In this study,we report the design and simulation of an electrostatic ion lens system consisting of 22 round metal plates.The opening of the extractor plate is covered withmetal mesh,which is for shielding the interac...In this study,we report the design and simulation of an electrostatic ion lens system consisting of 22 round metal plates.The opening of the extractor plate is covered withmetal mesh,which is for shielding the interaction region of the lens system from the high DC voltages applied to all other plates than the repeller and extractor plates.The Simion simulation shows that both velocity-mapping and time focusing can be achieved simultaneously when appropriate voltages are applied to each of the plates.This makes the ion lens system be able to focus large ionic volumes in all three dimensions,which is an essential requirement for crossed ion-molecule scattering studies.A three-dimensional ion velocity measurement system with multi-hit and potential multi-mass capability is built,which consists of a microchannel plate(MCP),a P47 phosphor screen,a CMOS camera,a fast photomultiplier tube(PMT),and a high-speed digitizer.The two velocity components perpendicular to the flight axis are measured by the CMOS camera,and the time-of-flight,from which the velocity component along the flight axis can be deduced,is measured by the PMT.A Labview program is written to combine the two measurements for building the full three-dimensional ion velocity in real time on a frame-by-frame basis.The multi-hit capability comes from the fact that multiple ions from the camera and PMT in the same frame can be correlated with each other based on their various intensities.We demonstrate this by using the photodissociation of CH31 at 304 nm.展开更多
OBJECTIVE: To investigate the characteristics of multifocal electroretinograms (mf-ERG) of different phases in diabetic retinopathy (DR) and its clinical significance. METHODS: Multifocal electroretinograms in patient...OBJECTIVE: To investigate the characteristics of multifocal electroretinograms (mf-ERG) of different phases in diabetic retinopathy (DR) and its clinical significance. METHODS: Multifocal electroretinograms in patients with DR (I - II stage) were tested with VERIS IV system. RESULTS: In I - II stage, the absolute values of N1, P1 and N2 response densities, and the N1-P1 and P1-N2 response densities were attenuated is a field of about 45 degrees in diameter. CONCLUSION: As a new objective and quantitative examination for spatial visual function, multifocal electroretinograms may be valuable in the diagnosis of diabetic retinopathy.展开更多
To investigate the characteristics of multifocal electroretinograms (mf ERG) o f different phases in diabetic retinopathy (DR) and its clinical significance Methods Multifocal electroretinograms in patients with D...To investigate the characteristics of multifocal electroretinograms (mf ERG) o f different phases in diabetic retinopathy (DR) and its clinical significance Methods Multifocal electroretinograms in patients with DR (Ⅰ-Ⅱ stage) were tested with VERIS Ⅳ system Results In Ⅰ-Ⅱ stage, the absolute values of N1, P1 and N2 response densities, and the N1 P1 and P1 N2 response densities were attenuated is a field of about 45 deg rees in diameter Conclusion As a new ABSTRACT and quantitative examination for spatial visual function, mul tifocal electroretinograms may be valuable in the diagnosis of diabetic retinopa thy展开更多
To investigate the pathological morphology alteration of the splanchnic vascular wall in portal hypertensive patients Methods Splenic arteries, veins and gastric coronary veins from portal hypertensive pati ents (n...To investigate the pathological morphology alteration of the splanchnic vascular wall in portal hypertensive patients Methods Splenic arteries, veins and gastric coronary veins from portal hypertensive pati ents (n=50) were removed during esophagogastric devascularization with splenecto my and were observed under optic and electron microscopes The expression of iN OS in the splenic artery wall was analysed with immunohistochemistry Results The internal elastic membrane and medial elastic fibers of the splenic artery wa ll were broken and degenerated Atrophy, apoptosis and phenotypic changes were seen in smooth muscle cells of splenic arteries Positive staining for iNOS was seen in the cytoplasm of smooth muscle cells and iNOS activity was elevated com pared with the non cirrhotic patients ( P 【0 01) In the splenic and gastri c coronary veins of cirrhotic patients, we found proliferative intima, extensive thrombi adhering to the venous wall, mimicked arteriosclerosis plaques accompan ied with hypertrophy of smooth muscle cells, and thickened muscle fibers of vein s with increase in extracelluar matrix Conclusion Portal hypertension may be complicated by splanchnic arterial and venous vasculo pathy There may be an interactive relationship among portal hypertension, spla nchnic hyperdynamic disturbances and splanchnic vasculopathy in the pathogenesis of portal hypertension展开更多
The fabrication technique of micro/nano-scale speckle patterns with focused ion beam (FIB) system is studied for digital image correlation (DIC) measurement under a scanning electron microscope (SEM).The speckle patte...The fabrication technique of micro/nano-scale speckle patterns with focused ion beam (FIB) system is studied for digital image correlation (DIC) measurement under a scanning electron microscope (SEM).The speckle patterns are fabricated by directly etching the counterpart of the specimen to the black part of a template.Mean intensity gradient is used to evaluate the quality of these SEM images of speckle patterns fabricated based on different templates to select an optimum template.The pattern size depending on the displacement measurement sensitivity is adjusted by altering the magnification of FIB according to the relation curve of the etching size versus magnification.The influencing factors including etching time and ion beam current are discussed.Rigid body translation tests and rotation tests are carried out under SEM to verify the reliability of the fabricated speckle patterns.The calculated values are in good agreement with the imposed ones.展开更多
基金This work is supported by the Program for Young Outstanding Scientists of Institute of Chemistry,Chinese Academy of Science,and Beijing National Laboratory for Molecular SciencesHong Gao and Li-chang Guan are also supported by the K.C.Wong Education Foundation.
