Image interpolation of cross-sections is one of the key steps of medical visualization, and the cubic convolution interpolation is usually employed due to its good tradeoff between computational cost and accuracy, how...Image interpolation of cross-sections is one of the key steps of medical visualization, and the cubic convolution interpolation is usually employed due to its good tradeoff between computational cost and accuracy, however, sometimes its accuracy can still not meet the requirement. Aimed at the problem, in this paper, the interpolation principle based cubic convolution is firstly analyzed systematically, and then essential relationship among the different cubic convolution interpolation methods is clarified. Lastly, a novel cross-section interpolation method for medical images that is based on the optimal parameter of sharp control is presented. The method takes full advantage of the local characteristic of medical images, and the optimized sharp control parameter is obtained by the iterative computation, and then the cross-section interpolation is performed by the cubic convolution with the optimized parameter in one time.The experimental results show that the method presented in the paper not only can improve the interpolation accuracy effectively, but also is robust.展开更多
A numerical study of the effect of discrete micro tip injection on unsteady tip clearance flow pattern in an isolated axial compressor rotor is presented, intending to better understand the flow mechanism behind stall...A numerical study of the effect of discrete micro tip injection on unsteady tip clearance flow pattern in an isolated axial compressor rotor is presented, intending to better understand the flow mechanism behind stall control measures that act on tip clearance flow. Under the influence of injection the unsteadiness of self-induced tip clearance flow could be weakened. Also the radial migration of tip clearance vortex is confined to a smaller radial extent near the rotor tip and the trajectory of tip clearance flow is pushed more downstream. So the injection is beneficial to improve compressor stability and increase static pressure rise near rotor tip region. The results of injection with different injected mass flow rates show that for the special type of injector adopted in the paper the effect of injection on tip clearance flow may be different according to the relative strength between these two streams of flow. For a fixed injected mass flow rate, reducing the injector area to increase injection velocity can improve the effect of injection on tip clearance flow and thus the compressor stability. A comparison of calculations between single blade passage and multiple blade passages validates the utility of single passage computations to investigate the tip clearance flow for the case without injection and its interaction with injected flow for the case with tip injection.展开更多
文摘Image interpolation of cross-sections is one of the key steps of medical visualization, and the cubic convolution interpolation is usually employed due to its good tradeoff between computational cost and accuracy, however, sometimes its accuracy can still not meet the requirement. Aimed at the problem, in this paper, the interpolation principle based cubic convolution is firstly analyzed systematically, and then essential relationship among the different cubic convolution interpolation methods is clarified. Lastly, a novel cross-section interpolation method for medical images that is based on the optimal parameter of sharp control is presented. The method takes full advantage of the local characteristic of medical images, and the optimized sharp control parameter is obtained by the iterative computation, and then the cross-section interpolation is performed by the cubic convolution with the optimized parameter in one time.The experimental results show that the method presented in the paper not only can improve the interpolation accuracy effectively, but also is robust.
基金This work was supported by National Natural Science Foundation of China with project No.50406027.This support is gratefully acknowledged.
文摘A numerical study of the effect of discrete micro tip injection on unsteady tip clearance flow pattern in an isolated axial compressor rotor is presented, intending to better understand the flow mechanism behind stall control measures that act on tip clearance flow. Under the influence of injection the unsteadiness of self-induced tip clearance flow could be weakened. Also the radial migration of tip clearance vortex is confined to a smaller radial extent near the rotor tip and the trajectory of tip clearance flow is pushed more downstream. So the injection is beneficial to improve compressor stability and increase static pressure rise near rotor tip region. The results of injection with different injected mass flow rates show that for the special type of injector adopted in the paper the effect of injection on tip clearance flow may be different according to the relative strength between these two streams of flow. For a fixed injected mass flow rate, reducing the injector area to increase injection velocity can improve the effect of injection on tip clearance flow and thus the compressor stability. A comparison of calculations between single blade passage and multiple blade passages validates the utility of single passage computations to investigate the tip clearance flow for the case without injection and its interaction with injected flow for the case with tip injection.