期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
环已烷空气氧化系统采用安全连锁保护措施
1
作者 李德林 《化工劳动保护(安全技术与管理分册)》 1990年第4期35-36,共2页
关键词 环己烷 空气氧化系统 安全连锁保护
下载PDF
System design and analysis of the trans-critical carbon-dioxide automotive air-conditioning system 被引量:2
2
作者 穆景阳 陈江平 陈芝久 《Journal of Zhejiang University Science》 EI CSCD 2003年第3期305-308,共4页
As an environmentally harmless and feasible alternate refrigerant, CO 2 has attracted worldwide attention, especially in the area of automobile air conditioning (AAC). The thermal property of CO 2 and its trans cr... As an environmentally harmless and feasible alternate refrigerant, CO 2 has attracted worldwide attention, especially in the area of automobile air conditioning (AAC). The thermal property of CO 2 and its trans critical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO 2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO 2 AAC system. 展开更多
关键词 Automotive air conditioning(AAC) Carbon dioxide Trans critical cycle.
下载PDF
Experimental Study of a Photocatalytic Reactor for Trace Formaldehyde Removal
3
作者 刘红敏 连之伟 +1 位作者 叶晓江 上官文峰 《Journal of Donghua University(English Edition)》 EI CAS 2005年第3期111-115,共5页
Formaldehyde is the key contaminant influencing building occupants' health in indoor environment. In order to reduce occupants' exposures to formaldehyde, a newly designed photocatalytic reactor was applied in a dyn... Formaldehyde is the key contaminant influencing building occupants' health in indoor environment. In order to reduce occupants' exposures to formaldehyde, a newly designed photocatalytic reactor was applied in a dynamic HVAC (heating, ventilation and air conditioning) system. The experiments were carried out for the removal of formaldehyde present in air at low parts per million (ppm) concentrations. The initial formaldehyde concentrations were set as 1.59 ppm and 0.27 ppm respectively, based on the formaldehyde levels in the polluted places. Experimental results show that the photocatalytic reactor is effective on formaldehyde photodegradation, causes a low pressure drop, and does not make the second pollution of ozone. The kinetic anaiysis indicates that the kinetics for oxidation processes can be fitted well by a pseudo-first-order kinetic model deduced from Langmuir - Hinshelwood (L-H) model. 展开更多
关键词 FORMALDEHYDE titanium dioxide photocatalytic reactor air-conditioning system
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
4
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
上一页 1 下一页 到第