Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computatio...Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results.展开更多
The section shape of an assembled magnetic medium is the most important structural parameter of a high gradient magnetic separator, which directly affects the induction distribution and magnetic field gradient of the ...The section shape of an assembled magnetic medium is the most important structural parameter of a high gradient magnetic separator, which directly affects the induction distribution and magnetic field gradient of the magnetic separator. In this study, equilateral triangle, square, hexagonal, octagon, dodecagon, and round shape sections of the assembled magnetic medium are chosen to study their influence on magnetic field distribution characteristics using the ANSYS analysis. This paper utilizes a single assembled magnetic medium to understand the relationship between the geometry of the assembled magnetic medium and its magnetic field distribution characteristics. The results show that high magnetic field,regional field, magnetic field gradient, and magnetic force formed by the different sections of the assembled magnetic medium in the same background magnetic field reduce in turn based on the triangle,square, hexagonal, octagon, dodecagon, and round. Based on the magnetic field characteristics analytic results, the magnetic separation tests of the ilmenite are carried out. The results indicate that the section shape of the toothed plate compared with the section shape of cylinder can improve the recovery of ilmenite up to 45% in the same magnetizing current condition of 2A, which is consistent with magnetic field characteristics analysis of different assembled magnetic medium section shapes.展开更多
Based on the analysis of high-speed video images, the detachment behavior of dust cake from the ceramic candle filter surface during pulse cleaning process is investigated. The influences of the dust cake loading,the ...Based on the analysis of high-speed video images, the detachment behavior of dust cake from the ceramic candle filter surface during pulse cleaning process is investigated. The influences of the dust cake loading,the reservoir pressure, and the filtration velocity on the cleaning effectiveness are analyzed. Experimental results show that there exists an optimum dust cake thickness for pulse-cleaning process. For thin dust cake, the patchy cleaning exists and the cleaning efficiency is low; if the dust cake is too thick, the pressure drop across the dust cake becomes higher and a higher reservoir pressure may be needed. At the same time there also exists an optimum reservoir pressure for a given filtration condition.展开更多
A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined b...A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined by making thin layer. This method had a high sensitivity (ε620= 3.0×10^5L/mol.cm), which was 15 times higher than that of liquid phase spectrophotometry. It had been proved a satisfactory precision (5.01μg Fe, n=6, RSD=1.8%). The trace Fe in natural water was determined and the recovery was 97%.展开更多
The purpose of this study is to establish the high-accurate prediction method of particle separation in a cyclone separator. Numerical simulation of the swirling flows in a cyclone separator is performed by using a la...The purpose of this study is to establish the high-accurate prediction method of particle separation in a cyclone separator. Numerical simulation of the swirling flows in a cyclone separator is performed by using a large eddy simulation (LES) based on a Smagorinsky model. The validity of the simulation and the complicated flow characteristics are discussed by comparison with experimental results. Moreover, particle motions are treated by a Lagrangian method and are calculated with a one-way method. A performance for particle separation is predicted from the results of the particle tracing. As results of our investigation, the influences of the inserted height of the outlet pipe on the performance for particle separation of cyclone separator are shown.展开更多
For the design of pressurized circulating fluidized beds, experiments were conducted in a small cyclone with 120 mm in diameter and 300 mm in height at high pressures and at atmospheric temperatures. Influence of air ...For the design of pressurized circulating fluidized beds, experiments were conducted in a small cyclone with 120 mm in diameter and 300 mm in height at high pressures and at atmospheric temperatures. Influence of air leakage from the stand pipe into the cyclone was specially focused. A semi-empirical model was developed for the prediction of the pressure drop of the cyclone separator at different operate pressures with the effect of air leakage and inlet solid loading. The operate pressure, air leakage and inlet solid loading act as significant roles in cyclone pressure drop. The pressure drop increases with the increasing of pressure and decreases with the increasing of the flow rate of air leakage from the standpipe and with the increasing of the inlet solid loading.展开更多
This study presents a numerical simulation of the stall and surge in a centrifugal compressor and presents a description of the stall development in two different cases.The first case is for a compressor with vaneless...This study presents a numerical simulation of the stall and surge in a centrifugal compressor and presents a description of the stall development in two different cases.The first case is for a compressor with vaneless diffuser and the second is for a compressor with vaned diffuser of the vane island shape.The main aim of this study is to compare the flow characteristics and behavior for the two compressors near the surge operating condition and provide further understanding of the diffuser role when back flow occurs at surge.Results showed that for a location near the diffuser entrance,the amplitude of the static pressure fluctuations for the vaneless diffuser case is higher than that for the vaned diffuser case near surge condition.These pressure fluctuations in the case of the vaneless diffuser appear with a gradual decrease of the mean pressure value as a part of the surge cycle.While for the case of the vaned diffuser,the pressure drop during surge occurs faster than the case of the vaneless diffuser.Also,results indicated that during surge in the case of vaneless diffuser,there is a region with low velocity and back flow that appears as a layer connecting all impeller passages near shroud surface and this layer develops in size with time.On the other hand,for the case of vaned diffuser during surge,the low velocity regions appear in random locations in some passages and these regions expand with time towards the shroud surface.Results showed that during stall,the impeller passages are exposed to identical impact from stall cells in the case of vaneless diffuser while the stall effect varies from passage to another in the case of the vaned diffuser.展开更多
基金Supported by the National Natural Science Foundation of China (60672151, 60532020).
