The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviou...The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviour of dairy cows in a farm located in Po Plain (Italy). The barn was provided with an air-water cooling system, based on the use of fans and sprinklers placed only in the feeding alley. Two different trials were carried out. The first experiment was targeted on verifying the use of the cubicles by the cows in relation to the availability of the cooling system only in feeding area. The second trial aimed at testing the effectiveness of zone cooling systems placed in the front of cubicles. For this purpose three cubicles in the barn were provided with cooling systems, based on the input of high velocity conditioned air streams. The results clearly remark that the behaviour of the animals is greatly influenced by the environmental conditions. With high temperatures the use of the cubicles is deeply reduced and the animals prefer to stay in feeding area, thus benefiting from the cooling effect of water sprinkled by the showers and of the air streams created by the fans. With air temperatures increasing from 21℃ to 33 ℃ the cows reduce the staying in the cubicles, which gets down from 540 to 32% (r2 = 0.2608). As regards the efficacy of zone cooling system in the cubicles, the results are not particularly encouraging. The cows continue to use the cubicles without changing the behaviour in relation to the presence of conditioned air flow.展开更多
In this work an economical evaluation that established the viability of a low enthalpy geothermal resource as an energy source in north Africa is presented. The factors considered included the payback period, average ...In this work an economical evaluation that established the viability of a low enthalpy geothermal resource as an energy source in north Africa is presented. The factors considered included the payback period, average rate of return, net present value, and net benefit-cost ratio. The model was based on utilising the energy source to energise four models that comprised thermal equipment consisting of water/air cooled single/half effect lithium bromide water mixture absorption chillers and an R-245fa organic Rankine cycle. These modelled cycles were based on the energy demand for Waddan city a community in southern Libya which has a demand for combined cooling/electricity only or cooling/electricity with district hot water supply. The results revealed that all of the proposed simulated stand-alone models, except the water-cooled half effect chiller, are not economically viable unless they are heavily subsidized or combined with the district hot water supply at least in the winter season.展开更多
An experiment was carried out to investigate the relation of the maximum velocity of air passing through narrowest passage, mass flux of spray water in one square meter in one hour and the pressure drop of tube bundle...An experiment was carried out to investigate the relation of the maximum velocity of air passing through narrowest passage, mass flux of spray water in one square meter in one hour and the pressure drop of tube bundles. Twelve equations were obtained for the relation. The results show that the pressure drop of the tube bundles increases with increase of the maximum velocity of air and the mass flux of spray water. Comparing the pressure drop of the bare tube bundles with that of the film-enhanced tube bundles, it is found that the pressure drop of the film-enhanced tube bundles is lower about 11% and the surface roughness of the film-enhanced plates is a main factor that influences the pressure drop. The data and method obtained in the paper can be used to compute the pressure drop of the film-enhanced tube bundles and is helpful for selection of fan.展开更多
文摘The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviour of dairy cows in a farm located in Po Plain (Italy). The barn was provided with an air-water cooling system, based on the use of fans and sprinklers placed only in the feeding alley. Two different trials were carried out. The first experiment was targeted on verifying the use of the cubicles by the cows in relation to the availability of the cooling system only in feeding area. The second trial aimed at testing the effectiveness of zone cooling systems placed in the front of cubicles. For this purpose three cubicles in the barn were provided with cooling systems, based on the input of high velocity conditioned air streams. The results clearly remark that the behaviour of the animals is greatly influenced by the environmental conditions. With high temperatures the use of the cubicles is deeply reduced and the animals prefer to stay in feeding area, thus benefiting from the cooling effect of water sprinkled by the showers and of the air streams created by the fans. With air temperatures increasing from 21℃ to 33 ℃ the cows reduce the staying in the cubicles, which gets down from 540 to 32% (r2 = 0.2608). As regards the efficacy of zone cooling system in the cubicles, the results are not particularly encouraging. The cows continue to use the cubicles without changing the behaviour in relation to the presence of conditioned air flow.
文摘In this work an economical evaluation that established the viability of a low enthalpy geothermal resource as an energy source in north Africa is presented. The factors considered included the payback period, average rate of return, net present value, and net benefit-cost ratio. The model was based on utilising the energy source to energise four models that comprised thermal equipment consisting of water/air cooled single/half effect lithium bromide water mixture absorption chillers and an R-245fa organic Rankine cycle. These modelled cycles were based on the energy demand for Waddan city a community in southern Libya which has a demand for combined cooling/electricity only or cooling/electricity with district hot water supply. The results revealed that all of the proposed simulated stand-alone models, except the water-cooled half effect chiller, are not economically viable unless they are heavily subsidized or combined with the district hot water supply at least in the winter season.
基金Acknowledgement: The study is supported by the National Nature Science Foundation. Patent code is 200620098211.4.
文摘An experiment was carried out to investigate the relation of the maximum velocity of air passing through narrowest passage, mass flux of spray water in one square meter in one hour and the pressure drop of tube bundles. Twelve equations were obtained for the relation. The results show that the pressure drop of the tube bundles increases with increase of the maximum velocity of air and the mass flux of spray water. Comparing the pressure drop of the bare tube bundles with that of the film-enhanced tube bundles, it is found that the pressure drop of the film-enhanced tube bundles is lower about 11% and the surface roughness of the film-enhanced plates is a main factor that influences the pressure drop. The data and method obtained in the paper can be used to compute the pressure drop of the film-enhanced tube bundles and is helpful for selection of fan.