The production and utilization of high-energetic explosives often pose a range of safety hazards,with sensitivity being a key factor in evaluating these risks.To investigate how temperature,particle size,and air humid...The production and utilization of high-energetic explosives often pose a range of safety hazards,with sensitivity being a key factor in evaluating these risks.To investigate how temperature,particle size,and air humidity affect the responsiveness of commonly used high-energetic explosives,a series of BAM(Bundesanstalt für Materialforschung und-prüfung)impact and friction sensitivity tests were carried out to determine the critical impact energy and critical load pressure of four representative high-energetic explosives(RDX,HMX,PETN and CL-20)under different temperatures,particle sizes,and air humidity conditions.The experimental findings facilitated an examination of temperature and particle size affecting the sensitivity of high-energetic explosives,along with an assessment of the influence of air humidity on sensitivity testing.The results clearly indicate that high-energetic explosives display a substantial decline in critical reaction energy when subjected to micrometre-sized particles and an air humidity level of 45%at a temperature of 90℃.Furthermore,it was noted that the critical reaction energy of high-energetic explosives diminishes with an increase in temperature within 25℃−90℃.In the same vein,as the particle sizes of high-energetic explosives increase,so does the critical reaction energy for micrometre-sized particles.High air humidity significantly affects the sensitivity testing of high-energetic explosives,emphasizing the importance of refraining from conducting sensitivity tests in such conditions.展开更多
The results from three methods aimed at improving precipitation type (e.g., rain, sleet, and snow) estimation are presented and compared in this paper. The methods include the threshold air temperature (AT), thres...The results from three methods aimed at improving precipitation type (e.g., rain, sleet, and snow) estimation are presented and compared in this paper. The methods include the threshold air temperature (AT), threshold wet bulb temperature (WBT) and Koistinen and Saltikoff (KSS) methods. Dot graphs are plotted to acquire the threshold air temperature or the threshold wet bulb temperature using daily averaged air temperature, wet bulb temperature and precipitation data at 643 stations from 1961 to 1979 (precipitation types are not labeled in the database from 1980 to present) in China. The results indicate that the threshold AT or WBT methods are not able to differentiate rain, sleet and snow in the most regions in China; sleet is difficult to differentiate from other precipitation types based on the two threshold methods. Therefore, one threshold AT and WBT method was used in this study to differentiate rain and snow. Based on Gaussian- Kriging interpolation of threshold air temperature (To) and wet bulb temperature (Tw), the To and Tw contour lines and contour surfaces are calculated for China. Finally, a comparison between the KSS, AT and WBT methods are provided in which the KSS method is calculated based on air temperature and relative humidity. The results suggest that the KSS method is more appropriate for water phase estimation than are the other methods; the maximum precision for rain and snow is 99% and 94%, respectively. The AT method performs better than the WBT method when the critical air temperature is 2℃.展开更多
With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that ther...With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration.展开更多
In order to reveal transpiration rates of wetland plants and its relationships to micro-meterological factors in a mountain valley wetland, relative humidity, air temperature, leaf temperature, soil temperature, photo...In order to reveal transpiration rates of wetland plants and its relationships to micro-meterological factors in a mountain valley wetland, relative humidity, air temperature, leaf temperature, soil temperature, photo flux density and transpiration rates were measured once two hours in a Carex meyeriana wetland of the Changbai Mountain valley in dry (July) and wet (September) of 2003, respectively. Results showed that the tendency of "decreasing after increasing" was obvious in wet season. However, a relatively stable trend was observed for the transpiration in dry season.. Generally, the photon flux density of Carex meyeriana was higher in wet season than that in dry season. However, the variabilities of leaf temperature, air temperature and relative humidity were similar in both seasons. Higher transpiration rates of Carex meyeriana leaves were observed in July (varied from 40 to 150 mol·m-2·s-1) compared to those (varied from 7 to 14 mol·m-2·s-1) in September. Transpiration rates were significantly correlated with air temperature (P<0.01), leaf temperature (P<0.01), and wind speed (P<0.05), but correlationship between relative humidity and photo flux density was not significant (P<0.05).展开更多
