A new highly selective thiocyanate PVC membrane electrode based on bisbebzoin-semitriethylenetetraamine binuclear cobalt(Ⅱ) metallic complex [Co(Ⅱ) 2-BBSTA] as neutral carrier is reported, which displays an anti-Hof...A new highly selective thiocyanate PVC membrane electrode based on bisbebzoin-semitriethylenetetraamine binuclear cobalt(Ⅱ) metallic complex [Co(Ⅱ) 2-BBSTA] as neutral carrier is reported, which displays an anti-Hofmeister selectivity sequence. The electrode exhibits Nernstian potential linear range to thiocyanate from 1.0×10 -1 to 1.0×10 -6 mol/L with a detection limit 8.0×10 -7 mol/L and a slope of -52.0 mV/dec in phosphorate buffer solution of pH=5.0 at 25 ℃. The response mechanism is discussed in view of the a.c. impedance technique and the UV spectroscopy technique. The electrode based on binuclear cobalt(Ⅱ) compound was used to determine the thiocyanate content in waste water with satisfactory results.展开更多
Benzil bis(carbohydrazone)(BBC) is prepared and explored as new N N Schiff's base, which plays the role of an excellent ion carrier in the construction of a Cd(II) ion membrane sensor. The tris(2-ethylhexyl) phosp...Benzil bis(carbohydrazone)(BBC) is prepared and explored as new N N Schiff's base, which plays the role of an excellent ion carrier in the construction of a Cd(II) ion membrane sensor. The tris(2-ethylhexyl) phosphate best performance corresponds to a membrane composition of 30% poly(vinyl chloride), 65%(TEHP), 3.5% BBC and 1.5% tetradodecyl-ammoniumtetrakis(4-chlorophenyl) borate(ETH 500). This sensor shows very good selectivity and sensitivity towards cadmium ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition, selectivity, pH and influence of additive on the response properties of electrode were investigated. The response mechanism was discussed in the view of UV-spectroscopy. The electrode exhibits a Nernstian behavior(with slope of 29.7 mV per decade) over a very wide concentration range from 1.0×10?1 to 1.0×10?8 mol·L?1 with a detection limit of 3.2×10?8 mol·L?1. It shows rela-tively fast response time in whole concentration range(<8 s) and can be used for at least 10 weeks in the pH range of 2.0-9.0. The proposed sensor is successfully used for the determination of cadmium in different chocolate sam-ples and as indicator electrode in titration with ethylene diamine tetraacetate(EDTA).展开更多
PVC (a poly vinyl chloride) membrane was prepared by using phenyl disulfide as a carrier for selective determination of Pd (II) ion. The membrane can be worked well over a wide concentration range (1.0 × 106...PVC (a poly vinyl chloride) membrane was prepared by using phenyl disulfide as a carrier for selective determination of Pd (II) ion. The membrane can be worked well over a wide concentration range (1.0 × 106-1.0 × 10-1) M with a slope 29.53 mV/decade and a limit of detection (1.77× 10-7) M. The measured of response time was 9 s. It was found to be selective and useable within the pH range (3.0-7.0). The lifetime of membrane sensor prepared could be used for at least 4 months. The electrode was successfully used as an indicator electrode in potentiometric titration of palladium ion with EDTA.展开更多
Organic soft actuators are of special interest in many fields including intravascular neurosurgery. Ion conductive polymer film (ICPF) actuators have been one of the strong candidates. The ICPF investigated here was...Organic soft actuators are of special interest in many fields including intravascular neurosurgery. Ion conductive polymer film (ICPF) actuators have been one of the strong candidates. The ICPF investigated here was a cation-exchange membrane (Nation 117, Du Pont). When a voltage is given between the metal eIectrodes of an ICPF actuator, the ICPF actuator bends in the water due to the motion of Li+ cations with associated water. In order to increase the freedom of the deformation of the ICPF actuator, structures of independent electrode pairs were proposed. The electrodes were selectively deposited by non-electrokvzed plating including the Pt [(NH3)6]^4+ deposition process in a [Pt(NH3)6]Cl4 solution and the reduction process in a NaBH4 solution. Here, an elastomer adhesive tape with a fine electrode patterns was used performances were reported in detail. as a mask. The actuators processing conditions and their actuator展开更多
以CO_3^(2-)为检测对象,发展了聚合物敏感膜电位型碳酸根传感器。采用3-辛基噻吩(POT)作为传导层的固体接触式电极技术,通过优化实验条件,构建了聚合物敏感膜CO_3^(2-)选择性电极,该电极对CO_3^(2-)检出限为7.0μmol/L,线性范围为1.0...以CO_3^(2-)为检测对象,发展了聚合物敏感膜电位型碳酸根传感器。采用3-辛基噻吩(POT)作为传导层的固体接触式电极技术,通过优化实验条件,构建了聚合物敏感膜CO_3^(2-)选择性电极,该电极对CO_3^(2-)检出限为7.0μmol/L,线性范围为1.0×10^(-5)~1.0×10^(-3)mol/L,能斯特响应斜率为-29.6 m V/decade。传感器已用于海水中CO_3^(2-)的测定。展开更多
Plasma-synthesized cobalt oxide supported on carbon has been analyzed for its use for electrocatalytic oxygen reduction reaction (ORR) in alkaline anion exchange membrane fuel cells (AEMFC). This work presents the...Plasma-synthesized cobalt oxide supported on carbon has been analyzed for its use for electrocatalytic oxygen reduction reaction (ORR) in alkaline anion exchange membrane fuel cells (AEMFC). This work presents the ORR activity in 0.1 mol L-1 KOH and 0.1 tool L-1 K2CO3 at 25 ℃. Cyclic voltammetry (CV) was used to determine the potentials at which the ORR occurs and to evaluate the stability of catalyst. Moreover, a rotating ring-disk electrode (RRDE) was used to investigate the activity of the catalysts and the formation of the by-product hydroperoxide anion (HO2-) as well as to identify the preferred pathway of the ORR. Calculated kinetic parameters for the ORR for the cobalt catalysts are shown in this work together with a comparison to a commercial platinum catalyst. However, the cobalt oxide produced more by-products which could lead to damage of the membrane in a fuel cell through a radical attack of the polymer backbone.展开更多
文摘A new highly selective thiocyanate PVC membrane electrode based on bisbebzoin-semitriethylenetetraamine binuclear cobalt(Ⅱ) metallic complex [Co(Ⅱ) 2-BBSTA] as neutral carrier is reported, which displays an anti-Hofmeister selectivity sequence. The electrode exhibits Nernstian potential linear range to thiocyanate from 1.0×10 -1 to 1.0×10 -6 mol/L with a detection limit 8.0×10 -7 mol/L and a slope of -52.0 mV/dec in phosphorate buffer solution of pH=5.0 at 25 ℃. The response mechanism is discussed in view of the a.c. impedance technique and the UV spectroscopy technique. The electrode based on binuclear cobalt(Ⅱ) compound was used to determine the thiocyanate content in waste water with satisfactory results.