文摘Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results.
基金provided by the Postdoctoral Science Foundation of China(No.2013M542076)the self-determined and innovative research funds of WUT(No.2014-IV-069)the Ministry of Science and Technology of China(No.2011BAB05B01)
文摘The section shape of an assembled magnetic medium is the most important structural parameter of a high gradient magnetic separator, which directly affects the induction distribution and magnetic field gradient of the magnetic separator. In this study, equilateral triangle, square, hexagonal, octagon, dodecagon, and round shape sections of the assembled magnetic medium are chosen to study their influence on magnetic field distribution characteristics using the ANSYS analysis. This paper utilizes a single assembled magnetic medium to understand the relationship between the geometry of the assembled magnetic medium and its magnetic field distribution characteristics. The results show that high magnetic field,regional field, magnetic field gradient, and magnetic force formed by the different sections of the assembled magnetic medium in the same background magnetic field reduce in turn based on the triangle,square, hexagonal, octagon, dodecagon, and round. Based on the magnetic field characteristics analytic results, the magnetic separation tests of the ilmenite are carried out. The results indicate that the section shape of the toothed plate compared with the section shape of cylinder can improve the recovery of ilmenite up to 45% in the same magnetizing current condition of 2A, which is consistent with magnetic field characteristics analysis of different assembled magnetic medium section shapes.
基金Supported by the National Natural Science Foundation of China (No. 50376042)Doctoral Program Foundation of Institute of Higher Education of China (20040425007).
文摘Based on the analysis of high-speed video images, the detachment behavior of dust cake from the ceramic candle filter surface during pulse cleaning process is investigated. The influences of the dust cake loading,the reservoir pressure, and the filtration velocity on the cleaning effectiveness are analyzed. Experimental results show that there exists an optimum dust cake thickness for pulse-cleaning process. For thin dust cake, the patchy cleaning exists and the cleaning efficiency is low; if the dust cake is too thick, the pressure drop across the dust cake becomes higher and a higher reservoir pressure may be needed. At the same time there also exists an optimum reservoir pressure for a given filtration condition.
文摘A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined by making thin layer. This method had a high sensitivity (ε620= 3.0×10^5L/mol.cm), which was 15 times higher than that of liquid phase spectrophotometry. It had been proved a satisfactory precision (5.01μg Fe, n=6, RSD=1.8%). The trace Fe in natural water was determined and the recovery was 97%.
文摘The purpose of this study is to establish the high-accurate prediction method of particle separation in a cyclone separator. Numerical simulation of the swirling flows in a cyclone separator is performed by using a large eddy simulation (LES) based on a Smagorinsky model. The validity of the simulation and the complicated flow characteristics are discussed by comparison with experimental results. Moreover, particle motions are treated by a Lagrangian method and are calculated with a one-way method. A performance for particle separation is predicted from the results of the particle tracing. As results of our investigation, the influences of the inserted height of the outlet pipe on the performance for particle separation of cyclone separator are shown.
基金Financial support from The Ministry of Science and Technology of China (Contract No.2003AA529220)
文摘For the design of pressurized circulating fluidized beds, experiments were conducted in a small cyclone with 120 mm in diameter and 300 mm in height at high pressures and at atmospheric temperatures. Influence of air leakage from the stand pipe into the cyclone was specially focused. A semi-empirical model was developed for the prediction of the pressure drop of the cyclone separator at different operate pressures with the effect of air leakage and inlet solid loading. The operate pressure, air leakage and inlet solid loading act as significant roles in cyclone pressure drop. The pressure drop increases with the increasing of pressure and decreases with the increasing of the flow rate of air leakage from the standpipe and with the increasing of the inlet solid loading.
基金NPRP grant No.4-651-2-242 from the Qatar National Research Fund (a member of Qatar Foundation)
文摘This study presents a numerical simulation of the stall and surge in a centrifugal compressor and presents a description of the stall development in two different cases.The first case is for a compressor with vaneless diffuser and the second is for a compressor with vaned diffuser of the vane island shape.The main aim of this study is to compare the flow characteristics and behavior for the two compressors near the surge operating condition and provide further understanding of the diffuser role when back flow occurs at surge.Results showed that for a location near the diffuser entrance,the amplitude of the static pressure fluctuations for the vaneless diffuser case is higher than that for the vaned diffuser case near surge condition.These pressure fluctuations in the case of the vaneless diffuser appear with a gradual decrease of the mean pressure value as a part of the surge cycle.While for the case of the vaned diffuser,the pressure drop during surge occurs faster than the case of the vaneless diffuser.Also,results indicated that during surge in the case of vaneless diffuser,there is a region with low velocity and back flow that appears as a layer connecting all impeller passages near shroud surface and this layer develops in size with time.On the other hand,for the case of vaned diffuser during surge,the low velocity regions appear in random locations in some passages and these regions expand with time towards the shroud surface.Results showed that during stall,the impeller passages are exposed to identical impact from stall cells in the case of vaneless diffuser while the stall effect varies from passage to another in the case of the vaned diffuser.