFRP slices are gathered as a rope and hence these ropes are arranged to form a grid t... Bending tests were conducted on 23 ferrocement slab specimens with steel meshes and continuous CFRP fibers. Two, or three, or four CFRP slices are gathered as a rope and hence these ropes are arranged to form a grid tied to a skeletal frame. The three patterns of slice reinforcement were used to reinforce cementitious slabs with or without conventional wire mesh reinforcement. The slabs were square and simply supported at their periphery with a clear span of 400 mm, and concentrically patch loaded to failure. For specimens designed to fail in flexure, the specimens reinforced with CFRP slices showed a smoother load deflection response and higher flexural capacity. For slabs designed to fail in punching shear, adding CFRP slices showed significant improvement in the ultimate shear capacity and ductility over reference specimens. Well distributed fine cracks of smaller width than control specimens were developed and no matrix spalling was observed. 展开更多
关键词 CFRP slices ferrocement slabs punching failure
下载PDF
Ductility of Timber Beams Strengthened Using Fiber Reinforced Polymer
4
作者 Yusof Ahmad 《Journal of Civil Engineering and Architecture》 2013年第5期535-544,共10页
This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm ... This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm in diameter with 10 mm spacing. The aim is to increase bonding capacity by having small studs. Five beams with the dimension of 100 mm x 200 mm x 3,000 mm were tested where one of the beams was used as control beam (unstrengthened). The remaining beams were strengthened with different configurations before tested to failure under four-point loading. The results showed that the ductility was increased as the percentage of CFRP increased. The ductility was dramatically improved where the highest ductility index based on deflection method was 2.2 where the percentage increase was 37.5%, whereas the highest ductility index based on energy method was 3.2 where the percentage increase was 88.2%. From this study, it was found that 0.3% is the optimum value of CFRP area to achieve maximum ductility index. Ductility index obtained from energy method gives higher values when compared to deflection method. All beams in this study did not fail due to peel off or debonding. It was also proved that the spikes that have been made at the wood surface were very effective for bonding. 展开更多
关键词 Carbon fiber reinforced polymer ductility index energy method.
下载PDF
Strengthening an in-service reinforcement concrete bridge with prestressed CFRP bars 被引量:3
5
作者 Hai-long WANG Wei-liang JIN +1 位作者 David J. CLELAND Ai-hui ZHANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第5期635-644,共10页
Carbon fiber reinforced polymer (CFRP) bars were prestressed for the structural strengthening of 8 T-shaped rein-forced concrete (RC) beams of a 21-year-old bridge in China. The ultimate bearing capacity of the existi... Carbon fiber reinforced polymer (CFRP) bars were prestressed for the structural strengthening of 8 T-shaped rein-forced concrete (RC) beams of a 21-year-old bridge in China. The ultimate bearing capacity of the existing bridge after retrofit was discussed on the basis of concrete structures theory. The flexural strengths of RC beams strengthened with CFRP bars were controlled by the failure of concrete in compression and a prestressing method was applied in the retrofit. The field construction processes of strengthening with CFRP bars-including grouting cracks, cutting groove, grouting epoxy and embedding CFRP bars, surface treating, banding with the U-type CFRP sheets, releasing external prestressed steel tendons-were introduced in detail. In order to evaluate the effectiveness of this strengthening method, field tests using vehicles as live load were applied before and after the retrofit. The test results of deflection and concrete strain of the T-shaped beams with and without strengthening show that the capacity of the repaired bridge, including the bending strength and stiffness, is enhanced. The measurements of crack width also indicate that this strengthening method can enhance the durability of bridges. Therefore, the proposed strengthening technology is feasible and effective. 展开更多
关键词 Carbon fiber reinforced polymer (CFRP) bar Reinforced concrete (RC) bridge Strengthening Construction pro-cedure Field test T-shaped beam