A maximally flat FIR filter design method based on explicit formulas combined with simulated annealing and random search was presented. Utilizing the explicit formulas to calculate the ini- tial values, the firate-wor...A maximally flat FIR filter design method based on explicit formulas combined with simulated annealing and random search was presented. Utilizing the explicit formulas to calculate the ini- tial values, the firate-word-length FIR filter design problem was converted into optimization of the filter coefficients, An optimization method combined with local discrete random search and simulated annealing was proposed, with the result of optimum solution in the sense of Chebyshev approximation. The proposed method can simplify the design process of FIR filter and reduce the calculation burden. The simulation result indicates that the proposed method is superior to the traditional round off method and can reduce the value of the objective function to 41%~74%.展开更多
Current health monitoring systems often do not concern about the needs of the elderly,leading to inaccurate health status monitoring and delayed treatment for emergency health conditions.Similarly,they do not consider...Current health monitoring systems often do not concern about the needs of the elderly,leading to inaccurate health status monitoring and delayed treatment for emergency health conditions.Similarly,they do not consider the variable factors affecting each patient,resulting in discrepancies between the measured values and real health status.To solve the problems,we propose a new health monitoring system with physiological parameter measurement,correction,and feedback.The study collects clinical samples of the elderly to formulate regression equations and statistical models for analyzing the relationship between gender,age,measurement time,and physical signs.After multiple adjustments to measurements of physical signs,the correction algorithm compares the data with a standard value.The process significantly reduces the risk of misjudgment while matching users’health status more accurately.The application case of this paper proves the validity of the method for measuring and correcting heart rate results in the elderly and presents a specific correction procedure.Additionally,the correction algorithm provides a scientific basis for eliminating or modifying other influencing factors in future health monitoring studies.展开更多
文摘A maximally flat FIR filter design method based on explicit formulas combined with simulated annealing and random search was presented. Utilizing the explicit formulas to calculate the ini- tial values, the firate-word-length FIR filter design problem was converted into optimization of the filter coefficients, An optimization method combined with local discrete random search and simulated annealing was proposed, with the result of optimum solution in the sense of Chebyshev approximation. The proposed method can simplify the design process of FIR filter and reduce the calculation burden. The simulation result indicates that the proposed method is superior to the traditional round off method and can reduce the value of the objective function to 41%~74%.
基金This work was supported by the National Natural Science Foundation of China(No.51804014).
文摘Current health monitoring systems often do not concern about the needs of the elderly,leading to inaccurate health status monitoring and delayed treatment for emergency health conditions.Similarly,they do not consider the variable factors affecting each patient,resulting in discrepancies between the measured values and real health status.To solve the problems,we propose a new health monitoring system with physiological parameter measurement,correction,and feedback.The study collects clinical samples of the elderly to formulate regression equations and statistical models for analyzing the relationship between gender,age,measurement time,and physical signs.After multiple adjustments to measurements of physical signs,the correction algorithm compares the data with a standard value.The process significantly reduces the risk of misjudgment while matching users’health status more accurately.The application case of this paper proves the validity of the method for measuring and correcting heart rate results in the elderly and presents a specific correction procedure.Additionally,the correction algorithm provides a scientific basis for eliminating or modifying other influencing factors in future health monitoring studies.