This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ...This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.展开更多
The increased level of penetration of wind generators into modern power system has significant effect on network operation. The time varying nature of wind speed has significant effect on performance of wind generator...The increased level of penetration of wind generators into modern power system has significant effect on network operation. The time varying nature of wind speed has significant effect on performance of wind generator, therefore efficient mechanism for stabilizing the output of the wind generator is very much needed. Self-excited induction generators (SEIG) already existing in the network are sensitive to wind speeds. In this paper, a new method for voltage control of SEIG utilizing reactive power enhancing capabilities of doubly-fed induction generator (DFIG) is simulated and its effect on the network is analyzed for varying wind speeds. The choice of placing DFIG adjacent to SEIG or at another bus is also addressed in this paper with simulation results. The results show that this method of utilizing the reactive power capabilities of DFIG enhances voltage stability of SEIG as well as system stability.展开更多
基金Project (No. 50577056) supported by the National Natural ScienceFoundation of China
文摘This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.
文摘The increased level of penetration of wind generators into modern power system has significant effect on network operation. The time varying nature of wind speed has significant effect on performance of wind generator, therefore efficient mechanism for stabilizing the output of the wind generator is very much needed. Self-excited induction generators (SEIG) already existing in the network are sensitive to wind speeds. In this paper, a new method for voltage control of SEIG utilizing reactive power enhancing capabilities of doubly-fed induction generator (DFIG) is simulated and its effect on the network is analyzed for varying wind speeds. The choice of placing DFIG adjacent to SEIG or at another bus is also addressed in this paper with simulation results. The results show that this method of utilizing the reactive power capabilities of DFIG enhances voltage stability of SEIG as well as system stability.