A rack cooling system based on a large scale flat plate pulsating heat pipe is proposed. The heat generated from IT equipment in a closed rack is transferred by the rear door pulsating heat pipe to the chilled air pas...A rack cooling system based on a large scale flat plate pulsating heat pipe is proposed. The heat generated from IT equipment in a closed rack is transferred by the rear door pulsating heat pipe to the chilled air passage and is avoided to release into the room. The influence of the start-up performance of the heat pipe, the load of the rack and the load dissipation to the temperature and the velocity distribution in the rack are discussed. It is found that the temperature would be lower and the temperature distribution would be more uniform in the rack when the pulsating heat pipe is in operation. Also, the effect of rack electricity load on temperature distribution is analyzed. It is indicated that higher velocity of chilled air will improve heat transfer of the rack.展开更多
This paper deals with experimental study of flow field of starting process in two-dimensional, single-stage supersonic ejector on different air total pressure. Schlieren pictures of flow field were taken, static press...This paper deals with experimental study of flow field of starting process in two-dimensional, single-stage supersonic ejector on different air total pressure. Schlieren pictures of flow field were taken, static pressure distribu-tions on side wall were measured. The obtained results show that, on critical pressure, the starting main shock waves in ejector oscillated back and forth between the second throat and the middle section of the mixing chamber, it causes the pressure in the second half of the mixing chamber acutely fluctuated .When the working pressure of the active flow is higher than the critical starting pressure, ejector starts normally and the inner flow-field of the mixing chamber keeps stable and the shock waves in the second throat have a certain degree of oscillation . After ejector starts, the operating pressure of the active flow may be lower than the starting pressure .展开更多
基金supported by National Natural Science Foundation of China(No.51376019)
文摘A rack cooling system based on a large scale flat plate pulsating heat pipe is proposed. The heat generated from IT equipment in a closed rack is transferred by the rear door pulsating heat pipe to the chilled air passage and is avoided to release into the room. The influence of the start-up performance of the heat pipe, the load of the rack and the load dissipation to the temperature and the velocity distribution in the rack are discussed. It is found that the temperature would be lower and the temperature distribution would be more uniform in the rack when the pulsating heat pipe is in operation. Also, the effect of rack electricity load on temperature distribution is analyzed. It is indicated that higher velocity of chilled air will improve heat transfer of the rack.
文摘This paper deals with experimental study of flow field of starting process in two-dimensional, single-stage supersonic ejector on different air total pressure. Schlieren pictures of flow field were taken, static pressure distribu-tions on side wall were measured. The obtained results show that, on critical pressure, the starting main shock waves in ejector oscillated back and forth between the second throat and the middle section of the mixing chamber, it causes the pressure in the second half of the mixing chamber acutely fluctuated .When the working pressure of the active flow is higher than the critical starting pressure, ejector starts normally and the inner flow-field of the mixing chamber keeps stable and the shock waves in the second throat have a certain degree of oscillation . After ejector starts, the operating pressure of the active flow may be lower than the starting pressure .