The cooling and heating load distribution of large area air-conditioned room such as “open” offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is n...The cooling and heating load distribution of large area air-conditioned room such as “open” offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is not the case in reality, and a low efficient air conditioning system results from this assumption. A simulation and analysis of the cooling load distribution of an office building in Hong Kong with TRANSYS software is provided in this paper. A typical office is divided into 13 zones for simulation, including external zone, medial zone and internal zone in the north, the south, the east and the west respectively and a central zone, instead of 4 directional zone. The result shows there is much cooling load difference between each zone, and more attention should be paid to uneven indoor cooling and heating load distribution to further guide the design.展开更多
Geothermal is a fast-growing alternative heat source for HVAC systems, however, the initial cost of using a ground source HVAC system is higher compared to an air source system. Studies about system design and operati...Geothermal is a fast-growing alternative heat source for HVAC systems, however, the initial cost of using a ground source HVAC system is higher compared to an air source system. Studies about system design and operation are necessary to reduce the initial cost and ensure that the ground source heat pump system has high efficiency, resulting in a lower total life-time cost. In this study, a multi-variable evolutionary computation algorithm is proposed for generating optimal parameters for a geothermal source HVAC system. The system was modeled and simulated using MATLAB. The design parameters were calculated by minimizing the energy consumption, Based on an experimental building, a case study was presented. Using this model, the optimal set points were calculated and used as a designed system. Energy consumption of this system was reduced by about 10% compared to the system operated with a fixed supply cold water temperature (7 ℃).展开更多
文摘The cooling and heating load distribution of large area air-conditioned room such as “open” offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is not the case in reality, and a low efficient air conditioning system results from this assumption. A simulation and analysis of the cooling load distribution of an office building in Hong Kong with TRANSYS software is provided in this paper. A typical office is divided into 13 zones for simulation, including external zone, medial zone and internal zone in the north, the south, the east and the west respectively and a central zone, instead of 4 directional zone. The result shows there is much cooling load difference between each zone, and more attention should be paid to uneven indoor cooling and heating load distribution to further guide the design.
文摘Geothermal is a fast-growing alternative heat source for HVAC systems, however, the initial cost of using a ground source HVAC system is higher compared to an air source system. Studies about system design and operation are necessary to reduce the initial cost and ensure that the ground source heat pump system has high efficiency, resulting in a lower total life-time cost. In this study, a multi-variable evolutionary computation algorithm is proposed for generating optimal parameters for a geothermal source HVAC system. The system was modeled and simulated using MATLAB. The design parameters were calculated by minimizing the energy consumption, Based on an experimental building, a case study was presented. Using this model, the optimal set points were calculated and used as a designed system. Energy consumption of this system was reduced by about 10% compared to the system operated with a fixed supply cold water temperature (7 ℃).