A system of on-line contamination detecting in hydraulic oil based on silting principle is accomplished, where, metal filter membrane as detector, solenoid as active force to propel piston to blotter and gain differen...A system of on-line contamination detecting in hydraulic oil based on silting principle is accomplished, where, metal filter membrane as detector, solenoid as active force to propel piston to blotter and gain differential pressure, step motor drives the membrane to filtrate and counter-flush, LabVIEW as detecting software platform, oil's contamination detecting indirectly by gauging differential pressure. Based on theory analysis, accomplished is relation between contamination level and differential pressure, realizing polynomial curve fitting, and calibration experiment. Field experiment is simulated in the condition of experimental laboratory, has credible precision and real-time performance, which can popularize to the field of production.展开更多
Objective: To develop an on line system for the measurement of blood viscosity and hematocrit. The dynamic changes of the macrovascular blood volumes, microvascular blood volumes and the total blood volume were observ...Objective: To develop an on line system for the measurement of blood viscosity and hematocrit. The dynamic changes of the macrovascular blood volumes, microvascular blood volumes and the total blood volume were observed by means of calculating from the testing result. Methods: Applying traditional viscosity measurement principle and specific wavelength optic density measurement method, an on line system for the measurement of blood viscosity and hematocrit was developed, and the A/D multifunctional board and the testing circuit were designed by ourselves. The system was validated by experiments both in vitro and in vivo. Therapeutic effects of hypertonic saline dextran solution (HSD) and Lactatic Ringers solution at the early stage after burn blast combined injury were compared by this method. Results: The results showed that the system has attained the goal of the design. The changes of the blood viscosity and hematocrit could be detected effectively and continuously. The changes of macrovascular, microvascular and total blood volume could be calculated approximately. Conclusions: The system and the method can continuously on line test the blood viscosity and hematocrit, and reveal the change and distribution of blood volumes more accurately and clearly in the therapy process by estimatng changes of the macrovascular, microvascular and total blood volumes, respectively. It has confirmed that HSD treatment could increase blood pressure and attenuate tissue edema by significantly increasing total blood volume, improving macrocirculatory and microcirculatory blood volumes. This study suggested that it could be desirable to develop an experiment technique based on the method mentioned above.展开更多
Ca3Co409/Nb-SrTiO3 heterojunction with good rectifying behavior at room temperature was fabricated by growing a layer of Ca3Co409 film on the lwt% Nb-doped SrTiO3 substrate by means of the chemical solution deposition...Ca3Co409/Nb-SrTiO3 heterojunction with good rectifying behavior at room temperature was fabricated by growing a layer of Ca3Co409 film on the lwt% Nb-doped SrTiO3 substrate by means of the chemical solution deposition technique. A large open-circuit voltage signal with the response time of tens of nanosecond was observed at room temperature when the Ca3Co409 layer of the heterojunction was illuminated under the 308 nm irradiation and no voltage signal was detected under the 10.6 gun irradiation. A mechanism based on the photovoltaic effect of a p-n junction was proposed to explain the experimental results. The present work shows a great potential of this new heterojunction as photoelectric devices.展开更多
文摘A system of on-line contamination detecting in hydraulic oil based on silting principle is accomplished, where, metal filter membrane as detector, solenoid as active force to propel piston to blotter and gain differential pressure, step motor drives the membrane to filtrate and counter-flush, LabVIEW as detecting software platform, oil's contamination detecting indirectly by gauging differential pressure. Based on theory analysis, accomplished is relation between contamination level and differential pressure, realizing polynomial curve fitting, and calibration experiment. Field experiment is simulated in the condition of experimental laboratory, has credible precision and real-time performance, which can popularize to the field of production.
文摘Objective: To develop an on line system for the measurement of blood viscosity and hematocrit. The dynamic changes of the macrovascular blood volumes, microvascular blood volumes and the total blood volume were observed by means of calculating from the testing result. Methods: Applying traditional viscosity measurement principle and specific wavelength optic density measurement method, an on line system for the measurement of blood viscosity and hematocrit was developed, and the A/D multifunctional board and the testing circuit were designed by ourselves. The system was validated by experiments both in vitro and in vivo. Therapeutic effects of hypertonic saline dextran solution (HSD) and Lactatic Ringers solution at the early stage after burn blast combined injury were compared by this method. Results: The results showed that the system has attained the goal of the design. The changes of the blood viscosity and hematocrit could be detected effectively and continuously. The changes of macrovascular, microvascular and total blood volume could be calculated approximately. Conclusions: The system and the method can continuously on line test the blood viscosity and hematocrit, and reveal the change and distribution of blood volumes more accurately and clearly in the therapy process by estimatng changes of the macrovascular, microvascular and total blood volumes, respectively. It has confirmed that HSD treatment could increase blood pressure and attenuate tissue edema by significantly increasing total blood volume, improving macrocirculatory and microcirculatory blood volumes. This study suggested that it could be desirable to develop an experiment technique based on the method mentioned above.
基金supported by the National Natural Science Foundation of China (Grant No.10904030)the Key Project of Hebei Education Department (Grant No.ZD200909)
文摘Ca3Co409/Nb-SrTiO3 heterojunction with good rectifying behavior at room temperature was fabricated by growing a layer of Ca3Co409 film on the lwt% Nb-doped SrTiO3 substrate by means of the chemical solution deposition technique. A large open-circuit voltage signal with the response time of tens of nanosecond was observed at room temperature when the Ca3Co409 layer of the heterojunction was illuminated under the 308 nm irradiation and no voltage signal was detected under the 10.6 gun irradiation. A mechanism based on the photovoltaic effect of a p-n junction was proposed to explain the experimental results. The present work shows a great potential of this new heterojunction as photoelectric devices.