This paper presents methods for determining the basic geometry of end-gear with arc tooth external diameter, width of tooth, end module, number of teeth, pressure angle, tooth, tooth clearance parameters; at the same ...This paper presents methods for determining the basic geometry of end-gear with arc tooth external diameter, width of tooth, end module, number of teeth, pressure angle, tooth, tooth clearance parameters; at the same time gives the tooth bearing strength calculation method, and the formulas to calculate the tooth shear stress, surface stress and bolt fastening force of equivalent stress is established; finally write the software error simulation analysis.展开更多
The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere's Law, and the environm...The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere's Law, and the environmental impact factors of the fields were evaluated. By optimizing the phase sequence, the frequency electric intensity and magnetic field strength can be reduced. Within a distance of 25 m from the center of the transmission line, the power frequency electric intensity and magnetic field strength fall off sharply with the distance increase. Finally, the best phase sequence and the minimum ground clearance of the transmission lines were obtained to meet the requirements of the least impact on envionment.展开更多
文摘This paper presents methods for determining the basic geometry of end-gear with arc tooth external diameter, width of tooth, end module, number of teeth, pressure angle, tooth, tooth clearance parameters; at the same time gives the tooth bearing strength calculation method, and the formulas to calculate the tooth shear stress, surface stress and bolt fastening force of equivalent stress is established; finally write the software error simulation analysis.
文摘The strength of the power frequency electric intensity and magnetic field of the 500-kV double circuit transmission lines was calculated by using the equivalent charge method and the Ampere's Law, and the environmental impact factors of the fields were evaluated. By optimizing the phase sequence, the frequency electric intensity and magnetic field strength can be reduced. Within a distance of 25 m from the center of the transmission line, the power frequency electric intensity and magnetic field strength fall off sharply with the distance increase. Finally, the best phase sequence and the minimum ground clearance of the transmission lines were obtained to meet the requirements of the least impact on envionment.