Sustainable building design in dry tropical areas recommends reducing exposure of buildings to solar radiation and/or designing efficient enclosures with satisfactory thermal inertia.We propose in this paper a study o...Sustainable building design in dry tropical areas recommends reducing exposure of buildings to solar radiation and/or designing efficient enclosures with satisfactory thermal inertia.We propose in this paper a study of the influence of the infiltration rate in the building and the coefficient of thermal transfer by convection of the walls, on the thermal comfort using TRNSYS software. All the models carried out were validated by recognized scientific criteria, namely correlation (R) and determination (R2) coefficients on the one hand and NBME and CVRMSE coefficients defined by ASHARE, 2002 on the other hand. The results obtained indicate that the modulation of the air infiltration rate allows the simulations on TRNSYS to be compared to in-situ measurements, with an annual average relative difference of 2.86% on the temperature difference. Furthermore, depending on the parameterization of the heat transfer coefficients by convection of the internal and external walls of walls used in the STD, the average annual difference can be reduced by 1% to 4% between the predictions and the measurements.展开更多
Building equipment, energy-saving systems, and claims of inappropriate indoor thermal environments were analyzed in relation to the floor area using responses to a questionnaire survey of service managers of 157 build...Building equipment, energy-saving systems, and claims of inappropriate indoor thermal environments were analyzed in relation to the floor area using responses to a questionnaire survey of service managers of 157 buildings built in Osaka, Kyoto and Hyogo prefectures in Kinki area of Japan. Results show the following: (1) In smaller buildings (〈 5,000 m2), setting temperatures are higher in summer and lower in winter, effects of "uncomfortable radiation from windows" are greater, energy-saving systems decrease indoor thermal comfort, but claims of "hot" and "cold" are fewer; (2) Claims of "hot" and "cold" are unrelated to the setting temperature and whether the air-conditioning control system is central or local; (3) The adoption rates of mitigation of dress codes ("COOL-BIZ" and "WARM-BIZ") are higher than those of temperature mitigation of air conditioning.展开更多
Analyzing the effects of heat rejection from condensers of split-type air-conditioning units at lower-floors of MLABs (multi-level apartment buildings), using field measurements to monitor environmental conditions a...Analyzing the effects of heat rejection from condensers of split-type air-conditioning units at lower-floors of MLABs (multi-level apartment buildings), using field measurements to monitor environmental conditions and condenser operation, revealed increases in the inlet air temperature at the condensers at the upper floors, which in turn increased the power and energy requirements for these units and decreased their cooling capacities. Results indicated that a decrease of up to 16,000 tons in cooling capacity and an increase of up to 67.2 MW in the national peak load demand might be reached for a 4 ℃ temperature differential for Kuwait conditions. It is recommended that the condensers be placed in the wind pathway to minimize the impact of heat rejection and stack effect and to optimize the operation of split-type air-conditioning units, and that other factors regarding installation setup and location are investigated.展开更多
文摘Sustainable building design in dry tropical areas recommends reducing exposure of buildings to solar radiation and/or designing efficient enclosures with satisfactory thermal inertia.We propose in this paper a study of the influence of the infiltration rate in the building and the coefficient of thermal transfer by convection of the walls, on the thermal comfort using TRNSYS software. All the models carried out were validated by recognized scientific criteria, namely correlation (R) and determination (R2) coefficients on the one hand and NBME and CVRMSE coefficients defined by ASHARE, 2002 on the other hand. The results obtained indicate that the modulation of the air infiltration rate allows the simulations on TRNSYS to be compared to in-situ measurements, with an annual average relative difference of 2.86% on the temperature difference. Furthermore, depending on the parameterization of the heat transfer coefficients by convection of the internal and external walls of walls used in the STD, the average annual difference can be reduced by 1% to 4% between the predictions and the measurements.
文摘Building equipment, energy-saving systems, and claims of inappropriate indoor thermal environments were analyzed in relation to the floor area using responses to a questionnaire survey of service managers of 157 buildings built in Osaka, Kyoto and Hyogo prefectures in Kinki area of Japan. Results show the following: (1) In smaller buildings (〈 5,000 m2), setting temperatures are higher in summer and lower in winter, effects of "uncomfortable radiation from windows" are greater, energy-saving systems decrease indoor thermal comfort, but claims of "hot" and "cold" are fewer; (2) Claims of "hot" and "cold" are unrelated to the setting temperature and whether the air-conditioning control system is central or local; (3) The adoption rates of mitigation of dress codes ("COOL-BIZ" and "WARM-BIZ") are higher than those of temperature mitigation of air conditioning.
文摘Analyzing the effects of heat rejection from condensers of split-type air-conditioning units at lower-floors of MLABs (multi-level apartment buildings), using field measurements to monitor environmental conditions and condenser operation, revealed increases in the inlet air temperature at the condensers at the upper floors, which in turn increased the power and energy requirements for these units and decreased their cooling capacities. Results indicated that a decrease of up to 16,000 tons in cooling capacity and an increase of up to 67.2 MW in the national peak load demand might be reached for a 4 ℃ temperature differential for Kuwait conditions. It is recommended that the condensers be placed in the wind pathway to minimize the impact of heat rejection and stack effect and to optimize the operation of split-type air-conditioning units, and that other factors regarding installation setup and location are investigated.