To match the large power long pulse neutral beam injectors for HL-2A Tokarnak,a circular magnetic multipole line-cusp ion source(namely a bucket ion source)has been designed.The arc chamber of this ion source is a wat...To match the large power long pulse neutral beam injectors for HL-2A Tokarnak,a circular magnetic multipole line-cusp ion source(namely a bucket ion source)has been designed.The arc chamber of this ion source is a water-cooled,stainless-steel cylinder 26cm in diameter,4mm thick,and 24cm long.So far,many arc discharge experiments on this ion source have demonstrated that the plasma density has been 0.24A/cm^2,for 3 seconds duration, within 5%—7% plasma uniformity,and 3 seconds maximum pulse.Arc discharge characteristics,such as the gas pressure dependence and filaments arrangements dependence have been studied experimentally and theoretically in this paper.展开更多
In this study, the Pb/U fractionation between zircon and uraninite during femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry (fs-LA-ICP-MS) analysis was studied in detail. The results show signi...In this study, the Pb/U fractionation between zircon and uraninite during femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry (fs-LA-ICP-MS) analysis was studied in detail. The results show significant Pb/U fractionation between zircon and uraninite during fs-LA-ICP-MS analysis that when calibrated against the zircon standard M257, the obtained U-Pb age of the Chinese national uraninite standard GBW04420 is 17% older than the recommended value. Thus, the accurate in-situ U-Pb dating of uraninite by LA-ICP-MS requires matrix-matched external standards for calibration. Uraninite in thin sections of two U-mineralized leucogranite from the Gaudeanmus in Namibia was analyzed by a fs-LA-ICP-MS equipped with a Signal Smooth Device (SSD), using laser spot and frequency of 10 μm and 1 Hz, respectively. When calibrated using GBW04420 as the external standard, two samples give weighted mean 2066pb/238U ages of 504±3 Ma (2σ, n=21) and 503±3 Ma (2σ, n=22), and only one of two samples yields a concordia U-Pb age of 507±1 Ma (2or, n=21). These results are consistent with ID-TIMS U-Pb ages of 509±1 and 508±12 Ma and are also indistinguishable from zircon U-Pb upper intercept ages of 506±33 Ma (2σ, n=29) and 501±51 Ma (2σ, n=29). The present study shows that in-situ U-Pb dating of uraninite can deliver more reliable formation ages of the deposit than dating coeval high-U zircon because the latter commonly suffer significant Pb loss after formation. Our results confirm that GBW04420 is an ideal matrix matching standard for in-situ U-Pb dating of uraninite.展开更多
文摘To match the large power long pulse neutral beam injectors for HL-2A Tokarnak,a circular magnetic multipole line-cusp ion source(namely a bucket ion source)has been designed.The arc chamber of this ion source is a water-cooled,stainless-steel cylinder 26cm in diameter,4mm thick,and 24cm long.So far,many arc discharge experiments on this ion source have demonstrated that the plasma density has been 0.24A/cm^2,for 3 seconds duration, within 5%—7% plasma uniformity,and 3 seconds maximum pulse.Arc discharge characteristics,such as the gas pressure dependence and filaments arrangements dependence have been studied experimentally and theoretically in this paper.
基金supported by the National Natural Science Foundation of China(Grant Nos.41203027 and 41473031)the State Administration of Foreign Expert Affairs of China(Grant No.B07039)the Special Fund for Basic Scientific Research of Central Colleges,China University of Geosciences(Wuhan)(Grant No.CUGL140403)
文摘In this study, the Pb/U fractionation between zircon and uraninite during femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry (fs-LA-ICP-MS) analysis was studied in detail. The results show significant Pb/U fractionation between zircon and uraninite during fs-LA-ICP-MS analysis that when calibrated against the zircon standard M257, the obtained U-Pb age of the Chinese national uraninite standard GBW04420 is 17% older than the recommended value. Thus, the accurate in-situ U-Pb dating of uraninite by LA-ICP-MS requires matrix-matched external standards for calibration. Uraninite in thin sections of two U-mineralized leucogranite from the Gaudeanmus in Namibia was analyzed by a fs-LA-ICP-MS equipped with a Signal Smooth Device (SSD), using laser spot and frequency of 10 μm and 1 Hz, respectively. When calibrated using GBW04420 as the external standard, two samples give weighted mean 2066pb/238U ages of 504±3 Ma (2σ, n=21) and 503±3 Ma (2σ, n=22), and only one of two samples yields a concordia U-Pb age of 507±1 Ma (2or, n=21). These results are consistent with ID-TIMS U-Pb ages of 509±1 and 508±12 Ma and are also indistinguishable from zircon U-Pb upper intercept ages of 506±33 Ma (2σ, n=29) and 501±51 Ma (2σ, n=29). The present study shows that in-situ U-Pb dating of uraninite can deliver more reliable formation ages of the deposit than dating coeval high-U zircon because the latter commonly suffer significant Pb loss after formation. Our results confirm that GBW04420 is an ideal matrix matching standard for in-situ U-Pb dating of uraninite.