文摘Benzil bis(carbohydrazone)(BBC) is prepared and explored as new N N Schiff's base, which plays the role of an excellent ion carrier in the construction of a Cd(II) ion membrane sensor. The tris(2-ethylhexyl) phosphate best performance corresponds to a membrane composition of 30% poly(vinyl chloride), 65%(TEHP), 3.5% BBC and 1.5% tetradodecyl-ammoniumtetrakis(4-chlorophenyl) borate(ETH 500). This sensor shows very good selectivity and sensitivity towards cadmium ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition, selectivity, pH and influence of additive on the response properties of electrode were investigated. The response mechanism was discussed in the view of UV-spectroscopy. The electrode exhibits a Nernstian behavior(with slope of 29.7 mV per decade) over a very wide concentration range from 1.0×10?1 to 1.0×10?8 mol·L?1 with a detection limit of 3.2×10?8 mol·L?1. It shows rela-tively fast response time in whole concentration range(<8 s) and can be used for at least 10 weeks in the pH range of 2.0-9.0. The proposed sensor is successfully used for the determination of cadmium in different chocolate sam-ples and as indicator electrode in titration with ethylene diamine tetraacetate(EDTA).
文摘PVC (a poly vinyl chloride) membrane was prepared by using phenyl disulfide as a carrier for selective determination of Pd (II) ion. The membrane can be worked well over a wide concentration range (1.0 × 106-1.0 × 10-1) M with a slope 29.53 mV/decade and a limit of detection (1.77× 10-7) M. The measured of response time was 9 s. It was found to be selective and useable within the pH range (3.0-7.0). The lifetime of membrane sensor prepared could be used for at least 4 months. The electrode was successfully used as an indicator electrode in potentiometric titration of palladium ion with EDTA.
文摘Organic soft actuators are of special interest in many fields including intravascular neurosurgery. Ion conductive polymer film (ICPF) actuators have been one of the strong candidates. The ICPF investigated here was a cation-exchange membrane (Nation 117, Du Pont). When a voltage is given between the metal eIectrodes of an ICPF actuator, the ICPF actuator bends in the water due to the motion of Li+ cations with associated water. In order to increase the freedom of the deformation of the ICPF actuator, structures of independent electrode pairs were proposed. The electrodes were selectively deposited by non-electrokvzed plating including the Pt [(NH3)6]^4+ deposition process in a [Pt(NH3)6]Cl4 solution and the reduction process in a NaBH4 solution. Here, an elastomer adhesive tape with a fine electrode patterns was used performances were reported in detail. as a mask. The actuators processing conditions and their actuator
文摘以CO_3^(2-)为检测对象,发展了聚合物敏感膜电位型碳酸根传感器。采用3-辛基噻吩(POT)作为传导层的固体接触式电极技术,通过优化实验条件,构建了聚合物敏感膜CO_3^(2-)选择性电极,该电极对CO_3^(2-)检出限为7.0μmol/L,线性范围为1.0×10^(-5)~1.0×10^(-3)mol/L,能斯特响应斜率为-29.6 m V/decade。传感器已用于海水中CO_3^(2-)的测定。
文摘Plasma-synthesized cobalt oxide supported on carbon has been analyzed for its use for electrocatalytic oxygen reduction reaction (ORR) in alkaline anion exchange membrane fuel cells (AEMFC). This work presents the ORR activity in 0.1 mol L-1 KOH and 0.1 tool L-1 K2CO3 at 25 ℃. Cyclic voltammetry (CV) was used to determine the potentials at which the ORR occurs and to evaluate the stability of catalyst. Moreover, a rotating ring-disk electrode (RRDE) was used to investigate the activity of the catalysts and the formation of the by-product hydroperoxide anion (HO2-) as well as to identify the preferred pathway of the ORR. Calculated kinetic parameters for the ORR for the cobalt catalysts are shown in this work together with a comparison to a commercial platinum catalyst. However, the cobalt oxide produced more by-products which could lead to damage of the membrane in a fuel cell through a radical attack of the polymer backbone.