Using the variable transformation method,the formulae of the axial symmetrical wall temperature distribution during steady heat conduction of a hollow cylinder are derived in this paper.The wall temperature distributi...Using the variable transformation method,the formulae of the axial symmetrical wall temperature distribution during steady heat conduction of a hollow cylinder are derived in this paper.The wall temperature distribution and the wall heat flux distribution in both axial and radial direction can be calculated by the temperature distribution of the liquid medium both inside and outside the cylinder with temperature changing in axial direction.The calculation results are almost consistent with the experience results.The applicative condition of the formulae in this paper consists with most of practice.They can be applied to the engineering calculation of the steady heat conduction.The calculation is simple and accurate.展开更多
The multi-piped freezing method is usually applied in artificial ground freezing (AGF) projects to fulfill special construction requirements, such as two-, three-, or four-piped freezing. Based on potential superpos...The multi-piped freezing method is usually applied in artificial ground freezing (AGF) projects to fulfill special construction requirements, such as two-, three-, or four-piped freezing. Based on potential superposition theory, this paper gives analytical solutions to steady-state frozen temperature for two, three, and four freezing pipes with different temperatures and arranged at random. Specific solutions are derived for some particular arrangements, such as three freezing pipes in a linear arrangement with equal or unequal spacing, right and isosceles triangle arrangements, four freezing pipes in a linear arrangement with equal spacing, and rhombus and rectangle arrangements. A comparison between the analytical solutions and numerical thermal analysis shows that the analytical solutions are sufficiently precise. As a part of the theory of AGF, the analytical solutions of temperature fields for multi-piped freezing with arbitrary layouts and different temperatures of freezing pipes are approached for the first time.展开更多
文摘Using the variable transformation method,the formulae of the axial symmetrical wall temperature distribution during steady heat conduction of a hollow cylinder are derived in this paper.The wall temperature distribution and the wall heat flux distribution in both axial and radial direction can be calculated by the temperature distribution of the liquid medium both inside and outside the cylinder with temperature changing in axial direction.The calculation results are almost consistent with the experience results.The applicative condition of the formulae in this paper consists with most of practice.They can be applied to the engineering calculation of the steady heat conduction.The calculation is simple and accurate.
基金Project supported by the National Natural Science Foundation of China (Nos. 51178336 and 51478340), the Natural Science Foundation of Zhejiang Province, China (No. LZ13E080002), and the China Ministry of Communications Construction Science & Technology Projects (No. 2013318R11300)
文摘The multi-piped freezing method is usually applied in artificial ground freezing (AGF) projects to fulfill special construction requirements, such as two-, three-, or four-piped freezing. Based on potential superposition theory, this paper gives analytical solutions to steady-state frozen temperature for two, three, and four freezing pipes with different temperatures and arranged at random. Specific solutions are derived for some particular arrangements, such as three freezing pipes in a linear arrangement with equal or unequal spacing, right and isosceles triangle arrangements, four freezing pipes in a linear arrangement with equal spacing, and rhombus and rectangle arrangements. A comparison between the analytical solutions and numerical thermal analysis shows that the analytical solutions are sufficiently precise. As a part of the theory of AGF, the analytical solutions of temperature fields for multi-piped freezing with arbitrary layouts and different temperatures of freezing pipes are approached for the first time.