Objective To explore the effects of sliding-cup with different parameters on energy metabolism in the body by observing the effect of sliding-cup along the governor vessel on transcutaneous partial pressures of oxygen...Objective To explore the effects of sliding-cup with different parameters on energy metabolism in the body by observing the effect of sliding-cup along the governor vessel on transcutaneous partial pressures of oxygen and carbon dioxide in Mìngmén(命门 GV 4) in sub-healthy people. Methods A total of 10 sub-healthy adults at rest were observed and sliding-cup along the governor vessel were conducted with three different parameters, jar-pressure of –0.01~ –0.02 MPa with sliding-cup for 5 min, jar-pressure of –0.02~ –0.03 MPa with sliding-cup for 5 min and jar-pressure of –0.02~ –0.03 MPa with slidingcup for 3 min. Peri Flux System5000 PF5040 module was employed to monitor the changes of transcutaneous partial pressures of oxygen(tcp O2) and carbon dioxide(tcp CO2) in GV 4 at 0 min, 5 min, 10 min, 15 min, 20 min, 25 min and 30 min after sliding-cup with above different interventions in sub-healthy subjects. Results After sliding-cup, tcp O2 increased at first and then decreased over time; there was no difference in tcp O2 after sliding-cupping with different parameters(all P0.05). After sliding-cup, tcp CO2 decreased; there was no difference in tcp CO2 after sliding-cup with different parameters(all P0.05). Conclusion Sliding-cup has a sustained effect on the body and can speed up the energy metabolism in the body.展开更多
基金Suported by Tianjin Municipal Administration of Traditional Chinese Medicine:11028
文摘Objective To explore the effects of sliding-cup with different parameters on energy metabolism in the body by observing the effect of sliding-cup along the governor vessel on transcutaneous partial pressures of oxygen and carbon dioxide in Mìngmén(命门 GV 4) in sub-healthy people. Methods A total of 10 sub-healthy adults at rest were observed and sliding-cup along the governor vessel were conducted with three different parameters, jar-pressure of –0.01~ –0.02 MPa with sliding-cup for 5 min, jar-pressure of –0.02~ –0.03 MPa with sliding-cup for 5 min and jar-pressure of –0.02~ –0.03 MPa with slidingcup for 3 min. Peri Flux System5000 PF5040 module was employed to monitor the changes of transcutaneous partial pressures of oxygen(tcp O2) and carbon dioxide(tcp CO2) in GV 4 at 0 min, 5 min, 10 min, 15 min, 20 min, 25 min and 30 min after sliding-cup with above different interventions in sub-healthy subjects. Results After sliding-cup, tcp O2 increased at first and then decreased over time; there was no difference in tcp O2 after sliding-cupping with different parameters(all P0.05). After sliding-cup, tcp CO2 decreased; there was no difference in tcp CO2 after sliding-cup with different parameters(all P0.05). Conclusion Sliding-cup has a sustained effect on the body and can speed up the energy metabolism in the body.