文摘In this study,we report the design and simulation of an electrostatic ion lens system consisting of 22 round metal plates.The opening of the extractor plate is covered withmetal mesh,which is for shielding the interaction region of the lens system from the high DC voltages applied to all other plates than the repeller and extractor plates.The Simion simulation shows that both velocity-mapping and time focusing can be achieved simultaneously when appropriate voltages are applied to each of the plates.This makes the ion lens system be able to focus large ionic volumes in all three dimensions,which is an essential requirement for crossed ion-molecule scattering studies.A three-dimensional ion velocity measurement system with multi-hit and potential multi-mass capability is built,which consists of a microchannel plate(MCP),a P47 phosphor screen,a CMOS camera,a fast photomultiplier tube(PMT),and a high-speed digitizer.The two velocity components perpendicular to the flight axis are measured by the CMOS camera,and the time-of-flight,from which the velocity component along the flight axis can be deduced,is measured by the PMT.A Labview program is written to combine the two measurements for building the full three-dimensional ion velocity in real time on a frame-by-frame basis.The multi-hit capability comes from the fact that multiple ions from the camera and PMT in the same frame can be correlated with each other based on their various intensities.We demonstrate this by using the photodissociation of CH31 at 304 nm.
文摘OBJECTIVE: To investigate the characteristics of multifocal electroretinograms (mf-ERG) of different phases in diabetic retinopathy (DR) and its clinical significance. METHODS: Multifocal electroretinograms in patients with DR (I - II stage) were tested with VERIS IV system. RESULTS: In I - II stage, the absolute values of N1, P1 and N2 response densities, and the N1-P1 and P1-N2 response densities were attenuated is a field of about 45 degrees in diameter. CONCLUSION: As a new objective and quantitative examination for spatial visual function, multifocal electroretinograms may be valuable in the diagnosis of diabetic retinopathy.
文摘To investigate the characteristics of multifocal electroretinograms (mf ERG) o f different phases in diabetic retinopathy (DR) and its clinical significance Methods Multifocal electroretinograms in patients with DR (Ⅰ-Ⅱ stage) were tested with VERIS Ⅳ system Results In Ⅰ-Ⅱ stage, the absolute values of N1, P1 and N2 response densities, and the N1 P1 and P1 N2 response densities were attenuated is a field of about 45 deg rees in diameter Conclusion As a new ABSTRACT and quantitative examination for spatial visual function, mul tifocal electroretinograms may be valuable in the diagnosis of diabetic retinopa thy
基金theNationalNaturalScienceFoundationofChina (No 3 0 170 92 0 )
文摘To investigate the pathological morphology alteration of the splanchnic vascular wall in portal hypertensive patients Methods Splenic arteries, veins and gastric coronary veins from portal hypertensive pati ents (n=50) were removed during esophagogastric devascularization with splenecto my and were observed under optic and electron microscopes The expression of iN OS in the splenic artery wall was analysed with immunohistochemistry Results The internal elastic membrane and medial elastic fibers of the splenic artery wa ll were broken and degenerated Atrophy, apoptosis and phenotypic changes were seen in smooth muscle cells of splenic arteries Positive staining for iNOS was seen in the cytoplasm of smooth muscle cells and iNOS activity was elevated com pared with the non cirrhotic patients ( P 【0 01) In the splenic and gastri c coronary veins of cirrhotic patients, we found proliferative intima, extensive thrombi adhering to the venous wall, mimicked arteriosclerosis plaques accompan ied with hypertrophy of smooth muscle cells, and thickened muscle fibers of vein s with increase in extracelluar matrix Conclusion Portal hypertension may be complicated by splanchnic arterial and venous vasculo pathy There may be an interactive relationship among portal hypertension, spla nchnic hyperdynamic disturbances and splanchnic vasculopathy in the pathogenesis of portal hypertension
基金supported by the National Basic Research Program of China (Grant Nos.2010CB631005 and 2011CB606105)the National Natural Science Foundation of China (Grant Nos.90916010 and 11172151)the Specialized Research Fund for the Doctoral Program of Higher Education (Grant No. 20090002110048)
文摘The fabrication technique of micro/nano-scale speckle patterns with focused ion beam (FIB) system is studied for digital image correlation (DIC) measurement under a scanning electron microscope (SEM).The speckle patterns are fabricated by directly etching the counterpart of the specimen to the black part of a template.Mean intensity gradient is used to evaluate the quality of these SEM images of speckle patterns fabricated based on different templates to select an optimum template.The pattern size depending on the displacement measurement sensitivity is adjusted by altering the magnification of FIB according to the relation curve of the etching size versus magnification.The influencing factors including etching time and ion beam current are discussed.Rigid body translation tests and rotation tests are carried out under SEM to verify the reliability of the fabricated speckle patterns.The calculated values are in good agreement with the imposed ones.