AIM: To study the changes of portal blood flow in congestive heart failure. METHODS: We studied the congestion index (CI) and portal vein pulsatility index (PI) in patients with varied degrees of congestive hear...AIM: To study the changes of portal blood flow in congestive heart failure. METHODS: We studied the congestion index (CI) and portal vein pulsatility index (PI) in patients with varied degrees of congestive heart failure using ultrasonic Doppler. Ten patients with mean right atrial pressure (RA) 〈10 mmHg were classified as group 1 and the remaining 10 patients with RA〉 10 mmHg as group 2. RESULTS: There were no difference on cardiac index (HI, P= 0.28), aortic pressure (AO, P= 0.78), left ventricular end-diastolic pressure (LVED, P=0.06), maximum portal blood velocity (Vmax, P= 0.17), mean portal blood velocity (Vmean, P=0.15) and portal blood flow volume (PBF, P= 0.95) between the two groups. Group 2 patients had higher pulmonary wedge pressure (PW, 29.9 ± 9.3 mmHg vs 14.6±7.3 mmHg, P=0.002), pulmonary arterial pressure (PA, 46.3± 13.2 mmHg vs 25.0±8.2 mmHg, P=0.004), RA (17.5±5.7 mmHg vs 4.7±2.4 mmHg, P〈 0.001), right ventricular end-diastolic pressure (RVED, 18.3±5.6 mmHg vs 6.4±2.7 mmHg, P〈0.001), CI (8.7±2.4 vs 5.8± 1.2, P=0.03), and PI (87.8±32.3% vs 27.0±7.4%, P〈0.001) than Group 1. CI was correlated with PI (P〈0.001), PW (P〈0.001), PA (P〈0.001), RA (P=0.043), RVED (P=0.005), HI (P〈0.001), AO (P〈0.001), CO (P〈0.001), LVED (P〈0.001), Vmax (P〈0.001), Vmax (P〈0.001), cross-sectional area of the main portal vein (P〈0.001) and PBF (P〈0.001). CI could be as high as 8.3 in patients with RA〈 10 mmHg and as low as 5.9 in those with RA≥10 mmHg.CONCLUSION: Our data show that RI is a more significant indicator than CI in the clinical evaluation of high RA≥ 10 mmHg, whereas CI is better than PI in the assessment of left heart function.展开更多
The measuring instrument which uses Sunplus SPCE061A MCU as the controller is a practical intelligent household heart rate meter.It can serve all people timely and effectively to detect the heart rate.It rings some vo...The measuring instrument which uses Sunplus SPCE061A MCU as the controller is a practical intelligent household heart rate meter.It can serve all people timely and effectively to detect the heart rate.It rings some voice alarm if the HRV is abnormal.Then it is decided whether to see a doctor at a convenient time for further diagnosis.The instrument has a feature of voice guidance that can save keyboard steps,which extends the scope of use.All people,old and young,the blind and the deaf,can use it by themselves.展开更多
基金Supported by the grant from the Cathay Groups,Taipei,Taiwan,China
文摘AIM: To study the changes of portal blood flow in congestive heart failure. METHODS: We studied the congestion index (CI) and portal vein pulsatility index (PI) in patients with varied degrees of congestive heart failure using ultrasonic Doppler. Ten patients with mean right atrial pressure (RA) 〈10 mmHg were classified as group 1 and the remaining 10 patients with RA〉 10 mmHg as group 2. RESULTS: There were no difference on cardiac index (HI, P= 0.28), aortic pressure (AO, P= 0.78), left ventricular end-diastolic pressure (LVED, P=0.06), maximum portal blood velocity (Vmax, P= 0.17), mean portal blood velocity (Vmean, P=0.15) and portal blood flow volume (PBF, P= 0.95) between the two groups. Group 2 patients had higher pulmonary wedge pressure (PW, 29.9 ± 9.3 mmHg vs 14.6±7.3 mmHg, P=0.002), pulmonary arterial pressure (PA, 46.3± 13.2 mmHg vs 25.0±8.2 mmHg, P=0.004), RA (17.5±5.7 mmHg vs 4.7±2.4 mmHg, P〈 0.001), right ventricular end-diastolic pressure (RVED, 18.3±5.6 mmHg vs 6.4±2.7 mmHg, P〈0.001), CI (8.7±2.4 vs 5.8± 1.2, P=0.03), and PI (87.8±32.3% vs 27.0±7.4%, P〈0.001) than Group 1. CI was correlated with PI (P〈0.001), PW (P〈0.001), PA (P〈0.001), RA (P=0.043), RVED (P=0.005), HI (P〈0.001), AO (P〈0.001), CO (P〈0.001), LVED (P〈0.001), Vmax (P〈0.001), Vmax (P〈0.001), cross-sectional area of the main portal vein (P〈0.001) and PBF (P〈0.001). CI could be as high as 8.3 in patients with RA〈 10 mmHg and as low as 5.9 in those with RA≥10 mmHg.CONCLUSION: Our data show that RI is a more significant indicator than CI in the clinical evaluation of high RA≥ 10 mmHg, whereas CI is better than PI in the assessment of left heart function.
基金supported by the National Nature Science Foundation of China(60804034)Nature Science Foundation of Shandong Province(ZR2009GQ006)+3 种基金the Project of Science and Technology of Qingdao Economic and Technological Development Area(2009-2-39)"Taishan Scholarship"Construction Engineering,Innovation Project Special Fund for PostDoctors of Shandong Province(201002028)SDUST Research Fund(2010KYJQ105)the Project of Shandong Province Higher Educational Science and Technology Program(J11LG53)
文摘The measuring instrument which uses Sunplus SPCE061A MCU as the controller is a practical intelligent household heart rate meter.It can serve all people timely and effectively to detect the heart rate.It rings some voice alarm if the HRV is abnormal.Then it is decided whether to see a doctor at a convenient time for further diagnosis.The instrument has a feature of voice guidance that can save keyboard steps,which extends the scope of use.All people,old and young,the blind and the deaf,can use it by themselves.