Latvian children under the age of 7 can spend up to 60 hours per week in daycare centers and therefore it is very important to establish a healthy and comfortable daycare environment that children will find pleasant a...Latvian children under the age of 7 can spend up to 60 hours per week in daycare centers and therefore it is very important to establish a healthy and comfortable daycare environment that children will find pleasant and stimulating to stay in. This study investigates indoor air quality and thermal comfort within six daycare centers (old, renovated and new-built) in moderate climate zone of Latvia. Measurements of carbon dioxide, air temperature and relative humidity were carried out, and data regarding daycare center characteristics and maintenance activities was collected via combination of field visits, record analysis and interviews. It was found that carbon dioxide concentrations exceeded 1000 ppm in 75% of daycare centers studied, with the highest (1356 ppm) measured in a renovated facility with the natural ventilation system. Thus installation of more efficient ventilation system (mechanical) is recommended to provide acceptable indoor air quality, since opening of windows itself cannot provide the optimal conditions indoors. In all facilities the temperature was kept above 20℃ and the average relative humidity was 40±35%, creating comfortable thermal environment for children.展开更多
This study investigates the microclimatic connections between underground systems and the hibernation sites of particular species of bats. The distribution of hibernating bats was analysed in five selected zones desig...This study investigates the microclimatic connections between underground systems and the hibernation sites of particular species of bats. The distribution of hibernating bats was analysed in five selected zones designated Ⅰ-Ⅴ. These zones have a similar relative humidity, diverse temperature ranges inside the system, as well as air flow rates. A multi-year research programme highlighted the relationships between the occurrence of hibernating bats of various species and the microclimate of these particular zones. What is of essential importance are the sites with an air flow in their zones exceeding 0.02 m·s^-1, then is temperature and humidity. The air flow determines more intensive settling of wintering bats (zones Ⅲ, Ⅳand Ⅴ). The zone Ⅱ-tourist zone with periodic air flows and often visited by humans is the least used by hibernating bats.展开更多
基金supported by National Natural Science Foundation of China(No.12272184).
文摘The production and utilization of high-energetic explosives often pose a range of safety hazards,with sensitivity being a key factor in evaluating these risks.To investigate how temperature,particle size,and air humidity affect the responsiveness of commonly used high-energetic explosives,a series of BAM(Bundesanstalt für Materialforschung und-prüfung)impact and friction sensitivity tests were carried out to determine the critical impact energy and critical load pressure of four representative high-energetic explosives(RDX,HMX,PETN and CL-20)under different temperatures,particle sizes,and air humidity conditions.The experimental findings facilitated an examination of temperature and particle size affecting the sensitivity of high-energetic explosives,along with an assessment of the influence of air humidity on sensitivity testing.The results clearly indicate that high-energetic explosives display a substantial decline in critical reaction energy when subjected to micrometre-sized particles and an air humidity level of 45%at a temperature of 90℃.Furthermore,it was noted that the critical reaction energy of high-energetic explosives diminishes with an increase in temperature within 25℃−90℃.In the same vein,as the particle sizes of high-energetic explosives increase,so does the critical reaction energy for micrometre-sized particles.High air humidity significantly affects the sensitivity testing of high-energetic explosives,emphasizing the importance of refraining from conducting sensitivity tests in such conditions.
