在有铁心永磁直线电机(permanent magnet linear machines,PMLM)初级匝间短路故障分析中,对初级短路环电流的分析十分重要。该文提出采用磁动势–气隙磁导模型与电枢绕组故障等效模型结合的解析方法,计算任意初级位置发生的匝间短路故...在有铁心永磁直线电机(permanent magnet linear machines,PMLM)初级匝间短路故障分析中,对初级短路环电流的分析十分重要。该文提出采用磁动势–气隙磁导模型与电枢绕组故障等效模型结合的解析方法,计算任意初级位置发生的匝间短路故障短路环电流。首先根据永磁、电枢磁动势与开槽情况下的气隙磁导函数分别计算通过短路环的永磁、电枢磁链,然后通过矢量合成法得到短路环中的实际磁链以及瞬时短路电流。基于有限元方法证明解析法的正确性并探究不同短路故障匝数、不同短路故障位置对电机性能如短路环电流、相电流、推力的影响。最后制造一台样机验证有限元分析、解析法计算结果的正确性。展开更多
A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accu...A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accurately,we establish corresponding equivalent mathematical model considering magnetic leakage based on magnetic circuit and circuit dualistic transformation method.The distribution of magnetic leakage field of each winding is analyzed qualitatively,and the analytical calculation formulas of magnetizing inductance and leakage inductance of each winding are derived.Based on this,the analytical calculation formulas of short-circuit impedance and winding current of CRT under different working conditions are derived.The field-circuit coupling finite element model of the magnetic integrated CRT is established to simulate the current of each winding under different working conditions.The results show that the analytical calculation results of each winding current have good consistency with the finite element calculation results,indicating the validity of CRT equivalent mathematical model and correctness of the analytical formulas of leakage inductance,short-circuit impedance and winding current of CRT.The working winding current of CRT is increasing gradually with the operation of control winding in turn to realise the transition of CRT compensation capacity from zero to a rated value.展开更多
文摘在有铁心永磁直线电机(permanent magnet linear machines,PMLM)初级匝间短路故障分析中,对初级短路环电流的分析十分重要。该文提出采用磁动势–气隙磁导模型与电枢绕组故障等效模型结合的解析方法,计算任意初级位置发生的匝间短路故障短路环电流。首先根据永磁、电枢磁动势与开槽情况下的气隙磁导函数分别计算通过短路环的永磁、电枢磁链,然后通过矢量合成法得到短路环中的实际磁链以及瞬时短路电流。基于有限元方法证明解析法的正确性并探究不同短路故障匝数、不同短路故障位置对电机性能如短路环电流、相电流、推力的影响。最后制造一台样机验证有限元分析、解析法计算结果的正确性。
基金Weinan Science and Technology Plan Project(No.2020ZDYF-JCYJ-177)General Special Scientific Research Projects of Education Department of Shaanxi Provincial Government(No.21JK0582)+2 种基金Young and Middle-aged Scientific and Technological Talents Project of Shaanxi Railway Institute(No.KJRC202001)Scientific Research Fund Project of Shaanxi Railway Institute(No.KY2021-34)Science and Technology Innovation Team of Shaanxi Railway Institute(No.KJTD201901)。
文摘A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accurately,we establish corresponding equivalent mathematical model considering magnetic leakage based on magnetic circuit and circuit dualistic transformation method.The distribution of magnetic leakage field of each winding is analyzed qualitatively,and the analytical calculation formulas of magnetizing inductance and leakage inductance of each winding are derived.Based on this,the analytical calculation formulas of short-circuit impedance and winding current of CRT under different working conditions are derived.The field-circuit coupling finite element model of the magnetic integrated CRT is established to simulate the current of each winding under different working conditions.The results show that the analytical calculation results of each winding current have good consistency with the finite element calculation results,indicating the validity of CRT equivalent mathematical model and correctness of the analytical formulas of leakage inductance,short-circuit impedance and winding current of CRT.The working winding current of CRT is increasing gradually with the operation of control winding in turn to realise the transition of CRT compensation capacity from zero to a rated value.