Vapor-liquid euilibrium (VLE) for a ternary system of Methyldichlorosilane+methylvinyldichlorosilane+toluene and constituent binary systems were measured at 101.3kPa using a new type of magnetical pump-ebulliometer,Th...Vapor-liquid euilibrium (VLE) for a ternary system of Methyldichlorosilane+methylvinyldichlorosilane+toluene and constituent binary systems were measured at 101.3kPa using a new type of magnetical pump-ebulliometer,The equilibrium conpositions of the vapor phase of binary systems were calculated indirectly from the total pressure-temperature-liquid composition(pTx).The experimental data were correlated with the Wilson and NRTL(non-random two liquid )equations.The parameters of the Wilson moldel were employed to predict the ternary VLE data .The calculated boiling points were in good agreement with the experimental ones.展开更多
The vapor-liquid equilibrium data of four binary systems (acetic acid +p-xylene, methyl acetate +n-propyl acetate, n-propyl acetate +p-xylene and methyl acetate +p-xylene) are measured at 101.33 kPa with Ellis equilib...The vapor-liquid equilibrium data of four binary systems (acetic acid +p-xylene, methyl acetate +n-propyl acetate, n-propyl acetate +p-xylene and methyl acetate +p-xylene) are measured at 101.33 kPa with Ellis equilibrium still, and then both the NRTL and UNIQUAC models are used in combination with the HOC model for correlating and estimating the vapor-liquid equilibrium of these four binary systems. The estimated binary VLE results using correlated parameters agree well with the measured data except the methyl acetate +p-xylene system which easily causes bumping and liquid rushing out of the sampling tap due to their dramatically different boiling points. The correlation results by NRTL and UNIQUAC models have little difference on the average absolute deviations of temperature and composition of vapor phase, and the results by NRTL model are slightly better than those by UNIQUAC model except for the methyl acetate +n-propyl acetate system, for which the latter gives more accurate correlations.展开更多
Green oxidation of cyclohexene using dioxygen as oxidizing agent is highly desirable because of its environmental compatibility and economic impact.Separation of its oxidation products depends on the reliable vaporliq...Green oxidation of cyclohexene using dioxygen as oxidizing agent is highly desirable because of its environmental compatibility and economic impact.Separation of its oxidation products depends on the reliable vaporliquid equilibrium(VLE) data of relevant components,which are still lacking.The VLE data of binary system 1,2-epoxycyclohexane and 2-cyclohexen-1-one under ambient pressure were obtained using an improved VLE equipment EC-2 still in this work.The results showed that this binary system has no azeotropic point.Furthermore,the experimental VLE data were correlated with the Wilson thermodynamic model and the corresponding binary interaction parameters of the model were obtained.The results showed that the VLE data agreed well with the model and passed the thermodynamic consistency test of Herrington.展开更多
基金Supported by the Natural Science Foundation of Jiangxi Province(No.0020019).
文摘Vapor-liquid euilibrium (VLE) for a ternary system of Methyldichlorosilane+methylvinyldichlorosilane+toluene and constituent binary systems were measured at 101.3kPa using a new type of magnetical pump-ebulliometer,The equilibrium conpositions of the vapor phase of binary systems were calculated indirectly from the total pressure-temperature-liquid composition(pTx).The experimental data were correlated with the Wilson and NRTL(non-random two liquid )equations.The parameters of the Wilson moldel were employed to predict the ternary VLE data .The calculated boiling points were in good agreement with the experimental ones.
基金Supported by the Major State Basic Research Development Program of China (2012CB720500), the National Natural Science Foundation of China (U1162202, 61174118) and the Shanghai Leading Academic Discipline Project (B504).
文摘The vapor-liquid equilibrium data of four binary systems (acetic acid +p-xylene, methyl acetate +n-propyl acetate, n-propyl acetate +p-xylene and methyl acetate +p-xylene) are measured at 101.33 kPa with Ellis equilibrium still, and then both the NRTL and UNIQUAC models are used in combination with the HOC model for correlating and estimating the vapor-liquid equilibrium of these four binary systems. The estimated binary VLE results using correlated parameters agree well with the measured data except the methyl acetate +p-xylene system which easily causes bumping and liquid rushing out of the sampling tap due to their dramatically different boiling points. The correlation results by NRTL and UNIQUAC models have little difference on the average absolute deviations of temperature and composition of vapor phase, and the results by NRTL model are slightly better than those by UNIQUAC model except for the methyl acetate +n-propyl acetate system, for which the latter gives more accurate correlations.
基金Supported by Outstanding Personality Innovation Funds of Henan Province (0121001900)
文摘Green oxidation of cyclohexene using dioxygen as oxidizing agent is highly desirable because of its environmental compatibility and economic impact.Separation of its oxidation products depends on the reliable vaporliquid equilibrium(VLE) data of relevant components,which are still lacking.The VLE data of binary system 1,2-epoxycyclohexane and 2-cyclohexen-1-one under ambient pressure were obtained using an improved VLE equipment EC-2 still in this work.The results showed that this binary system has no azeotropic point.Furthermore,the experimental VLE data were correlated with the Wilson thermodynamic model and the corresponding binary interaction parameters of the model were obtained.The results showed that the VLE data agreed well with the model and passed the thermodynamic consistency test of Herrington.