The interaction radius of a resonance is an important physical quantity to describe the structure of a resonance. But, for a long time, physicists do not find a reliable way to measure the magnitude of the interaction...The interaction radius of a resonance is an important physical quantity to describe the structure of a resonance. But, for a long time, physicists do not find a reliable way to measure the magnitude of the interaction radius of a resonance. In this paper, a method is proposed to measure the interaction radius in physics analysis. It is found that the centrifugal barrier effects have great influence to physical results obtained in the PWA fit, and the interaction radius of some resonances can be well measured in the fit.展开更多
This paper presents the unsteady data acquisition system used to measure the pressure field in high speed compressors.Details and electronic sketches are given for the conditioners developed in-house that have been us...This paper presents the unsteady data acquisition system used to measure the pressure field in high speed compressors.Details and electronic sketches are given for the conditioners developed in-house that have been used to amplify and to filter the pressure signal with the aim of acquiring data up to 150 kHz.A discussion of the experimental results carried out in a centrifugal compressor is proposed.Through different processing of the pressure signals and a comparison with URANS simulations,the excitation of the pressure transducers by the pressure waves generated by shock waves that occur between the impeller and the diffuser is highlighted.The levels of pressure fluctuations measured when entering into surge are also presented and reveal very repetitive behaviour of the flow instabilities.展开更多
文摘The interaction radius of a resonance is an important physical quantity to describe the structure of a resonance. But, for a long time, physicists do not find a reliable way to measure the magnitude of the interaction radius of a resonance. In this paper, a method is proposed to measure the interaction radius in physics analysis. It is found that the centrifugal barrier effects have great influence to physical results obtained in the PWA fit, and the interaction radius of some resonances can be well measured in the fit.
基金the company Turbomeca which supports the centrifugal compressor research program
文摘This paper presents the unsteady data acquisition system used to measure the pressure field in high speed compressors.Details and electronic sketches are given for the conditioners developed in-house that have been used to amplify and to filter the pressure signal with the aim of acquiring data up to 150 kHz.A discussion of the experimental results carried out in a centrifugal compressor is proposed.Through different processing of the pressure signals and a comparison with URANS simulations,the excitation of the pressure transducers by the pressure waves generated by shock waves that occur between the impeller and the diffuser is highlighted.The levels of pressure fluctuations measured when entering into surge are also presented and reveal very repetitive behaviour of the flow instabilities.