Magnetism parameters vary with the position and the speed of electromagnetic actuator's motion parts.The measurement unit presented in the paper can be applied to get the position and the speed feedback informatio...Magnetism parameters vary with the position and the speed of electromagnetic actuator's motion parts.The measurement unit presented in the paper can be applied to get the position and the speed feedback information from the measurement of electromagnetism parameters,and can constitute the untouched feedback sensing unit in the closed-loop motion control,and it adapts to the diversified feedback control of electromagnetic actuator.The digital miniaturization meter,based on MSP430 single chip processor,which can do the multi-purpose measurement of Φ & B through the menu selection,can be used for the electromagnetic actuator's performance evaluation and improvement,and also the online quality control in production process.Both real-time data graph and data table can be displayed in the meter.The paper presents the system's structure,describes the principle,discusses the working modes,and shows the software flowchart and the measuring results.展开更多
The selecting and preparing method of the basic material of magnetic fluid was introduced. By using a chemical method, the magnetic micropowder Fe 3O 4 was successfully yielded, and an oil-base as a working carrier an...The selecting and preparing method of the basic material of magnetic fluid was introduced. By using a chemical method, the magnetic micropowder Fe 3O 4 was successfully yielded, and an oil-base as a working carrier and dispers ing agent was determined. The preparation process of the magnetic fluid and prescription of the oil-base magnetic fluid were discussed. The simulation experimental rig of magnetic fluid sealing for propeller shaft was designed. The sealing ability experiment was conducted and results were analyzed. The pressure of sealing is up to 2 MPa.展开更多
Objective To evaluate the accuracy of a three-dimensional (3D) magnetic position sensor system in the quantification of ventricular stroke volumes in a dynamic model.Methods A latex balloon model of the left ventricle...Objective To evaluate the accuracy of a three-dimensional (3D) magnetic position sensor system in the quantification of ventricular stroke volumes in a dynamic model.Methods A latex balloon model of the left ventricle was suspended in a water bath connected to a pump producing 10 different pulsatile stroke volumes (15-65mi/beat). Scanning was performed using a 5.0 mHz transducer mounted with a Flock of Birds (FOB) magnetic receiver (GE System Five). The probe was scanned to sweep continuously across and over the balloon volume over 3 - 7 seconds. Digital loops were stored on magneto-optical disks and reviewed retrospectively using 3D Echopac software (GE)based on Simpson's method and compared with a two-dimensional (2D) biplane area-length method (1/2L x R) measurements at end systole and end diastole. Both 3D and 2D derived stroke volumes were compared with the reference stroke volume calculated by direct measurement of balloon capacity.Results There was an improved correlation between 3D stroke volume and reference stroke volume ( y = 0.91 x + 0.41, r = 0.97, SEE = 2.83 ml, P = 0.0001 ) compared to 2D stroke volume and reference stroke volume (y=0.49x+8.68, r=0.87, SEE=3.87 ml, P=0.0011, difference between 2D and 3D P<0.003).Conclusion 3D magnetic FOB scanning is practical, accurate and should facilitate assessment of left ventricular function.展开更多
基金Sponsored by the Multidiscipline Scientific Research Foundation of Harbin Institute of Technology(Grant No.HIT.MD2002.13).
文摘Magnetism parameters vary with the position and the speed of electromagnetic actuator's motion parts.The measurement unit presented in the paper can be applied to get the position and the speed feedback information from the measurement of electromagnetism parameters,and can constitute the untouched feedback sensing unit in the closed-loop motion control,and it adapts to the diversified feedback control of electromagnetic actuator.The digital miniaturization meter,based on MSP430 single chip processor,which can do the multi-purpose measurement of Φ & B through the menu selection,can be used for the electromagnetic actuator's performance evaluation and improvement,and also the online quality control in production process.Both real-time data graph and data table can be displayed in the meter.The paper presents the system's structure,describes the principle,discusses the working modes,and shows the software flowchart and the measuring results.
文摘The selecting and preparing method of the basic material of magnetic fluid was introduced. By using a chemical method, the magnetic micropowder Fe 3O 4 was successfully yielded, and an oil-base as a working carrier and dispers ing agent was determined. The preparation process of the magnetic fluid and prescription of the oil-base magnetic fluid were discussed. The simulation experimental rig of magnetic fluid sealing for propeller shaft was designed. The sealing ability experiment was conducted and results were analyzed. The pressure of sealing is up to 2 MPa.
文摘Objective To evaluate the accuracy of a three-dimensional (3D) magnetic position sensor system in the quantification of ventricular stroke volumes in a dynamic model.Methods A latex balloon model of the left ventricle was suspended in a water bath connected to a pump producing 10 different pulsatile stroke volumes (15-65mi/beat). Scanning was performed using a 5.0 mHz transducer mounted with a Flock of Birds (FOB) magnetic receiver (GE System Five). The probe was scanned to sweep continuously across and over the balloon volume over 3 - 7 seconds. Digital loops were stored on magneto-optical disks and reviewed retrospectively using 3D Echopac software (GE)based on Simpson's method and compared with a two-dimensional (2D) biplane area-length method (1/2L x R) measurements at end systole and end diastole. Both 3D and 2D derived stroke volumes were compared with the reference stroke volume calculated by direct measurement of balloon capacity.Results There was an improved correlation between 3D stroke volume and reference stroke volume ( y = 0.91 x + 0.41, r = 0.97, SEE = 2.83 ml, P = 0.0001 ) compared to 2D stroke volume and reference stroke volume (y=0.49x+8.68, r=0.87, SEE=3.87 ml, P=0.0011, difference between 2D and 3D P<0.003).Conclusion 3D magnetic FOB scanning is practical, accurate and should facilitate assessment of left ventricular function.