A 2MeV thermionic cathode test stand was established to meet the requirement of the large area thermionic cathode system.A 100ram in diameter type'B'thermionic dispenser cathode was developed.A 1000A emission ...A 2MeV thermionic cathode test stand was established to meet the requirement of the large area thermionic cathode system.A 100ram in diameter type'B'thermionic dispenser cathode was developed.A 1000A emission current was produced at the voltage of the diode about 1.8MV,the pulse width about 90ns(FWHM),and the cathode temperature about 1350℃.The emission current density is 12A/cm^2.The results indicate that a large area thermionic cathode which produces high quality and high current electron beams is visible.The results also indicate that the ability of cathode emission relies on the diode-vacuum and cathode-temperature.展开更多
在Through changing soaking temperature and soaking time, austenite grain growth behavior of X80 pipeline steel under different heating conditions was studied. Relationships of average grain size to soaking temperature...在Through changing soaking temperature and soaking time, austenite grain growth behavior of X80 pipeline steel under different heating conditions was studied. Relationships of average grain size to soaking temperature and time were obtained respectively. The results show that the prior austenite grains grow with the increase of soaking temperature and time. When soaking temperature is lower than 1 180 ℃, austenite grain size and growth rate are small; when it higher than 1 200 ℃, austenite grains grow rapidly and abnormal grain growth appears. For soaking at 1 180 ℃, austenite grain growth rate is initially high and then decreases when soaking time exceeds 1 h.展开更多
文摘A 2MeV thermionic cathode test stand was established to meet the requirement of the large area thermionic cathode system.A 100ram in diameter type'B'thermionic dispenser cathode was developed.A 1000A emission current was produced at the voltage of the diode about 1.8MV,the pulse width about 90ns(FWHM),and the cathode temperature about 1350℃.The emission current density is 12A/cm^2.The results indicate that a large area thermionic cathode which produces high quality and high current electron beams is visible.The results also indicate that the ability of cathode emission relies on the diode-vacuum and cathode-temperature.
基金Item Sponsored by National Key Technology Research and Development Program of China (2006BAE03A15)Natural Science Foundation of Yunnan Province of China (2006E0017Q)
文摘在Through changing soaking temperature and soaking time, austenite grain growth behavior of X80 pipeline steel under different heating conditions was studied. Relationships of average grain size to soaking temperature and time were obtained respectively. The results show that the prior austenite grains grow with the increase of soaking temperature and time. When soaking temperature is lower than 1 180 ℃, austenite grain size and growth rate are small; when it higher than 1 200 ℃, austenite grains grow rapidly and abnormal grain growth appears. For soaking at 1 180 ℃, austenite grain growth rate is initially high and then decreases when soaking time exceeds 1 h.