Background Corrected QT dispersion (cQTD) has been correlated with non-uniform ventricular repolarisation and increased mortality. In patients with aortic stenosis, cQTD has been shown improved after surgical valve ...Background Corrected QT dispersion (cQTD) has been correlated with non-uniform ventricular repolarisation and increased mortality. In patients with aortic stenosis, cQTD has been shown improved after surgical valve replacement, but the effects of transcatheter aortic valve implantation (TAVI) are unknown. Therefore, we sought to explore the frequency, predictors and prognostic effects of defective cQTD recovery at 6 months after TAVI. Methods A total of 222 patients underwent TAVI with the Medtronic-CoreValve System between November 2005 and January 2012. Patients who were on class Ⅰ or Ⅲ antiarrhythmics or on chronic haemodialysis or who developed atrial fibrillation, a new bundle branch block or became pacemaker dependent after TAVI were excluded. As a result, pre-, post- and follow-up ECG (median: 6 months) analysis was available in 45 eligible patients. Defective cQTD recovery was defined as any progression beyond the baseline cQTD at 6 months. Results In the 45 patients, the mean cQTD was 47 ± 23 ms at baseline, 45 ±17 ms immediately after TAVI and 40 ± 16 ms at 6 months (15% reduction, P = 0.049). Compared to baseline, cQTD at 6 months was improved in 60% of the patients whereas defective cQTD recovery was present in 40%. cQTD increase immediately after TAVI was an independent predictor of defective cQTD recovery at 6 months (per 10 ms increase; OR: 1.89, 95% CI: 1.15-3.12). By univariable analysis, defective cQTD recovery was associated with late mortality (HR: 1.52, 95% CI: 1.05-2.17). Conclusions Despite a gradual reduction ofcQTD after TAVI, 40% of the patients had defective recovery at 6 months which was associated with late mortality. More detailed ECG analysis after TAVI may help to avoid late death.展开更多
We propose a procedure to generalize the Husimi distribution to systems with continuous spectrum. We start examining a pioneering work, by Gazeau and Klauder, where the concept of coherent states for systems with disc...We propose a procedure to generalize the Husimi distribution to systems with continuous spectrum. We start examining a pioneering work, by Gazeau and Klauder, where the concept of coherent states for systems with discrete spectrum was extended to systems with continuous one. In the present article, we see the Husimi distribution as a representation of the density operator in terms of a basis of coherent states. There are other ways to obtain it, but we do not consider here. We specially discuss the problem of the continuous harmonic oscillator.展开更多
文摘Background Corrected QT dispersion (cQTD) has been correlated with non-uniform ventricular repolarisation and increased mortality. In patients with aortic stenosis, cQTD has been shown improved after surgical valve replacement, but the effects of transcatheter aortic valve implantation (TAVI) are unknown. Therefore, we sought to explore the frequency, predictors and prognostic effects of defective cQTD recovery at 6 months after TAVI. Methods A total of 222 patients underwent TAVI with the Medtronic-CoreValve System between November 2005 and January 2012. Patients who were on class Ⅰ or Ⅲ antiarrhythmics or on chronic haemodialysis or who developed atrial fibrillation, a new bundle branch block or became pacemaker dependent after TAVI were excluded. As a result, pre-, post- and follow-up ECG (median: 6 months) analysis was available in 45 eligible patients. Defective cQTD recovery was defined as any progression beyond the baseline cQTD at 6 months. Results In the 45 patients, the mean cQTD was 47 ± 23 ms at baseline, 45 ±17 ms immediately after TAVI and 40 ± 16 ms at 6 months (15% reduction, P = 0.049). Compared to baseline, cQTD at 6 months was improved in 60% of the patients whereas defective cQTD recovery was present in 40%. cQTD increase immediately after TAVI was an independent predictor of defective cQTD recovery at 6 months (per 10 ms increase; OR: 1.89, 95% CI: 1.15-3.12). By univariable analysis, defective cQTD recovery was associated with late mortality (HR: 1.52, 95% CI: 1.05-2.17). Conclusions Despite a gradual reduction ofcQTD after TAVI, 40% of the patients had defective recovery at 6 months which was associated with late mortality. More detailed ECG analysis after TAVI may help to avoid late death.
基金partial financial support by FONDECYT, under Grant No. 1080487
文摘We propose a procedure to generalize the Husimi distribution to systems with continuous spectrum. We start examining a pioneering work, by Gazeau and Klauder, where the concept of coherent states for systems with discrete spectrum was extended to systems with continuous one. In the present article, we see the Husimi distribution as a representation of the density operator in terms of a basis of coherent states. There are other ways to obtain it, but we do not consider here. We specially discuss the problem of the continuous harmonic oscillator.