An electromagnetic anti-fouling technology(EAFT) was developed further. The operating principle of the EAFT was presented using fundamental physics laws. To validate the effect of EAFT and identify the mechanism, a ci...An electromagnetic anti-fouling technology(EAFT) was developed further. The operating principle of the EAFT was presented using fundamental physics laws. To validate the effect of EAFT and identify the mechanism, a circulating flow setup was built. A series of fouling tests were carried out with and without EAFT, measuring fouling thermal resistance as function of time, making scanning electron microscope images and analyzing the particles size distribution in solution by dynamics light scattering technology. The main results were as follows: 1) All the precipitated crystals in solution were calcite and there were little differences between with EAFT and without EAFT in the experimental range. 2) The number of precipitate nucleation in solution was small and the particle growth was slow without EAFT. In opposition to the case untreated, a rapid particle growth was observed and the number of nucleation was expected to be large, due to the fact that the EAFT effectively increases the ions and crystals collision frequency and effectiveness by utilizing the induced electric field. It is indicated that the particle growth is promoted mainly by coagulation process but not nucleation growth. 3) The EAFT could prolong the delay time of fouling greatly, and after the delay time, the thermal resistance quickly increased. Therefore, in order to mitigate scale significantly, the floccules in solution should be deposited beforehand in a low-lying area of the exchangers and let off in time.展开更多
O-nitro-phenol wastewater which contains refractory organic matters can not be degraded by conventional biological methods. In this work, o-nitro-phenol wastewater was effectively treated using magnetization-enhanced ...O-nitro-phenol wastewater which contains refractory organic matters can not be degraded by conventional biological methods. In this work, o-nitro-phenol wastewater was effectively treated using magnetization-enhanced oxidation by NaCIO solutions. The pollutant concentrations in wastewater were 250 mg/L o-nitro-phenol, 2,000 mg/L CODcr and 150 times color. The experimental results show that, using the method in this work, 94.4% o-nitro-phenol, 94.2% CODCr and 100% color can be removed at pH 6, 200 mg charcoal, 8 mL oxidizer, 5 min reaction time in 1000 mL wastewater. The treatment can be enhanced under magnetic field. CODCr and o-nitro-phenol removal can keep unchanged while the reaction time can be reduced to 3 min when the intensity of magnetic field was 60 mT.展开更多
To degrade the organic compounds in the electroplating wastewater,magnetic field was tentatively introduced into electrocatalytic oxidation on Ti-PbO2 anode.The magnetic field assisted electrocatalytic oxidation can p...To degrade the organic compounds in the electroplating wastewater,magnetic field was tentatively introduced into electrocatalytic oxidation on Ti-PbO2 anode.The magnetic field assisted electrocatalytic oxidation can promote anion movement and the generation of active species,resulting more organic compounds to be oxidized and degraded.Oxidation parameters such as treatment time,current density and initial pH of the wastewater were systematically discussed and optimized.The mineralization of organic compounds is improved by over 15% under a magnetic density of 22 mT while the current density is 50 A/m2,pH is 1.8 and the reaction time is 1.5 h.The results indicate that the magnetic field assisted electrocatalytic oxidation has considerable potential in electroplating wastewater treatment.展开更多
文摘An electromagnetic anti-fouling technology(EAFT) was developed further. The operating principle of the EAFT was presented using fundamental physics laws. To validate the effect of EAFT and identify the mechanism, a circulating flow setup was built. A series of fouling tests were carried out with and without EAFT, measuring fouling thermal resistance as function of time, making scanning electron microscope images and analyzing the particles size distribution in solution by dynamics light scattering technology. The main results were as follows: 1) All the precipitated crystals in solution were calcite and there were little differences between with EAFT and without EAFT in the experimental range. 2) The number of precipitate nucleation in solution was small and the particle growth was slow without EAFT. In opposition to the case untreated, a rapid particle growth was observed and the number of nucleation was expected to be large, due to the fact that the EAFT effectively increases the ions and crystals collision frequency and effectiveness by utilizing the induced electric field. It is indicated that the particle growth is promoted mainly by coagulation process but not nucleation growth. 3) The EAFT could prolong the delay time of fouling greatly, and after the delay time, the thermal resistance quickly increased. Therefore, in order to mitigate scale significantly, the floccules in solution should be deposited beforehand in a low-lying area of the exchangers and let off in time.
文摘O-nitro-phenol wastewater which contains refractory organic matters can not be degraded by conventional biological methods. In this work, o-nitro-phenol wastewater was effectively treated using magnetization-enhanced oxidation by NaCIO solutions. The pollutant concentrations in wastewater were 250 mg/L o-nitro-phenol, 2,000 mg/L CODcr and 150 times color. The experimental results show that, using the method in this work, 94.4% o-nitro-phenol, 94.2% CODCr and 100% color can be removed at pH 6, 200 mg charcoal, 8 mL oxidizer, 5 min reaction time in 1000 mL wastewater. The treatment can be enhanced under magnetic field. CODCr and o-nitro-phenol removal can keep unchanged while the reaction time can be reduced to 3 min when the intensity of magnetic field was 60 mT.
基金Project(2008ZX07101-006-09) supported by the Major Science and Technology Program for Water Pollution Control and Treatment of China
文摘To degrade the organic compounds in the electroplating wastewater,magnetic field was tentatively introduced into electrocatalytic oxidation on Ti-PbO2 anode.The magnetic field assisted electrocatalytic oxidation can promote anion movement and the generation of active species,resulting more organic compounds to be oxidized and degraded.Oxidation parameters such as treatment time,current density and initial pH of the wastewater were systematically discussed and optimized.The mineralization of organic compounds is improved by over 15% under a magnetic density of 22 mT while the current density is 50 A/m2,pH is 1.8 and the reaction time is 1.5 h.The results indicate that the magnetic field assisted electrocatalytic oxidation has considerable potential in electroplating wastewater treatment.