SMART (system-integrated modular advanced reactor) is a small-sized advanced integral reactor with a rated thermal power of 330 MW. It can produce 100 MW of electricity, or 90 MW of electricity and 40,000 t of desal...SMART (system-integrated modular advanced reactor) is a small-sized advanced integral reactor with a rated thermal power of 330 MW. It can produce 100 MW of electricity, or 90 MW of electricity and 40,000 t of desalinated water concurrently, which is sufficient for 100,000 residents. SMART technology is a sensible mixture of new innovative design features and proven technologies through a PWR. The enhancement of safety and reliability is realized by incorporating inherent safety features and reliable passive safety systems. The improvement in the economics is achieved through system simplification, component modularization, construction time reduction, and increased plant availability. All technologies and design features implemented into SMART have been proven in industries and/or qualified through the SMART design verification program including comprehensive test and experiments. The full scope of the safety analyses carried out to confirm that the inherent safety-improvement design characteristics and safety systems of SMART ensure reactor safety. After a thorough licensing review, SDA (standard design approval) for SMART was granted on July 4th, 2012 by the Korea NSSC (Nuclear Safety and Security Commission). This marks the first license for an integral-type reactor in the world. This paper presents the SMART characteristics, safety features and technology validation. The licensing process of SMART is also described.展开更多
Based on some assumptions,the dynamic governing equation of anchorage system is established.The calculation formula of natural frequency and the corresponding vibration mode are deduced.Besides,the feasibility of the ...Based on some assumptions,the dynamic governing equation of anchorage system is established.The calculation formula of natural frequency and the corresponding vibration mode are deduced.Besides,the feasibility of the theoretical method is verified by using a specific example combined with other methods.It is found that the low-order natural frequency corresponds to the first mode of vibration,and the high-order natural frequency corresponds to the second mode of vibration,while the third mode happens only when the physical and mechanical parameters of anchorage system meet certain conditions.With the increasing of the order of natural frequency,the influence on the dynamic mechanical response of anchorage system decreases gradually.Additionally,a calculating method,which can find the dangerous area of anchorage engineering in different construction sites and avoid the unreasonable design of anchor that may cause resonance,is proposed to meet the seismic precautionary requirements.This method is verified to be feasible and effective by being applied to an actual project.The study of basic dynamic features of anchorage system can provide a theoretical guidance for anchor seismic design and fast evaluation of anchor design scheme.展开更多
文摘SMART (system-integrated modular advanced reactor) is a small-sized advanced integral reactor with a rated thermal power of 330 MW. It can produce 100 MW of electricity, or 90 MW of electricity and 40,000 t of desalinated water concurrently, which is sufficient for 100,000 residents. SMART technology is a sensible mixture of new innovative design features and proven technologies through a PWR. The enhancement of safety and reliability is realized by incorporating inherent safety features and reliable passive safety systems. The improvement in the economics is achieved through system simplification, component modularization, construction time reduction, and increased plant availability. All technologies and design features implemented into SMART have been proven in industries and/or qualified through the SMART design verification program including comprehensive test and experiments. The full scope of the safety analyses carried out to confirm that the inherent safety-improvement design characteristics and safety systems of SMART ensure reactor safety. After a thorough licensing review, SDA (standard design approval) for SMART was granted on July 4th, 2012 by the Korea NSSC (Nuclear Safety and Security Commission). This marks the first license for an integral-type reactor in the world. This paper presents the SMART characteristics, safety features and technology validation. The licensing process of SMART is also described.
基金Projects(51308273,41372307,41272326)supported by the National Natural Science Foundation of ChinaProject(20090211110016)supported by Specialized Research Fund for the Doctoral Program of Higher Education of ChinaProject(2010(A)06-b)supported by Science and Technology Fund of Yunan Provincial Communication Department,China
文摘Based on some assumptions,the dynamic governing equation of anchorage system is established.The calculation formula of natural frequency and the corresponding vibration mode are deduced.Besides,the feasibility of the theoretical method is verified by using a specific example combined with other methods.It is found that the low-order natural frequency corresponds to the first mode of vibration,and the high-order natural frequency corresponds to the second mode of vibration,while the third mode happens only when the physical and mechanical parameters of anchorage system meet certain conditions.With the increasing of the order of natural frequency,the influence on the dynamic mechanical response of anchorage system decreases gradually.Additionally,a calculating method,which can find the dangerous area of anchorage engineering in different construction sites and avoid the unreasonable design of anchor that may cause resonance,is proposed to meet the seismic precautionary requirements.This method is verified to be feasible and effective by being applied to an actual project.The study of basic dynamic features of anchorage system can provide a theoretical guidance for anchor seismic design and fast evaluation of anchor design scheme.