With more scaling, the speed of than 40 years Moore CMOS transistors is around 100 GHz. Such fact makes it possible to realize mm-wave circuits in CMOS. However, with the target of achieving broadband and power-effici...With more scaling, the speed of than 40 years Moore CMOS transistors is around 100 GHz. Such fact makes it possible to realize mm-wave circuits in CMOS. However, with the target of achieving broadband and power-efficient operation, 60 GHz CMOS RF transceiver faces severe challenges. After reviewing the technology issues, regarding the 60 GHz applications, this paper discusses design challenges both from the system and the building block levels, and also presents some simulated or measured circuits results.展开更多
The wave iterative method is a numerical method used in the electromagnetic modeling of high frequency electronic circuits. The object of the authors' study is to improve the convergence speed of this method by addin...The wave iterative method is a numerical method used in the electromagnetic modeling of high frequency electronic circuits. The object of the authors' study is to improve the convergence speed of this method by adding a new algorithm based on filtering techniques. This method requires a maximum number of iterations, noted Nmax, to achieve the convergence to the optimal value. This number wilt be reduced in order to reduce the computing time. The remaining iterations until Nmax will be calculated by the new algorithm which ensures a rapid convergence to the optimal result.展开更多
Betavoltaic radioisotope microbatteries have gradually become the research direction of micro-power sources because of their several advantages,including small scale,stable output performance,long service life,high en...Betavoltaic radioisotope microbatteries have gradually become the research direction of micro-power sources because of their several advantages,including small scale,stable output performance,long service life,high energy density,strong anti-jamming capability,and so on.Based on the theory of semiconductor physics,the current paper presented a design scheme of isotope microbattery with wide-gap semiconductor material GaN and isotope 147Pm.In consideration of the isotope's self-absorption effect,the current paper studied and analyzed the optimization thickness of semiconductor and isotope source,junction depth,depletion region thickness,doping concentration,and the generation and collection of electron hole pairs with simulation of transport process of beta particles in semiconductor material using Monte Carlo simulation program MCNP.In the proposed design scheme,for a single decay,an average energy of 28.2 keV was deposited in the GaN,and the short circuit current density,open circuit voltage,and efficiency of a single device were 1.636 μA/cm2,3.16 V,and 13.4%,respectively.展开更多
A magneto-optical sensor, using a dual quadrature polarimetfic processing scheme, was evaluated for current metering and protection applications in high voltage lines. Sensor calibration and resolution were obtained i...A magneto-optical sensor, using a dual quadrature polarimetfic processing scheme, was evaluated for current metering and protection applications in high voltage lines. Sensor calibration and resolution were obtained in different operational conditions using illumination in the 1550-nm band. Results obtained indicated the feasibility of interrogating such sensor via the optical ground wire (OPGW) link installed in standard high power grids. The polarimetric bulk optical current sensor also was theoretically studied, and the effects of different sources of error considering practical deployment were evaluated. In particular, the interference from external magnetic fields in a tree-phase system was analyzed.展开更多
Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers o...Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering application.To deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment method.Through the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the stator.The calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original model.Moreover,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault monitoring.Finally,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is depicted.The result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity.展开更多
基金the Project'Design of 60GHz RF CMOS chips and modules'supported by Chinese National High Tech.(863)Plan(2011AA010201 and 2011AA010202)partly supported by National Natural Science Foundation of China(No.61306030)
文摘With more scaling, the speed of than 40 years Moore CMOS transistors is around 100 GHz. Such fact makes it possible to realize mm-wave circuits in CMOS. However, with the target of achieving broadband and power-efficient operation, 60 GHz CMOS RF transceiver faces severe challenges. After reviewing the technology issues, regarding the 60 GHz applications, this paper discusses design challenges both from the system and the building block levels, and also presents some simulated or measured circuits results.
文摘The wave iterative method is a numerical method used in the electromagnetic modeling of high frequency electronic circuits. The object of the authors' study is to improve the convergence speed of this method by adding a new algorithm based on filtering techniques. This method requires a maximum number of iterations, noted Nmax, to achieve the convergence to the optimal value. This number wilt be reduced in order to reduce the computing time. The remaining iterations until Nmax will be calculated by the new algorithm which ensures a rapid convergence to the optimal result.
基金supported by the China Postdoctoral Science Foundation Funded Project (Grant No. 20100481140)the Nanjing University of Aeronautics and Astronautics Basic Research Funded Project (Grant No. Y1065-063)
文摘Betavoltaic radioisotope microbatteries have gradually become the research direction of micro-power sources because of their several advantages,including small scale,stable output performance,long service life,high energy density,strong anti-jamming capability,and so on.Based on the theory of semiconductor physics,the current paper presented a design scheme of isotope microbattery with wide-gap semiconductor material GaN and isotope 147Pm.In consideration of the isotope's self-absorption effect,the current paper studied and analyzed the optimization thickness of semiconductor and isotope source,junction depth,depletion region thickness,doping concentration,and the generation and collection of electron hole pairs with simulation of transport process of beta particles in semiconductor material using Monte Carlo simulation program MCNP.In the proposed design scheme,for a single decay,an average energy of 28.2 keV was deposited in the GaN,and the short circuit current density,open circuit voltage,and efficiency of a single device were 1.636 μA/cm2,3.16 V,and 13.4%,respectively.
文摘A magneto-optical sensor, using a dual quadrature polarimetfic processing scheme, was evaluated for current metering and protection applications in high voltage lines. Sensor calibration and resolution were obtained in different operational conditions using illumination in the 1550-nm band. Results obtained indicated the feasibility of interrogating such sensor via the optical ground wire (OPGW) link installed in standard high power grids. The polarimetric bulk optical current sensor also was theoretically studied, and the effects of different sources of error considering practical deployment were evaluated. In particular, the interference from external magnetic fields in a tree-phase system was analyzed.
基金supported by the National Natural Science Foundation of China (Grant No. 50807027)the China Postdoctoral Science Foundation(Grant No. 2012M520155)the Fundamental Research Funds for the Central Universities (Grant No. 2013JBM081)
文摘Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering application.To deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment method.Through the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the stator.The calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original model.Moreover,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault monitoring.Finally,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is depicted.The result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity.