Background P-wave dispersion (PWD), a measure of heterogeneity of atrial refractoriness, is defined as the difference between the maximum and minimum P-wave duration. In patients with severe aortic stenosis (AS), ...Background P-wave dispersion (PWD), a measure of heterogeneity of atrial refractoriness, is defined as the difference between the maximum and minimum P-wave duration. In patients with severe aortic stenosis (AS), P-wave duration and PWD were shown to be increased, indicating atrial electrical remodeling. However, the effect of transcatheter aortic valve replacement (TAVR) on P-wave morphology has not been established yet. The aim of this study is to assess the short and long-term effects of TAVR with two types of bioprosthetic valves on P-wave duration and PWD in association with left atrial (LA) size. Methods Fifty-two (36 female) eligible patients in sinus rhythm who underwent transfemoral TAVR between June 01, 2012 and July 31, 2014 with either a Medtronic CoreValve (MCV) (n = 32) or an Edwards SAPIEN XT Valve (n = 20) were enrolled. Standard 12-lead electrocardiogram and echocardiographic evaluations were per- formed pre-procedurally, post-TAVR day one and 6 months post-TAVR. P-wave duration and PWD were measured and correlation analyses with echocardiographic variables were performed. Results P-wave duration and PWD were significantly decreased on post-TAVR day one (P 〈 0.05). They continued to decrease during the six month follow-up period, but were not significantly different from short-term values (P 〉 0.05). The decrease of LA diameter was found significant at the sixth-months of follow-up (P 〈 0.05). These changes were independent from the types of bioprosthetic valves implanted (P 〉 0.05). A positive correlation was detected between minimum P-wave duration and maximum aortic valve gradients at post-TAVR day one (r = 0.297, P = 0.032). Conclusions P-wave duration and PWD were significantly reduced early after TAVR indicating early reverse atrial electrical remodeling. Moreover, structural reverse remodeling of atrium was detected at the 6-months of follow-up. The effects of two types of bioprosthetic valves on atrial remodeling were similar.展开更多
The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of tra...The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of transcatheter aortic valve replacement (TAVR) procedure on atrial electrical remodeling. In this study, TAVR procedure led to a decrease on P-wave duration and P-wave dinner,inn展开更多
文摘Background P-wave dispersion (PWD), a measure of heterogeneity of atrial refractoriness, is defined as the difference between the maximum and minimum P-wave duration. In patients with severe aortic stenosis (AS), P-wave duration and PWD were shown to be increased, indicating atrial electrical remodeling. However, the effect of transcatheter aortic valve replacement (TAVR) on P-wave morphology has not been established yet. The aim of this study is to assess the short and long-term effects of TAVR with two types of bioprosthetic valves on P-wave duration and PWD in association with left atrial (LA) size. Methods Fifty-two (36 female) eligible patients in sinus rhythm who underwent transfemoral TAVR between June 01, 2012 and July 31, 2014 with either a Medtronic CoreValve (MCV) (n = 32) or an Edwards SAPIEN XT Valve (n = 20) were enrolled. Standard 12-lead electrocardiogram and echocardiographic evaluations were per- formed pre-procedurally, post-TAVR day one and 6 months post-TAVR. P-wave duration and PWD were measured and correlation analyses with echocardiographic variables were performed. Results P-wave duration and PWD were significantly decreased on post-TAVR day one (P 〈 0.05). They continued to decrease during the six month follow-up period, but were not significantly different from short-term values (P 〉 0.05). The decrease of LA diameter was found significant at the sixth-months of follow-up (P 〈 0.05). These changes were independent from the types of bioprosthetic valves implanted (P 〉 0.05). A positive correlation was detected between minimum P-wave duration and maximum aortic valve gradients at post-TAVR day one (r = 0.297, P = 0.032). Conclusions P-wave duration and PWD were significantly reduced early after TAVR indicating early reverse atrial electrical remodeling. Moreover, structural reverse remodeling of atrium was detected at the 6-months of follow-up. The effects of two types of bioprosthetic valves on atrial remodeling were similar.
文摘The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of transcatheter aortic valve replacement (TAVR) procedure on atrial electrical remodeling. In this study, TAVR procedure led to a decrease on P-wave duration and P-wave dinner,inn