基金supported by National asic Research Program of China (Grant Nos. 013CBA01806)National Natural Sciences oundation of China (Grant Nos. 91025011, 1222001)
文摘The results from three methods aimed at improving precipitation type (e.g., rain, sleet, and snow) estimation are presented and compared in this paper. The methods include the threshold air temperature (AT), threshold wet bulb temperature (WBT) and Koistinen and Saltikoff (KSS) methods. Dot graphs are plotted to acquire the threshold air temperature or the threshold wet bulb temperature using daily averaged air temperature, wet bulb temperature and precipitation data at 643 stations from 1961 to 1979 (precipitation types are not labeled in the database from 1980 to present) in China. The results indicate that the threshold AT or WBT methods are not able to differentiate rain, sleet and snow in the most regions in China; sleet is difficult to differentiate from other precipitation types based on the two threshold methods. Therefore, one threshold AT and WBT method was used in this study to differentiate rain and snow. Based on Gaussian- Kriging interpolation of threshold air temperature (To) and wet bulb temperature (Tw), the To and Tw contour lines and contour surfaces are calculated for China. Finally, a comparison between the KSS, AT and WBT methods are provided in which the KSS method is calculated based on air temperature and relative humidity. The results suggest that the KSS method is more appropriate for water phase estimation than are the other methods; the maximum precision for rain and snow is 99% and 94%, respectively. The AT method performs better than the WBT method when the critical air temperature is 2℃.
文摘With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration.
基金supported by the National Basic Research Program of China (No.2006CB403301)the National Natural Science Foundation Project (4)the Emphasis Project Fund of National Eleventh Five-Year Scientific and Technical Support Plans (No.2006BAB04A08)
文摘In order to reveal transpiration rates of wetland plants and its relationships to micro-meterological factors in a mountain valley wetland, relative humidity, air temperature, leaf temperature, soil temperature, photo flux density and transpiration rates were measured once two hours in a Carex meyeriana wetland of the Changbai Mountain valley in dry (July) and wet (September) of 2003, respectively. Results showed that the tendency of "decreasing after increasing" was obvious in wet season. However, a relatively stable trend was observed for the transpiration in dry season.. Generally, the photon flux density of Carex meyeriana was higher in wet season than that in dry season. However, the variabilities of leaf temperature, air temperature and relative humidity were similar in both seasons. Higher transpiration rates of Carex meyeriana leaves were observed in July (varied from 40 to 150 mol·m-2·s-1) compared to those (varied from 7 to 14 mol·m-2·s-1) in September. Transpiration rates were significantly correlated with air temperature (P<0.01), leaf temperature (P<0.01), and wind speed (P<0.05), but correlationship between relative humidity and photo flux density was not significant (P<0.05).
文摘Latvian children under the age of 7 can spend up to 60 hours per week in daycare centers and therefore it is very important to establish a healthy and comfortable daycare environment that children will find pleasant and stimulating to stay in. This study investigates indoor air quality and thermal comfort within six daycare centers (old, renovated and new-built) in moderate climate zone of Latvia. Measurements of carbon dioxide, air temperature and relative humidity were carried out, and data regarding daycare center characteristics and maintenance activities was collected via combination of field visits, record analysis and interviews. It was found that carbon dioxide concentrations exceeded 1000 ppm in 75% of daycare centers studied, with the highest (1356 ppm) measured in a renovated facility with the natural ventilation system. Thus installation of more efficient ventilation system (mechanical) is recommended to provide acceptable indoor air quality, since opening of windows itself cannot provide the optimal conditions indoors. In all facilities the temperature was kept above 20℃ and the average relative humidity was 40±35%, creating comfortable thermal environment for children.
文摘This study investigates the microclimatic connections between underground systems and the hibernation sites of particular species of bats. The distribution of hibernating bats was analysed in five selected zones designated Ⅰ-Ⅴ. These zones have a similar relative humidity, diverse temperature ranges inside the system, as well as air flow rates. A multi-year research programme highlighted the relationships between the occurrence of hibernating bats of various species and the microclimate of these particular zones. What is of essential importance are the sites with an air flow in their zones exceeding 0.02 m·s^-1, then is temperature and humidity. The air flow determines more intensive settling of wintering bats (zones Ⅲ, Ⅳand Ⅴ). The zone Ⅱ-tourist zone with periodic air flows and often visited by humans is the least used by hibernating bats.